VertaPlex HV 0406622015Recalls & reported problems

Stryker Corporation · 20 Gram Twin Pack (1/2 dose) · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
17
Deaths reported
1
Injuries reported
5
Recalls naming it
0

Summary

The FDA's MAUDE database contains 17 adverse event reports that list this exact device (DI 07613327170559), received between Nov 30, 2021 and Jul 22, 2026 — classified as 1 death, 5 injuries, 11 malfunctions.

The most frequently reported specific device problem is “Entrapment of Device” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 3 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Entrapment of Device3
  • Migration3
  • Adverse Event Without Identified Device or Use Problem2
  • Device Ingredient or Reagent Problem2
  • Expiration Date Error2
  • Improper or Incorrect Procedure or Method2
  • No Apparent Adverse Event2
  • Failure to Infuse1

Patient problems

  • No Clinical Signs, Symptoms or Conditions10
  • Foreign Body In Patient6
  • Hypoxia2
  • Anaphylactic Shock1
  • Embolism/Embolus1

Recent adverse event reports

The 17 most recent of 17 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 22, 2026Improper or Incorrect Procedure or Method

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25907801 ↗
  • InjuryApr 30, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT EXPERIENCED PROBABLE GRADE 3 ANAPHYLACTIC SHOCK DUE TO CEMENT, SYMPTOMS INCLUDED WIDESPREAD HIVES, HYPOTENSION AND DESATURATION. MEDICAL INTERVENTION WAS REQUIRED AND THE PATIENT WAS TRANSFERRED TO THE INTENSIVE CARE UNIT FOR MONITORING. THE PATIENT WAS DISCHARGED FROM HOSPITAL THE FOLLOWING DAY AND RETURNED HOME WITHOUT COMPLICATIONS. ON DAY 1, THE PATIENT WAS ABLE TO GET OUT OF BED. POSTURAL REHABILITATION BEGAN. THE PATIENT IS WALKING AND CAN SIT UP EASILY.

    Patient problems: Anaphylactic Shock; Hypoxia

    MAUDE report 25042563 ↗
  • InjuryMar 3, 2026Migration

    NO NEW INFORMATION.

    Patient problems: Foreign Body In Patient; Hypoxia

    MAUDE report 24500679 ↗
  • DeathNov 14, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT DURING A SPINAL SURGICAL PROCEDURE THE CEMENT LEAKED INTO A VEIN. THE CEMENT USED WAS NOT REPORTED TO HAVE MALFUNCTIONED. IT WAS FURTHER REPORTED THAT THE PATIENT HAD A PATHOLOGIC FRACTURE AT T10 WITH CORD COMPRESSION, THE PATIENT HAD MULTIPLE METASTATIC LESIONS AT T8, T9 AND L2. IT WAS REPORTED THAT THE CEMENT PASSED THROUGH THE HEART AND WAS FLATTENED OUT ALONG THE PULMONARY ARTERY EXTENDING BOTH LEFT AND RIGHT. THE PATIENT DIED FOLLOWING THIS PROCEDURE.

    Patient problems: Embolism/Embolus

    MAUDE report 23555265 ↗
  • MalfunctionOct 28, 2025Device Ingredient or Reagent Problem; Device Ingredient or Reagent Problem

    THIS RECORD IS A CONSOLIDATION OF RECORDS SUMMARIZED AS A PART OF THE FDA VOLUNTARY MALFUNCTION SUMMARY REPORTING PROGRAM. EVENTS OCCURRED BETWEEN (B)(6) 2025 - (B)(6) 2025. THIS REPORT SUMMARIZES 1 EVENT - FOR THE FAILURE: DEVICE INGREDIENT OR REAGENT PROBLEM. - 1 EVENT HAD NO HEALTH CONSEQUENCES OR IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23399853 ↗
  • MalfunctionJul 30, 2025Expiration Date Error; Expiration Date Error

    IT WAS REPORTED THAT EXPIRED CEMENT WAS USED DURING A SURGICAL PROCEDURE. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A CLINICALLY SIGNIFICANT DELAY; NO ADVERSE CONSEQUENCES OR MEDICAL INTERVENTION WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22665607 ↗
  • MalfunctionJul 29, 2025Improper or Incorrect Procedure or Method; Improper or Incorrect Procedure or Method

    THIS REPORT SUMMARIZES 1 EVENT FOR THE FAILURE: IMPROPER OR INCORRECT PROCEDURE OR METHOD. 1 EVENT HAD NO HEALTH CONSEQUENCES OR IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22648117 ↗
  • MalfunctionJul 14, 2025Entrapment of Device; Entrapment of Device

    IT WAS REPORTED THAT DUE TO THE CEMENT HARDENING, A PORTION OF THE PEAK SHEATH WAS LEFT IN THE PATIENT. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A CLINICALLY SIGNIFICANT DELAY; NO MEDICAL INTERVENTION OR ADVERSE CONSEQUENCES WERE REPORTED.

    Patient problems: Foreign Body In Patient

    MAUDE report 22495687 ↗
  • InjuryNov 6, 2024Entrapment of Device; Entrapment of Device

    NO NEW INFORMATION.

