Versafitcup CC TRIO Acetabular System 01.26.3244HCTRecalls & reported problems

Medacta International SA · Flat PE HC liner Ø 32 / E · Class 2 · Implant

All models of Versafitcup CC TRIO Acetabular System (32)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
19
Deaths reported
0
Injuries reported
16
Recalls naming it
0

Summary

The FDA's MAUDE database contains 19 adverse event reports that list this exact device (DI 07630030807572), received between Sep 6, 2017 and May 7, 2025 — classified as 16 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem5
  • Appropriate Device Problem Term/Code Not Available5
  • Device Dislodged or Dislocated4
  • Degraded1
  • Device Issue1
  • Difficult to Insert1
  • Naturally Worn1
  • No Apparent Adverse Event1

Patient problems

  • Unspecified Infection6
  • Joint Dislocation5
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available2
  • No Clinical Signs, Symptoms or Conditions2
  • Cyst(s)1
  • Joint Disorder1
  • No Code Available1
  • No Information1

Recent adverse event reports

The 19 most recent of 19 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 7, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    DURING SURGERY THE SURGEON COULD NOT COUPLE THE LINER WITH THE CUP. AFTER MULTIPLE ATTEMPTS A NEW IMPLANT WAS OPENED WHICH CLIPPED SUCCESSFULLY. 30 MINUTES OF DELAY WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21975575 ↗
  • InjuryApr 30, 2025No Apparent Adverse Event; No Apparent Adverse Event

    REVISION SURGERY PERFORMED DUE TO PAIN AT ABOUT 10 YEARS FROM THE PRIMARY SURGERY. LINER AND BALL HEAD REVISED SUCCESSFULLY.

    Patient problems: Pain

    MAUDE report 21932981 ↗
  • InjuryDec 12, 2024Degraded; Degraded

    REVISION SURGERY PERFORMED AT ABOUT 14 YEARS 5 MONTHS AFTER THE PRIMARY FOR UNKNOWN REASON. THE SURGEON REVISED THE LINER AND HEAD. SOME WEAR OF THE PE COMPONENT IS VISIBLE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 20911253 ↗
  • InjuryJul 11, 2024Naturally Worn; Naturally Worn

    AT ABOUT 10 YEARS AND 1 MONTH AFTER PRIMARY, THE PATIENT HAS BEEN REVISED BECAUSE OF CYST RESORPTION PROBABLY CAUSED BY PE LINER WEAR. THE LINER HAS BEEN SUCCESSFULLY REVISED.

    Patient problems: Cyst(s)

    MAUDE report 19719230 ↗
  • InjuryJul 6, 2023Device Dislodged or Dislocated; Device Dislodged or Dislocated

    REVISION SURGERY AT ABOUT 8 YEARS AND 3 MONTHS POST PRIMARY, REVISION SURGERY FOR HIP LUXATION. LINER AND HEAD REVISED SUCCESSFULLY.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 17265750 ↗
  • MalfunctionJun 15, 2022Difficult to Insert

    IT WAS NOT POSSIBLE TO INSERT THE VERSAFITCUP PE HC LINER E 32MM IN THE VERSAFITCUP 52MM. THE SURGEON TRIED 2 LINERS AND IT WAS EITHER NOT POSSIBLE. AFTERWARD, HE IMPLANTED THE 54MM VERSAFIT AND WITH THIS CUP, IT WAS POSSIBLE TO INSERT THE SAME LINER. AT LEAST 30 MINUTES OF DELAY OCCURRED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14694831 ↗
  • InjuryFeb 18, 2022Adverse Event Without Identified Device or Use Problem

    LUXATED HIP PROSTHESIS. REVISION SURGERY PERFORMED 5 YEARS AND 11 MONTHS AFTER THE PRIMARY SURGERY. HEAD AND LINER REVISED.

    Patient problems: Joint Dislocation

    MAUDE report 13558377 ↗
  • InjuryFeb 7, 2022Appropriate Device Problem Term/Code Not Available

    INFECTION AFTER WOUND HEALING DISORDER. HEAD AND LINER REVISED 2 MONTHS AFTER THE PRIMARY SURGERY.

    Patient problems: Unspecified Infection

    MAUDE report 13469560 ↗
  • InjurySep 10, 2021Device Dislodged or Dislocated

    REVISION SURGERY PLANNED FOR (B)(6) 2021 DUE TO DISLOCATION OF THE HEAD FROM THE LINER. THE PRIMARY DATE IS UNKNOWN. NO MORE INFORMATION IS AVAILABLE AT THIS MOMENT.

