NA 2351-0040Recalls & reported problems
Stryker GmbH · Ball Tip Screwdriver · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327361728), received between May 9, 2022 and May 9, 2022 — classified as 1 malfunction.
The most frequently reported specific device problem is “Use of Device Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Use of Device Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 9, 2022Use of Device Problem; Use of Device Problem
AS REPORTED: "THE SURGEON INSERTED A 9MM T2 ALPHA TIBIA NAIL VIA THE SUPRAPATELLAR APPROACH. SURGEON REAMED TO 10.5, AND MEASURED 320. HE CHOSE TO USE A 300 NAIL. THE CANAL WAS NARROW AND THE SURGEON WOULD HAVE USED AN 8MM NAIL IF AVAILABLE. PROXIMAL SCREWS AND THEN DISTAL SCREWS WERE INSERTED. AFTER DISTAL SCREW INSERTION, SURGEON WAS UNABLE TO DETACH NAIL HOLDING BOLT FROM THE IM ROD. THE SURGEON SPENT ~10 MINUTES TRYING TO USE THE BALL TIP SCREW DRIVER TO DISENGAGE THE BOLT. HE WAS UNABLE TO DO SO. VICE GRIPS WERE EVENTUALLY USED TO REMOVE THE SCREW. FORCE AND COUNTER FORCE HAD TO BE USE TO DISENGAGE THE SCREW FROM THE ROD AND REMOVE THE NAIL ADAPTER / NAIL HOLDING BOLT."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14341895 ↗
Other SCREWDRIVER devices
- DELTA XTEND 2307-92-003Depuy (Ireland) · SCREWDRIVER751 reports
- EXPEDIUM 279712400Medos International Sàrl · SCREWDRIVER551 reports
- NA 314.467Synthes GmbH · SCREWDRIVER498 reports
- N/A 5584111Medtronic Sofamor Danek, Inc. · SCREWDRIVER492 reports
- QUICKSET 2274-47-000Depuy (Ireland) · SCREWDRIVER487 reports
- NA 03.130.010Synthes GmbH · SCREWDRIVER1 recall422 reports
- QUICKSET 2274-63-000Depuy (Ireland) · SCREWDRIVER404 reports
- EVOS 71175072Smith & Nephew, Inc. · SCREWDRIVER336 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page