Mectacer Biolox Delta Femoral Ball Head 01.29.210Recalls & reported problems

Medacta International SA · Femoral Head Ø 36 Size L · Class 2 · Implant

All models of Mectacer Biolox Delta Femoral Ball Head (15)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Medacta Biolox Delta ceramic femoral head is the ball-and-socket component used in hip replacement surgery. The reports mostly describe infection around the implant, along with the ball coming out of its socket (dislocation), pain, and one case of a leg length mismatch, several needing revision surgery to clean out or swap parts. There are 48 reports, all describing injuries, and no deaths. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
48
Deaths reported
0
Injuries reported
48
Recalls naming it
0

Summary

The FDA's MAUDE database contains 48 adverse event reports that list this exact device (DI 07630030809217), received between Apr 5, 2018 and May 22, 2026 — classified as 48 injuries.

The most frequently reported specific device problem is “Device Appears to Trigger Rejection” (22 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 2 reportsNov 2024: 3 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 2 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 2 reportsJun 2025: 0 reportsJul 2025: 2 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 2 reportsApr 2026: 1 reportsMay 2026: 2 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Appears to Trigger Rejection22
  • Device Dislodged or Dislocated11
  • Adverse Event Without Identified Device or Use Problem5
  • Appropriate Device Problem Term/Code Not Available5
  • Break1
  • Difficult to Remove1
  • Loosening of Implant Not Related to Bone-Ingrowth1
  • Microbial Contamination of Device1

Patient problems

  • Unspecified Infection16
  • Medical device site infection13
  • Joint Dislocation7
  • Pain4
  • Implant Pain3
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Bacterial Infection1
  • Hematoma1

Recent adverse event reports

The 25 most recent of 48 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 22, 2026Device Appears to Trigger Rejection

    REVISION SURGERY DUE TO INFECTION AFTER ABOUT 1 MONTH AND A HALF FROM PRIMARY. THE SURGEON PERFORMED A WASHOUT, THEN REVISED THE 36MM BIOLOX L HEAD TO A 36MM BIOLOX OPTION HEAD WITH SLEEVE, AND REVISED THE FLAT PE HC LINER D 36/E TO A SAME SIZE LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 25253488 ↗
  • InjuryMay 5, 2026Device Appears to Trigger Rejection

    REVISION SURGERY DUE TO INFECTION AFTER 6 MONTHS FROM PRIMARY SURGERY. THE SURGEON UPSIZED THE MPACT 3D METAL SHELL, MPACT LINER AND HEAD. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 25077220 ↗
  • InjuryApr 23, 2026Device Appears to Trigger Rejection

    REVISION SURGERY DUE TO INFECTION ABOUT 8 YEARS AFTER PRIMARY SURGERY AND THE CAUSE IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE HEAD, THE ACETABULAR SHELL, LINER AND THE STEM. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 24964781 ↗
  • InjuryMar 26, 2026Device Appears to Trigger Rejection

    AT ABOUT 3 YEARS AND 3 MONTHS FROM THE PRIMARY, THE PATIENT CAME IN DUE TO SIGNS OF INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE 36 MM BIOLOX HEAD TO A SAME SIZE BIOLOX HEAD AND REVISED THE D 36 HOODED LINER TO A FLAT PE HC LINER D 36 LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 24700711 ↗
  • InjuryMar 10, 2026Device Appears to Trigger Rejection

    REVISION SURGERY DUE TO INFECTION 20 DAYS AFTER THE PRIMARY SURGERY. THE SURGEON PERFORMED A WASHOUT AND REVISED THE HEAD AND LINER TO A SAME SIZE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 24558229 ↗
  • InjurySep 17, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    THE PATIENT UNDERWENT PRIMARY SURGERY ON (B)(6) 2025. ON (B)(6) 2025, THE PATIENT PRESENTED WITH DRAINAGE AT THE INCISION SITE AND A HEMATOMA. THE SURGEON PERFORMED AN I&D AND EXCHANGED THE HEAD AND POLYETHYLENE. RECENTLY, THE PATIENT PRESENTED AGAIN DUE TO INFECTION OF UNKNOWN PATHOGEN. THE SURGEON PERFORMED A WASHOUT AND EXCHANGED THE HEAD. THE SURGERY WAS SUCCESSFULLY COMPLETED.

    Patient problems: Medical device site infection

    MAUDE report 23070935 ↗
  • InjuryJul 31, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT CAME IN REPORTING INSTABILITY DUE TO A LEG LENGTH DISCREPANCY, AND THE CAUSE IS UNKNOWN. THE SURGEON DOWNSIZED THE HEAD TO GIVE THE PATIENT MORE STABILITY. THE SURGERY WAS COMPLETED SUCCESSFULLY. HEAD SIZE WAS DECREASED BECAUSE LEG WAS TOO LONG. X-RAYS NOT AVAILABLE.

