Stryker Corporation · Flow Diverter System · Class 3 · Implant

All models of Surpass Elite (17)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613327582697), received between Apr 4, 2025 and Aug 6, 2025 — classified as 2 injuries.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2

Patient problems

  • Thrombosis/Thrombus2
  • Obstruction/Occlusion1
  • Stroke/CVA1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 6, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE SUBJECT DEVICE WAS USED ON (B)(6) 2025. THERE WERE NO ISSUES WITH THE SUBJECT DEVICE DURING THE PROCEDURE AS THE SUBJECT DEVICE WAS PREPPED PER IFU. THE PATIENT WAS ON DUAL ANTI PLATELET, NO THROMBOEMBOLIC EVENTS DURING THE PROCEDURE. PROXIMAL END WAS MALPOSED AND AFTER RUNNING THE INTERMEDIATE CATHETER THROUGH THE DEPLOYED SUBJECT DEVICE, GOOD APPOSITION WAS NOTED AND PROCEDURE WAS SUCCESSFULLY COMPLETED. THE PATIENT DID VERY WELL AND WAS DISCHARGED ON (B)(6) 2025. POST PROCEDURE ON (B)(6) 2025, THE PATIENT DEVELOPED STROKE LIKE SYMPTOMS AND A MECHANICAL THROMBECTOMY WAS PERFORMED AT ANOTHER HOSPITAL WITH A DIFFERENT PHYSICIAN. AN ANGIOGRAM SHOWED THE SUBJECT DEVICE WAS OCCLUDED. PATIENT STOPPED TAKING THEIR DUAL ANTIPLATELET MEDICATIONS SINCE BEING DISCHARGED ON (B)(6) 2025 RESULTING IN THE FORMATION OF THROMBUS THROUGHOUT THE ENTIRE SUBJECT DEVICE AND THE THROMBECTOMY. BASED ON THE PHYSICIAN¿S OPINION STATED THAT THE REPORTED EVENT DUE TO THE LACK OF DUAL ANTIPLATELET THERAPY CAUSING CLOT FORMATION WITHIN THE SUBJECT DEVICE. THE PATIENT IS ALIVE WITH DEFICITS AND IS STILL IN HOSPITAL BEING MEDICALLY MANAGED FOR HYDROCEPHALUS.

    Patient problems: Stroke/CVA; Thrombosis/Thrombus

    MAUDE report 22728278 ↗
  • InjuryApr 4, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE SUBJECT STENT WAS SUCCESSFULLY DEPLOYED INTO THE PATIENT¿S LEFT INTERNAL CAROTID ARTERY (ICA) WITH MINIMAL MANIPULATION AND NO POST-DEPLOYMENT PROCESSING NEEDED. HOWEVER, A FEW MINUTES AFTER DEPLOYMENT, A CLOT DEVELOPED AT THE DISTAL END OF THE STENT, OBSTRUCTING FLOW INTO THE A1 SEGMENT OF THE ANTERIOR CEREBRAL ARTERY. THE PHYSICIAN CONFIRMED THAT THE PATIENT WAS RESPONSIVE TO DUAL ANTIPLATELET THERAPY (DAPT) WITH BRILINTA AND HAD NO KNOWN METAL ALLERGIES. TO RESOLVE THE OCCLUSION, THE PATIENT WAS ADMINISTERED A BOLUS DOSE AND PLACED ON A CONTINUOUS INFUSION OF EITHER AGGRASTAT OR INTEGRILIN, WHICH SUCCESSFULLY DISSOLVED THE CLOT AND RESTORED BLOOD FLOW WITHIN 30 MINUTES. THERE WAS A 35 MINUTE PROCEDURAL DELAY. THE PATIENT¿S CONDITION IMPROVED AND WAS DISCHARGED FROM THE HOSPITAL THREE DAYS AFTER THE PROCEDURE, WITH NO SIGNS OF NEUROLOGICAL DEFICITS. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: Obstruction/Occlusion; Thrombosis/Thrombus

    MAUDE report 21778842 ↗