Surpass Elite FDSE40012Recalls & reported problems
Stryker Corporation · Flow Diverter System · Class 3 · Implant
All models of Surpass Elite (17)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613327582697), received between Apr 4, 2025 and Aug 6, 2025 — classified as 2 injuries.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Thrombosis/Thrombus2
- Obstruction/Occlusion1
- Stroke/CVA1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryAug 6, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE SUBJECT DEVICE WAS USED ON (B)(6) 2025. THERE WERE NO ISSUES WITH THE SUBJECT DEVICE DURING THE PROCEDURE AS THE SUBJECT DEVICE WAS PREPPED PER IFU. THE PATIENT WAS ON DUAL ANTI PLATELET, NO THROMBOEMBOLIC EVENTS DURING THE PROCEDURE. PROXIMAL END WAS MALPOSED AND AFTER RUNNING THE INTERMEDIATE CATHETER THROUGH THE DEPLOYED SUBJECT DEVICE, GOOD APPOSITION WAS NOTED AND PROCEDURE WAS SUCCESSFULLY COMPLETED. THE PATIENT DID VERY WELL AND WAS DISCHARGED ON (B)(6) 2025. POST PROCEDURE ON (B)(6) 2025, THE PATIENT DEVELOPED STROKE LIKE SYMPTOMS AND A MECHANICAL THROMBECTOMY WAS PERFORMED AT ANOTHER HOSPITAL WITH A DIFFERENT PHYSICIAN. AN ANGIOGRAM SHOWED THE SUBJECT DEVICE WAS OCCLUDED. PATIENT STOPPED TAKING THEIR DUAL ANTIPLATELET MEDICATIONS SINCE BEING DISCHARGED ON (B)(6) 2025 RESULTING IN THE FORMATION OF THROMBUS THROUGHOUT THE ENTIRE SUBJECT DEVICE AND THE THROMBECTOMY. BASED ON THE PHYSICIAN¿S OPINION STATED THAT THE REPORTED EVENT DUE TO THE LACK OF DUAL ANTIPLATELET THERAPY CAUSING CLOT FORMATION WITHIN THE SUBJECT DEVICE. THE PATIENT IS ALIVE WITH DEFICITS AND IS STILL IN HOSPITAL BEING MEDICALLY MANAGED FOR HYDROCEPHALUS.
Patient problems: Stroke/CVA; Thrombosis/Thrombus
MAUDE report 22728278 ↗InjuryApr 4, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE SUBJECT STENT WAS SUCCESSFULLY DEPLOYED INTO THE PATIENT¿S LEFT INTERNAL CAROTID ARTERY (ICA) WITH MINIMAL MANIPULATION AND NO POST-DEPLOYMENT PROCESSING NEEDED. HOWEVER, A FEW MINUTES AFTER DEPLOYMENT, A CLOT DEVELOPED AT THE DISTAL END OF THE STENT, OBSTRUCTING FLOW INTO THE A1 SEGMENT OF THE ANTERIOR CEREBRAL ARTERY. THE PHYSICIAN CONFIRMED THAT THE PATIENT WAS RESPONSIVE TO DUAL ANTIPLATELET THERAPY (DAPT) WITH BRILINTA AND HAD NO KNOWN METAL ALLERGIES. TO RESOLVE THE OCCLUSION, THE PATIENT WAS ADMINISTERED A BOLUS DOSE AND PLACED ON A CONTINUOUS INFUSION OF EITHER AGGRASTAT OR INTEGRILIN, WHICH SUCCESSFULLY DISSOLVED THE CLOT AND RESTORED BLOOD FLOW WITHIN 30 MINUTES. THERE WAS A 35 MINUTE PROCEDURAL DELAY. THE PATIENT¿S CONDITION IMPROVED AND WAS DISCHARGED FROM THE HOSPITAL THREE DAYS AFTER THE PROCEDURE, WITH NO SIGNS OF NEUROLOGICAL DEFICITS. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: Obstruction/Occlusion; Thrombosis/Thrombus
MAUDE report 21778842 ↗
Other Intracranial aneurysm flow diverter devices
- Pipeline TM Flex Embolization Device with Shield Technology TM PED2-300-12Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter2 recalls1 report
- PIPELINE PED-500-20Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall31 reports
- PIPELINE PED-500-35Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall1 death29 reports
- PIPELINE PED-500-16Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall2 deaths27 reports
- PIPELINE PED-500-25Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall1 death23 reports
- PIPELINE PED-500-30Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall21 reports
- PIPELINE PED-450-25Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall20 reports
- PIPELINE PED-475-30Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall1 death19 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page