    Patient problems: Unequal Limb Length

    MAUDE report 22673490 ↗
  • InjuryJul 8, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THE PATIENT CAME HAD PAIN DUE TO A DISLOCATION OF THE HEAD FROM THE LINER. AT ABOUT 2 MONTHS FROM PRIMARY THE SURGEON REVISED THE HEAD AND LINER AND THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Dislocation

    MAUDE report 22436992 ↗
  • InjuryMay 23, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    AT ABOUT THREE WEEKS FROM PRIMARY, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 22076616 ↗
  • InjuryMay 16, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    AT 1 MONTH FROM PRIMARY, THE PATIENT CAME IN REPORTING PAIN DUE TO DEVELOPING A HEMATOMA. THE SURGEON PERFORMED ADRENAGE AND REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Hematoma

    MAUDE report 22033729 ↗
  • InjuryMar 27, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    THE PATIENT HAD A PRIMARY HIP SURGERY ON (B)(6) 2024. ON (B)(6) 2025, THE PATIENT CAME IN DUE TO SIGNS OF INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY. PRESENTLY, ON (B)(6) 2025, THE PATIENT CAME IN DUE TO SIGNS OF INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON REMOVED ALL MEDACTA HARDWARE AND IMPLANTED AN ANTIBIOTIC SPACER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 21708477 ↗
  • InjuryFeb 19, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    THE PATIENT HAD A HIP INFECTION AND THE PATHOGEN IS UNKNOWN. AT ABOUT 1 MONTH POST PRIMARY THE SURGEON PERFORMED A WASHOUT AND REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 21411268 ↗
  • InjuryFeb 11, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    THE PATIENT HAD A HIP INFECTION AND THE PATHOGEN IS UNKNOWN. AT ABOUT 5 YEARS AND 5 MONTHS POST PRIMARY THE SURGEON PERFORMED A WASHOUT AND REVISED THE CUP, HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 21353077 ↗
  • InjuryJan 14, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    AT ABOUT 1 YEAR 10 MONTHS AFTER THE PRIMARY, THE PATIENT CAME IN DUE TO SIGNS OF INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 21146987 ↗
  • InjuryNov 18, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    AT ABOUT 4 MONTHS AFTER THE PRIMARY, THE PATIENT CAME IN REPORTING PAIN DUE TO A DISLOCATION OF THE HEAD FROM THE LINER AND THE CAUSE OF THE DISLOCATION IS UNKNOWN. THE SURGEON REVISED THE CUP, HEAD AND LINER AND THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Dislocation

    MAUDE report 20705351 ↗
  • InjuryNov 13, 2024Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    AT ABOUT 1 MONTH AFTER PRIMARY, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE HEAD, CUP AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Unspecified Infection

    MAUDE report 20674180 ↗
  • InjuryNov 7, 2024Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    REVISION DUE TO SIGNS OF INFECTION AT ABOUT 2 WEEKS FROM PRIMARY AND THE PATHOGEN IS UNKNOWN. THE SURGEON REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 20628625 ↗
  • InjuryOct 29, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    AT ABOUT 10 MONTHS AFTER PRIMARY, THE PATENT CAME IN REPORTING PAIN DUE TO A JOINT LUXATION AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Implant Pain

    MAUDE report 20554923 ↗
  • InjuryOct 18, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THE PATIENT HAD PAIN DUE TO A LUXATION OF THE HEAD FROM THE LINER. AT ABOUT 3 MONTHS POST PRIMARY THE SURGEON REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Implant Pain

    MAUDE report 20485051 ↗
  • InjurySep 17, 2024Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. ABOUT 1 MONTH AFTER THE PRIMARY SURGERY, THE SURGEON PERFORMED A WASHOUT AND REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Unspecified Infection

    MAUDE report 20235663 ↗
  • InjuryJun 19, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    AT ABOUT 1 MONTH AFTER THE PRIMARY, THE PATIENT CAME IN REPORTING PAIN DUE TO A DISLOCATION OF THE HEAD FROM THE LINER AND THE CAUSE OF THE DISLOCATION IS UNKNOWN. THE SURGEON REVISED THE HEAD AND THE SURGERY WAS COMPLETED SUCCESSFULLY. CUP AND LINER WAS COMPETITOR'S.

    Patient problems: Implant Pain

    MAUDE report 19566132 ↗
  • InjuryApr 9, 2024Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    ABOUT 3 MONTHS AFTER THE PRIMARY SURGERY, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Unspecified Infection

    MAUDE report 19070203 ↗
  • InjuryJan 17, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IMMEDIATELY AFTER THE PRIMARY HIP SURGERY, THE PATIENT SUSTAINED A DISLOCATION OF THE HEAD FROM THE LINER. THE SURGEON REVISED THE STEM, HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Pain

    MAUDE report 18525667 ↗
  • InjurySep 22, 2023Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    AT ABOUT 3 YEARS AND 8 MONTHS FROM THE PRIMARY, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 17798546 ↗
  • InjuryJul 26, 2023Device Dislodged or Dislocated; Device Dislodged or Dislocated

    REVISION FOR JOINT LUXATION AT ABOUT 1 YEAR AND 1 MONTH POST PRIMARY. MECTACER HEAD AND MPACT FLAT LINER CHANGED SUCCESSFULLY.

    Patient problems: Pain

    MAUDE report 17396945 ↗

Other Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented devices

All Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented devices →