    Patient problems: Joint Dislocation

    MAUDE report 12452400 ↗
  • InjuryMar 11, 2021Device Dislodged or Dislocated

    REVISION SURGERY DUE TO DISLOCATION OF THE HEAD FROM THE LINER 1 MONTH AFTER THE PRIMARY. THE SURGEON REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Dislocation

    MAUDE report 11463080 ↗
  • InjurySep 2, 2020Adverse Event Without Identified Device or Use Problem

    THE PATIENT HAS A LOW GRADE INFECTION WITH STAPHYLOCOCCUS EPIDERMIDIS. 7 MONTHS AFTER PRIMARY THE SURGEON EXPLANTED SUCCESSFULLY ALL THE DEVICES.

    Patient problems: Unspecified Infection

    MAUDE report 10482178 ↗
  • InjuryApr 29, 2020Device Dislodged or Dislocated

    THE PATIENT CAME IN REPORTING PAIN DUE TO A DISLOCATION OF THE HEAD FROM THE LINER 2 YEARS AND 5 MONTHS AFTER THE PRIMARY. THE CAUSE OF THE DISLOCATION IS UNKNOWN. THE SURGEON REVISED THE CUP, LINER, AND HEAD AND THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Dislocation

    MAUDE report 10008491 ↗
  • InjuryApr 3, 2020Appropriate Device Problem Term/Code Not Available

    REVISION SURGERY PERFORMED ON THE (B)(6) 2020 DUE TO INFECTION, THE SURGEON CHANGED THE INLAY AND HEAD. HEAD WAS NOT A MEDACTA PRODUCT. PRIMARY DETAILS ARE UNKNOWN.

    Patient problems: Unspecified Infection

    MAUDE report 9919753 ↗
  • InjuryFeb 14, 2020Appropriate Device Problem Term/Code Not Available

    REVISION SURGERY PERFORMED DUE TO INFECTION. ONLY THE INLAY HAS BEEN CHANGED.

    Patient problems: Unspecified Infection

    MAUDE report 9710854 ↗
  • InjuryOct 30, 2019Appropriate Device Problem Term/Code Not Available

    DURING A FOLLOW UP, THE SURGEON DISCOVERED THAT THE PATIENT HAD SUBCUTANEOUS STORAGE AREA WITH DEEDING OF THE WOUND ON THE DISTAL PART AND IMBIBITION OF TISSUES AND REDDENING. FEW DAYS LATER THE PATIENT WAS REVISED, LINER AND HEAD WERE REMOVED, PROBABLY DUE TO INFECTION, PATHOGEN IS STAPHYLOCOCCUS AUREUS. THE REVISION HAS BEEN PERFORMED 20 DAYS AFTER PRIMARY SURGERY.

    Patient problems: Unspecified Infection

    MAUDE report 9255107 ↗
  • InjuryJan 10, 2019Adverse Event Without Identified Device or Use Problem

    THE PATIENT WAS REVISED TWO TIMES ((B)(6) 2018) DUE TO HIP DISLOCATION, 4 AND 5 MONTHS AFTER PRIMARY.

    Patient problems: Joint Dislocation; No Code Available

    MAUDE report 8235402 ↗
  • InjuryNov 13, 2018Appropriate Device Problem Term/Code Not Available

    PATIENT RETURNED TO HOSPITAL WITH POSSIBLE INFECTION 9 MONTHS AFTER PRIMARY SURGERY. HIP WASHOUT WAS PERFORMED AND NO INFECTION DETECTED. BEARING SURFACES REVISED TO PROVIDE NEW ARTICULATING SURFACES.

    Patient problems: Joint Disorder

    MAUDE report 8064116 ↗
  • MalfunctionDec 28, 2017Device Issue; Device Issue

    THE INLAY DID NOT FIT INTO THE CUP, THE SIZE WAS CORRECT. AFTER A FEW TIMES TRYING, A NEW PE LINER E WAS OPENED AND IT WORKED.

    Patient problems: No Information

    MAUDE report 7150720 ↗
  • InjurySep 6, 2017Adverse Event Without Identified Device or Use Problem

    THE PATIENT HAD AN INFECTION AND THE SURGEON DECIDED TO TAKE OUT THE PLATE, CHANGE THE MOBILE PARTS OF THE PROSTHESIS (LINER AND HEAD) AND REPLACE ANOTHER PLATE. THE SURGEON REVISED THE INSERT LINER AND REPLACED THE CERAMIC HEAD WITH A CRCO BALL HEAD. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Unspecified Infection

    MAUDE report 6844649 ↗

Other Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented devices

All Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented devices →