Mpact 3D Metal 01.38.052DHRecalls & reported problems
Medacta International SA · Acetabular shell Ø52 Two-hole · Class 2 · Implant
All models of Mpact 3D Metal (8)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 0
- Injuries reported
- 6
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 07630030812590), received between Feb 22, 2019 and Apr 17, 2026 — classified as 6 injuries, 1 malfunction.
The most frequently reported specific device problem is “Positioning Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Positioning Problem2
- Appropriate Device Problem Term/Code Not Available1
- Failure to Osseointegrate1
- Osseointegration Problem1
- Separation Problem1
Patient problems
- Pain2
- Aseptic loosening1
- Implant Pain1
- Inadequate Osseointegration1
- Inflammation1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
InjuryApr 17, 2026Osseointegration Problem; Positioning Problem
THE PATIENT HAD PAIN AS A RESULT OF A LOOSE CUP. AT ABOUT 2 YEARS AND 8 MONTHS POST PRIMARY THE SURGEON REVISED THE MEDACTA CUP AND LINER TO A COMPETITOR CUP AND LINER, AND REVISED THE MEDACTA COCR Ø36MM HEAD TO A MEDACTA 28MM BIOLOX OPTION HEAD WITH SLEEVE. THE SURGERY WAS COMPLETED SUCCESSFULLY. IT WAS REPORTED BY THE AGENT THAT AN FIBROUS BUILDUP (CAUSED ORIGINIALLY BY A SUBOPTIMAL POSITIONING OF THE SHELL) IN THE JOINT COULD HAVE CONTRIBUTED TO THE IMPLANT LOOSENING, BUT THERE IS NO CONFIRMATION THAT THIS COULD BE THE REASON FOR REVISION AND PATIENT PAIN AND SUCCESSIVE LOOSENING.
Patient problems: Aseptic loosening
MAUDE report 24911611 ↗InjuryJun 27, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT HAD PAIN DUE TO A MISPOSITIONED CUP AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE MEDACTA CUP AND LINER TO COMPETITOR COMPONENTS AND THE MEDACTA HEAD TO A MEDACTA HEAD. THE SURGERY WAS COMPLETED SUCCESSFULLY. THE CAUSE OF THE MALPOSITIONED CUP IS UNKNOWN. THE HEAD WAS REVISED TO ADD MORE STABILITY.
Patient problems: Pain
MAUDE report 22343744 ↗InjuryMar 1, 2024Positioning Problem; Positioning Problem
REVISION SURGERY DUE TO PAIN AND CUP POSITIONED TOO VERTICAL, AT ABOUT 1 YEAR 5 MONTHS AFTER PRIMARY. CUP, LINER AND HEAD REVISED SUCCESSFULLY.
Patient problems: Implant Pain
MAUDE report 18817503 ↗InjuryJul 5, 2023Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
AT ABOUT 4 YEARS AFTER THE PRIMARY, THE PATIENT CAME IN REPORTING PAIN DUE TO ILIOPSOAS TENDONITIS AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE MEDACTA CUP AND LINER TO COMPETITOR COMPONENTS AND REVISED THE MEDACTA HEAD TO A MEDACTA HEAD. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Inflammation
MAUDE report 17256405 ↗InjuryFeb 24, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT CAME IN REPORTING GROIN PAIN AND THE CAUSE IS UNKNOWN. THE SURGEON BELIEVED THAT A LOOSE ACETABULAR IMPLANT WAS PRESENT. DURING THE REVISION SURGERY (AT ABOUT 2 YEARS AND 5 MONTHS FROM PRIMARY), HOWEVER, THE SURGEON NOTED THAT THE JOINT WAS STABLE AND THE CUP WAS DIFFICULT TO REMOVE. THE SURGEON DID OBSERVE THAT THERE WAS CIRCUMFERENTIAL BONY INGROWTH AS HE REMOVED THE CUP. THE SURGEON REVISED THE MEDACTA CUP, LINER, AND SCREWS WITH COMPETITOR COMPONENTS AND REVISED THE MEDACTA HEAD WITH A MEDACTA HEAD. THE SURGERY WAS COMPLETED SUCCESSFULLY. NO COMMENT FROM THE SURGEON ABOUT A POSSIBLE REASON OF PATIENT'S PAIN. THE SURGEON HAS NO REASON/THEORY ABOUT WHAT THE CAUSE OF THE PAIN WAS.
Patient problems: Pain
MAUDE report 16435539 ↗InjuryJul 26, 2021Failure to Osseointegrate
THE PATIENT CAME IN REPORTING PAIN DUE TO THE CUP NOT GROWING IN. THE CAUSE OF THE CUP NOT GROWING IN IS UNKNOWN. 3 MONTHS AFTER PRIMARY THE SURGEON REVISED THE CUP AND LINER AND THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Inadequate Osseointegration
MAUDE report 12224557 ↗MalfunctionFeb 22, 2019Separation Problem
DURING THE PRIMARY HIP SURGERY AND AFTER IMPACTING THE 52MM CUP, IT WAS DISCOVERED THAT THE IMPACTOR HANDLE WOULD NOT DISENGAGE FROM THE CUP. THE SURGEON REMOVED THE ORIGINAL CUP AND IMPLANTED A DIFFERENT 52MM CUP USING A DIFFERENT IMPACTOR HANDLE WITH NO ISSUES. THERE WAS A 5 MINUTE DELAY IN THE CASE AND THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8361559 ↗
Other Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented devices
- PINNACLE 1217-25-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED735 reports
- NA 1365-52-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED683 reports
- APEX 1246-03-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED3 deaths613 reports
- PINNACLE 1217-20-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED2 deaths590 reports
- PINNACLE 1217-30-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED1 death484 reports
- NA 1365-53-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED404 reports
- PINNACLE ALTRX 1221-36-054Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED388 reports
- PINNACLE ALTRX 1221-32-050Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED386 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