    Patient problems: Foreign Body In Patient

    MAUDE report 20622996 ↗
  • MalfunctionOct 21, 2024Device Ingredient or Reagent Problem; Device Ingredient or Reagent Problem

    THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT IN WHICH THE DEVICE REPORTEDLY HAD A DEVICE INGREDIENT OR REAGENT PROBLEM. 1 EVENT HAD PATIENT INVOLVEMENT, NO PATIENT IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20500627 ↗
  • InjuryJun 14, 2024Migration; Migration

    IT WAS REPORTED THAT DURING A KYPHOPLASTY PROCEDURE, CEMENT EXTRAVASATED INTO THE PATIENTS LUNG. IT WAS ALSO REPORTED THAT FRAGMENTS OF THE CEMENT COULD NOT BE REMOVED. IT WAS FURTHER REPORTED THAT THERE WERE NO ADVERSE CONSEQUENCES AS A RESULT OF THIS EVENT AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: Foreign Body In Patient

    MAUDE report 19542984 ↗
  • MalfunctionNov 22, 2023Expiration Date Error; Expiration Date Error

    IT WAS REPORTED THAT DURING A SURGICAL PROCEDURE, THE SURGEON KNOWINGLY USED EXPIRED PRODUCT. IT WAS ALSO REPORTED THERE WERE NO DELAYS AND NO ADVERSE CONSEQUENCES AS A RESULT OF THIS EVENT. IT WAS FURTHER REPORTED THAT THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18192446 ↗
  • MalfunctionMay 19, 2023No Apparent Adverse Event; No Apparent Adverse Event

    IT WAS REPORTED THAT DURING A SURGICAL PROCEDURE, IT WAS NOTED THAT THE SURGEON USED EXPIRED PRODUCT. THIS REPORT IS ADDRESSING THE STERILITY RISK ASSOCIATED WITH SUCH AN EVENT. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16961399 ↗
  • InjuryMay 7, 2022Improper Flow or Infusion; Thickening of Material; Improper Flow or Infusion; Thickening of Material

    IT WAS REPORTED THAT DURING A SURGICAL PROCEDURE, THE CEMENT VISCOSITY WAS TOO HIGH AND CAUSED THE DELIVERY CANNULA TO GET STUCK IN THE PATIENT. IT WAS FURTHER REPORTED THAT THE EVENT CAUSED A DELAY LEADING TO PROLONGED SURGICAL TIME AND LONGER TIME UNDER ANESTHESIA FOR THE PATIENT. IT WAS ALSO REPORTED THAT THE SURGEON PERFORMED A SPONDYLODESIS (SPINAL FUSION) TO COMPLETE THE PROCEDURE. IT WAS FURTHER REPORTED THAT A PART OF THE GUIDE SLEEVE REMAINED IN THE PATIENT. IT WAS ALSO REPORTED THAT THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: Foreign Body In Patient

    MAUDE report 14322672 ↗
  • MalfunctionApr 15, 2022Entrapment of Device; Failure to Infuse; Entrapment of Device; Failure to Infuse

    IT WAS REPORTED THAT DURING A SURGICAL PROCEDURE, THE CEMENT SET TOO QUICKLY. IT WAS ALSO REPORTED THAT THE CEMENT DELIVERY NEEDLE WAS STUCK IN THE PATIENT. IT WAS FURTHER REPORTED THAT A DECISION WAS MADE TO LEAVE THE NEEDLE IN THE PATIENT. IT WAS ALSO REPORTED THERE WERE NO DELAYS AND NO ADVERSE CONSEQUENCES AS A RESULT OF THIS EVENT. IT WAS FURTHER REPORTED THAT THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: Foreign Body In Patient; No Clinical Signs, Symptoms or Conditions

    MAUDE report 14117525 ↗
  • MalfunctionFeb 3, 2022No Apparent Adverse Event; No Apparent Adverse Event

    IT WAS REPORTED THAT AFTER A SURGICAL PROCEDURE, IT WAS NOTED THAT THE SURGEON KNOWINGLY USED EXPIRED PRODUCT. IT WAS ALSO REPORTED THERE WERE NO DELAYS AND NO ADVERSE CONSEQUENCES AS A RESULT OF THIS EVENT. IT WAS FURTHER REPORTED THAT THE PROCEDURE WAS COMPLETED SUCCESSFULLY. THIS REPORT IS ADDRESSING THE STERILITY RISK ASSOCIATED WITH SUCH AN EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13446694 ↗
  • MalfunctionNov 30, 2021Migration; Migration

    IT WAS REPORTED THAT DURING A SURGICAL PROCEDURE, IT WAS NOTED THAT EXTRAVASATION OF CEMENT OCCURRED. IT WAS ALSO REPORTED THERE WERE NO DELAYS AND NO ADVERSE CONSEQUENCES AS A RESULT OF THIS EVENT. IT WAS FURTHER REPORTED THAT THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12893752 ↗

FDA clearance and classification

The FDA regulates product code NDN (cement, bone, vertebroplasty) under 21 CFR 888.3027 as a Class II device. 21 CFR 888.3027 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the VertaPlex HV 0406622015

Has the VertaPlex HV 0406622015 been recalled?

No FDA recall record in our data names this exact device identifier (DI 07613327170559), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the VertaPlex HV 0406622015?

The FDA's MAUDE database lists 17 adverse event reports for this device, received between Nov 30, 2021 and Jul 22, 2026. In those reports, the most common specific device problems are “Entrapment of Device” (3), “Migration” (3) and “Device Ingredient or Reagent Problem” (2); the most common patient problems are “Foreign Body In Patient” (6), “Hypoxia” (2) and “Anaphylactic Shock” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the VertaPlex HV 0406622015?

1 report is classified as a death, 5 as injuries and 11 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the VertaPlex HV 0406622015 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Safe: it poses no known hazards in any MRI environment.

Who makes the VertaPlex HV 0406622015, and is it still sold?

The FDA's device database lists Stryker Corporation as the company responsible for it (brand VertaPlex HV, model 0406622015). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.