32" 4K OLED Surgical Display 0240031300Recalls & reported problems

Stryker Corporation · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
9
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 07613327592146), received between Apr 17, 2023 and Sep 11, 2026 — classified as 9 malfunctions.

The most frequently reported specific device problem is “No Display/Image” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 3 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • No Display/Image6
  • Output Problem4
  • Connection Problem1
  • Device Fell1
  • Electrical Power Problem1
  • Temperature Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions9

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 11, 2026No Display/Image

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50744581 ↗
  • MalfunctionDec 5, 2025Device Fell; Device Fell

    IT WAS REPORTED THAT OLED MONITOR CAME OFF ITS BACK PLATE AND FELL IN AN OR DURING SURGERY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23734896 ↗
  • MalfunctionNov 25, 2025No Display/Image; Connection Problem; No Display/Image; Connection Problem

    IT WAS REPORTED THAT THE DEVICE FAILED AND SHUT OFF IN THE MIDDLE OF A CASE CAUSING FULL LOSS OF IMAGE ON PRIMARY MONITOR. DURATION OF LOSS OF IMAGE WAS THAT IT NEVER CAME BACK ON. IT WAS FOR THE REMAINING PORTION OF THE CASE WHICH WAS APPROXIMATELY 60-90 MINUTE RANGE. PROCEDURE COMPLETED USING THE SECONDARY MONITOR. THERE WAS NO SURGICAL DELAY, IT WAS MORE ABOUT "PIVOTING" TO THE SECONDARY MONITOR TO COMPLETE THE CASE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23651038 ↗
  • MalfunctionSep 30, 2025No Display/Image; No Display/Image

    THE DEVICE IS THE PRIMARY MONITOR. THE OLED SCREEN TURNED WHITE AND WOULD NOT ROUTE TO A DIFFERENT SCREEN. THERE WAS AN IMAGE LOSS AND IT REMAINED LOST. THE IMAGE NEVER RETURNED AND THE CURRENT MONITOR IS NO LONGER USABLE. TO COMPLETE THE PROCEDURE, THERE WAS ANOTHER OLED HANGING IN THE ROOM, AND THE PROCEDURE WAS FINISHED WITH THAT MONITOR. THIS CAUSED A DELAY OF ABOUT 10 MINUTES

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23186996 ↗
  • MalfunctionAug 13, 2025No Display/Image; Output Problem; No Display/Image; Output Problem

    IT WAS REPORTED THAT DURING THE SURGERY, THE TOWER WAS FUNCTIONING NORMALLY WHEN SUDDENLY THE MONITOR TURNED OFF AND DID NOT DISPLAY AN IMAGE AT ANY TIME AFTERWARD. AFTER QUICKLY CHECKING POSSIBLE SOLUTIONS, THE MONITOR STILL DID NOT SHOW AN IMAGE, WHICH LED TO AN IMMEDIATE REPLACEMENT OF THE TOWER WITH ANOTHER UNIT PROVIDED BY THE CLIENT. NO ADVERSE EVENT OCCURRED, ALTHOUGH THE PROCEDURE TIME WAS EXTENDED DUE TO THE EQUIPMENT CHANGE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22798159 ↗
  • MalfunctionDec 22, 2023No Display/Image; Output Problem; No Display/Image; Output Problem

    IT WAS REPORTED THAT THERE WAS LOSS OF IMAGE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18387624 ↗
  • MalfunctionDec 21, 2023No Display/Image; Output Problem; No Display/Image; Output Problem

    IT WAS REPORTED THAT THERE WAS LOSS OF IMAGE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18376401 ↗
  • MalfunctionDec 13, 2023Electrical Power Problem; Temperature Problem; Electrical Power Problem; Temperature Problem

    IT WAS REPORTED THAT THERE WAS A THERMAL EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18318715 ↗
  • MalfunctionApr 17, 2023Output Problem; Output Problem

    IT WAS REPORTED THAT THERE WAS LOSS OF IMAGE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16753845 ↗

Other CAMERA, TELEVISION, SURGICAL, WITHOUT AUDIO devices

All CAMERA, TELEVISION, SURGICAL, WITHOUT AUDIO devices →