Mpact Acetabular System 01.32.3644HCATRecalls & reported problems

Medacta International SA · Hooded PE HC Liner Ø 36 / E · Class 2 · Implant

All models of Mpact Acetabular System (68)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
10
Deaths reported
0
Injuries reported
10
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 07630030812101), received between Jan 12, 2018 and Nov 28, 2025 — classified as 10 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Appropriate Device Problem Term/Code Not Available4
  • Adverse Event Without Identified Device or Use Problem2
  • Device Dislodged or Dislocated2
  • Device Appears to Trigger Rejection1
  • Unstable1

Patient problems

  • Unspecified Infection3
  • Joint Dislocation2
  • Medical device site infection2
  • Failure of Implant1
  • Implant Pain1
  • Joint Disorder1
  • Joint Laxity1
  • Pain1

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ON (B)(6) 2015, THE PATIENT HAD PRIMARY HIP SURGERY. ON (B)(6) 2025, THE PATIENT CAME IN REPORTING PAIN DUE TO A LOOSE STEM AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE MEDACTA STEM AND HEAD WITH COMPETIITOR COMPONENTS AND REVISED THE MEDACTA LINER WITH A MEDACTA LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY (B)(4). ON (B)(6) 2025, THE PATIENT CAME IN DUE TO PAIN AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE LINER TO PROVIDE MORE OFFSET. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Implant Pain

    MAUDE report 23669512 ↗
  • InjuryApr 24, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    REVISION SURGERY DUE TO JOINT LUXATION, FEW DAYS AFTER THE PRIMARY SURGERY AND CLOSE REDUCTION. THE HIP WAS UNSTABLE ALSO DURING REVISION SURGERY AND LED TO SURGEON DECISION TO REVISE ALL COMPONENTS.

    Patient problems: Joint Dislocation; Joint Laxity

    MAUDE report 19173866 ↗
  • InjuryNov 15, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AT ABOUT 1 MONTH AFTER PRIMARY, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 18139705 ↗
  • InjuryDec 19, 2022Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    AT ABOUT 1 MONTH AND 2 WEEKS AFTER THE PRIMARY SURGERY, THE PATIENT CAME IN DUE TO SIGNS OF INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED SUCCESSFULLY THE HEAD AND LINER.

    Patient problems: Medical device site infection

    MAUDE report 16004172 ↗
  • InjuryApr 20, 2022Appropriate Device Problem Term/Code Not Available

    AT 3 YEARS 5 MONTHS AFTER THE PRIMARY, THE PATIENT CAME IN REPORTING PAIN PATIENT DUE TO PSOAS MUSCLE IRRITATION AND THE CAUSE OF THIS IRRITATION IS UNKNOWN. THE SURGEON REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Pain

    MAUDE report 14157897 ↗
  • InjuryDec 10, 2021Appropriate Device Problem Term/Code Not Available

    THE PATIENT CAME IN 1 MONTH AFTER THE PRIMARY SURGERY DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE HEAD AND LINER AND THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Unspecified Infection

    MAUDE report 12974380 ↗
  • InjuryApr 26, 2021Appropriate Device Problem Term/Code Not Available

    THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE POLY 2 YEARS AND 2 MONTHS AFTER PRIMARY. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Unspecified Infection

    MAUDE report 11723874 ↗
  • InjuryDec 13, 2019Appropriate Device Problem Term/Code Not Available

    THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Unspecified Infection

    MAUDE report 9464962 ↗
  • InjuryJan 9, 2019Device Dislodged or Dislocated

    THE PATIENT HAD A PRIMARY HIP SURGERY ON (B)(6) 2017 AND SUBSEQUENTLY DISLOCATED. ON (B)(6) 2018, THE LINER WAS REVISED WITH A MEDACTA LINER AND THE HEAD WAS REVISED WITH ANOTHER COMPANY'S HEAD . PRESENTLY, THE PATIENT CAME IN DUE TO A DISLOCATION OF THE HEAD FROM THE LINER. THE SURGEON REVISED THE MEDACTA CUP AND LINER WITH ANOTHER COMPANY'S PRODUCT AND REVISED THE COMPETITOR'S HEAD WITH ANOTHER COMPANY'S HEAD. THE SURGERY WAS COMPLETED SUCCESSFULLY. A POSTERIOR APPROACH WAS USED IN PRIMARY SURGERY.

    Patient problems: Failure of Implant; Joint Dislocation

    MAUDE report 8230874 ↗
  • InjuryJan 12, 2018Unstable

    THE PATIENT COMPLAINED HIP INSTABILITY. THE SURGEON REVISED THE PATIENT SWAPPING SUCCESSFULLY THE LINER.

    Patient problems: Joint Disorder

    MAUDE report 7185481 ↗

Other Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented devices

All Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented devices →