Aero-C 48894050Recalls & reported problems
Stryker Corporation · Cervical Cage · Class 2 · Implant
All models of Aero-C (8)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327124811), received between Mar 29, 2017 and Mar 29, 2017 — classified as 1 malfunction.
The most frequently reported specific device problem is “Difficult to Insert” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Difficult to Insert1
- Disassembly1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 29, 2017Disassembly; Difficult to Insert; Disassembly
IT WAS REPORTED THAT; THE ANCHOR OF THE CAGE WOULD NOT FULLY INSERT INTO BONE. THE PILOT CUTTER WOULD NOT SEAT ALL THE WAY INTO BONE EITHER. THE SURGEON ATTEMPTED TO DRIVE THE CUTTER SEVERAL TIMES AND WE TRIED MULTIPLE DIFFERENT PILOT CUTTERS. THEN HE ATTEMPTED TO DRIVE THE ANCHOR INTO VERTEBRAL BODY AND IT STOPPED AFTER DRIVING THROUGH BONE APPROXIMATELY 85% OF THE WAY. WE ATTEMPTED SEVERAL DIFFERENT TAMPS AS WELL AS THE FREE HAND TAMP. AFTER TRYING FOR 5-10 MINUTES THE SURGEON WAS NOT WILLING TO APPLY ANY MORE FORCE VIA MALLETING THE ANCHOR. THE SURGEON WAS MALLETING AT A FORCE GREATER THAN NORMAL FOR CERVICAL IMPLANT PLACEMENT. THE BLADE WAS LEFT WITHOUT BEING FULLY INSERTED. THE ASSOCIATED SURGICAL DELAY WAS 15 MINUTES.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6443458 ↗
Other Intervertebral fusion device with bone graft, cervical devices
- EIT CIF cage CUI8070SEIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Cervical1 recall4 reports
- ROI-C MC1005TLDR Spine Usa, Inc. · Intervertebral Fusion Device With Bone Graft, Cervical54 reports
- EIT CIF cage CUI8060LEIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Cervical1 recall1 report
- CONSTRUX - MINI PTC 37-5012SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-6211SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-7308SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-9207SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-6106SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page