NA 5150-9-960Recalls & reported problems
Stryker GmbH · Sterile Wrist Kit · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327093308), received between Jul 31, 2020 and Jul 31, 2020 — classified as 1 malfunction.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Fracture1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 31, 2020Fracture; Fracture
THE SURGEON PLACED 2X 3MM APEX PINS IN THE LEFT 2ND METACARPAL AND MIDWAY IN THE RADIUS. THE TRIAX MONOTUBE FROM A STERILE WRIST KIT WAS PLACED OVER THE PINS. THE SURGEON REDUCED THE FRACTURE AND TIGHTENED THE BOLTS ON THE PROXIMAL PIN CLAMP FOLLOWED BY THE BOLTS ON THE DISTAL PIN CLAMP. THE PIN CLAMP ON THE DISTAL PINS WAS LOOSENED TO MAKE FURTHER ADJUSTMENTS THEN ALL BOLTS WERE TIGHTENED AGAIN. ONCE THE SURGEON TRIED TO LOOSEN THE FLEXION/EXTENSION CONTROL ON THE DISTAL PIN CLAMP, THE BOLT BROKE. A PORTION OF THE BOLT REMAINED IN THE PIN CLAMP AND ANOTHER PORTION ALONG WITH THE HEAD OF THE BOLT WAS SEPARATED FROM THE CLAMP. THE 4 APEX PINS WERE REMOVED AND SURGEON SPLINTED THE PATIENT UNDER X-RAY.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Known Impact Or Consequence To Patient
MAUDE report 10349716 ↗
Other PIN, FIXATION, THREADED devices
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall2 reports
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall0 reports
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall0 reports
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall0 reports
- APEX 5038-1-080Stryker GmbH · PIN, FIXATION, THREADED48 reports
- Agee Digit Widget® DWD-232Hand Biomechanics Lab Inc · Pin, Fixation, Threaded32 reports
- SPATIAL FRAME 71070720Smith & Nephew, Inc. · PIN, FIXATION, THREADED15 reports
- APEX 5038-2-110Stryker GmbH · PIN, FIXATION, THREADED11 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page