Trident II 702-04-60G (UDI 07613327343908)Recalls & reported problems

Howmedica Osteonics Corp. · TRIDENT II TRITANIUM CLUSTER 60G · Class 2 · Implant

All models of TRIDENT II (42)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 07613327343908), received between Oct 30, 2019 and Nov 15, 2024 — classified as 6 injuries.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 2 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Insufficient Device Problem Information1
  • Loss of Osseointegration1
  • Malposition of Device1
  • Osseointegration Problem1
  • Positioning Problem1

Patient problems

  • Inadequate Osseointegration2
  • Foreign Body Reaction1
  • Injury1
  • Joint Dislocation1
  • Pain1
  • Swelling/ Edema1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 15, 2024Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information

    THE FOLLOWING WAS REPORTED - THE PATIENT PRESENTED TO THE SURGEON WITH HIP PAIN AND SWELLING AND THE SURGEON THEN DECIDED THE PATIENT REQUIRED A WASH OUT AND EXAMINATION UNDER ANAESTHETIC IN THEATRE. ON EXPLANTATION, SEVERAL MARKS WERE OBSERVED ON THE X3 INSERT. ON DISLOCATION OF THE IMPLANTED PRIMARY HIP, THE SURGEON NOTICED SEVERAL LINEAR MARKS ON THE FLOOR OF THE X3 INSERT AND ON REMOVAL IT WAS NOTICED THAT THERE WAS A LINEAR MARK ON THE BIOLOX HEAD. THE SURGEON DECIDED THAT THE SHELL NEEDED TO BE REPLACED, SO THE SHELL IN SITU WAS EXPLANTED AND REPLACED WITH A TRIDENT 2 REVISION SHELL AND TWO SCREWS. THE LINER WAS REPLACED AS WAS THE 36MM BIOLOX HEAD.

    Patient problems: Pain; Swelling/ Edema

    MAUDE report 20695729 ↗
  • InjuryNov 7, 2024Loss of Osseointegration; Loss of Osseointegration

    CUP CAME LOOSE FROM ORIGINAL TOTAL HIP SURGERY DONE ON (B)(6) 2021. REVISION OF CUP, HEAD & SLEEVE, AND LINER DONE ON (B)(6) 2024.

    Patient problems: Inadequate Osseointegration

    MAUDE report 20635732 ↗
  • InjuryDec 15, 2023Osseointegration Problem; Osseointegration Problem

    REVISED A RIGHT HIP CUP, LINER AND HEAD DUE TO CUP LOOSENING.

    Patient problems: Inadequate Osseointegration

    MAUDE report 18340962 ↗
  • InjuryJul 27, 2022Positioning Problem; Positioning Problem

    PATIENT RETURNED TO THEATRE FOLLOWING PRIMARY HIP JOINT REPLACEMENT DUE TO HEAD DISLOCATED OUT OF LINER (SAME DAY). CUP REPOSITIONED, 10 DEG LINER EXCHANGED FOR MDM, HEAD REVISED TO ORTHINOX HEAD AND ACCOLADE II STEM REMAINED.

    Patient problems: Joint Dislocation

    MAUDE report 15109731 ↗
  • InjuryAug 16, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AS REPORTED: "SURGEON CONTACT ME REPORTING SUSPECTED METALOSIS AND SOFT TISSUE ABNORMALITY." PATIENT WAS REVISED.

    Patient problems: Foreign Body Reaction

    MAUDE report 12325208 ↗
  • InjuryOct 30, 2019Malposition of Device; Malposition of Device

    IT WAS REPORTED THAT THE PATIENT'S HIP WAS REVISED DUE TO DISASSOCIATION OF THE 28 +4 LFIT HEAD FROM THE ADM POLY INSERT. PATIENT REPORTED HE HAD SLIPPED AND CAUGHT HIMSELF ON A RAILING WITHOUT FULLY FALLING. THE SURGEON WAS NOT CERTAIN IF THE DISASSOCIATION CAUSED THE SLIP OR VICE VERSA. AFTER A FAILED CLOSED REDUCTION OF THE PATIENT'S HIP, THE PATIENT'S ENTIRE HIP CONSTRUCT WAS REVISED FOR DEVICES OF THE SAME CATALOG NUMBERS, WITH THE EXCEPTION OF A 20 MM SCREW BEING REVISED TO TWO 25 MM SCREWS AS THE SURGEON WAS NOT SURE IF THE SHELL WAS TOO VERTICAL. THE STEM WAS REVISED SOLELY TO GAIN ACCESS TO THE SHELL, THERE ARE NO ALLEGATIONS AGAINST ANY OF THE OTHER REVISED DEVICES. THE DEVICES ARE ALLEGEDLY AVAILABLE FOR RETURN. THE REP REPORTED HE MAY BE ABLE TO GET PRE-REVISION X-RAYS AND POSSIBLY THE PRIMARY OPERATIVE REPORT, AND CONFIRMED THAT NO OTHER INFORMATION WILL BE AVAILABLE.

    Patient problems: Injury

    MAUDE report 9255416 ↗

Other Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented devices

All Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented devices →