GMK Primary Total Knee System 02.07.0214FUCRecalls & reported problems

Medacta International SA · Tibial insert UC fixed 14mm, size 2 · Class 2 · Implant

All models of GMK Primary Total Knee System (99)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
8
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 07630030816659), received between Jul 21, 2017 and Jul 15, 2025 — classified as 8 injuries.

The most frequently reported specific device problem is “Unstable” (4 reports).

1 other recall cover devices cleared under the same FDA submission (K090988); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Unstable4
  • Loose or Intermittent Connection3
  • Device Appears to Trigger Rejection2
  • Appropriate Device Problem Term/Code Not Available1
  • Device Dislodged or Dislocated1

Patient problems

  • Joint Disorder3
  • Medical device site infection2
  • Joint Dislocation1
  • Joint Laxity1
  • Limited Mobility Of The Implanted Joint1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 15, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    AFTER 2 YEARS AND 6 MONTHS, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON REMOVED ALL PRIMARY COMPONENTS AND REVISED TO A GMK REVISION. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 22506265 ↗
  • InjuryApr 30, 2024Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    AT ABOUT 1 YEAR AND 4 MONTHS AFTER PRIMARY, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 19210982 ↗
  • InjuryJan 12, 2021Unstable

    THE PATIENT CAME IN REPORTING INSTABILITY 4 YEARS AND 10 MONTHS AFTER THE PRIMARY SURGERY. THE SURGEON UPSIZED THE INSERT U.C. 14MM S2 TO AN INSERT U.C. 20MM S2 TO GIVE THE PATIENT MORE STABILITY. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Laxity

    MAUDE report 11153621 ↗
  • InjuryJul 4, 2019Loose or Intermittent Connection; Unstable; Appropriate Device Problem Term/Code Not Available

    REVISION SURGERY PERFORMED AFTER 4 YEARS AND 3 MONTHS AFTER THE PRIMARY DUE TO INSTABILITY CAUSED BY KNEE LAXITY. THE SURGEON PERFORMED A LINER SWAP (SIZE 14MM HAS BEEN EXCHANGED WITH 20 MM) AND RESURFACED THE PATELLA. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Limited Mobility Of The Implanted Joint

    MAUDE report 8762587 ↗
  • InjuryMar 27, 2019Loose or Intermittent Connection

    ABOUT 2 YEARS AND THREE MONTHS AFTER PRIMARY, THE SURGEON REVISED THE PATIENT FOR INSTABILITY DUE TO KNEE LAXITY. THE CAUSE OF LAXITY IS UNKNOWN. THE SURGEON SWAPPED ALL THE HARDWARE SUCCESSFULLY.

    Patient problems: Joint Disorder

    MAUDE report 8456538 ↗
  • InjuryMay 8, 2018Loose or Intermittent Connection; Unstable

    THE PATIENT CAME IN COMPLAINING OF INSTABILITY 8 MONTHS AFTER PRIMARY AND THE 12MM INSERT WAS REVISED WITH A 14MM. THE PATIENT BECAME LOOSE OVER TIME. (MDR 2016-00539) THE PATIENT CAME IN AGAIN 1 YEAR AND 7 MONTHS LATER, COMPLAINING OF ANTERIOR KNEE PAIN. THE PATIENT WAS A LITTLE LOOSE, SO THE 14MM POLY WAS REPLACED WITH A 17MM AND RESURFACED THE PATELLA. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Disorder

    MAUDE report 7494739 ↗
  • InjuryMar 9, 2018Device Dislodged or Dislocated

    THE PATIENT CAME IN DUE TO DISLOCATION. THE SURGEON REVISED THE 14MM INSERT WITH A 17MM INSERT. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Dislocation

    MAUDE report 7326624 ↗
  • InjuryJul 21, 2017Unstable

    THE PATIENT CAME IN COMPLAINING OF INSTABILITY. THE SURGEON CONFIRMS INSTABILITY IN BOTH FLEXION AND EXTENSION. THE SURGEON REVISED THE INSERT AS PLANNED. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Disorder

    MAUDE report 6731750 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K090988. One submission often covers many models, so check the product and lot details in each record.

  • Z-0266-2018 · Oct 24, 2017 · Terminated
    The GMK knee system: designed for cemented use in total knee arthroplasty. Sphere and Primary Inserts with part number ranges: 02.12.0110FL - 02.12.0620FL; 02.12.0110FR - 02.12.0

Other Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices

All Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices →