GMK Revision Total Knee System 02.07.0220SCFRecalls & reported problems

Medacta International SA · Tibial insert SC fixed 20mm, size 2 · Class 2 · Implant

All models of GMK Revision Total Knee System (71)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
7
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 07630030816932), received between Oct 13, 2020 and Mar 16, 2026 — classified as 7 injuries.

The most frequently reported specific device problem is “Device Appears to Trigger Rejection” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Appears to Trigger Rejection3
  • Adverse Event Without Identified Device or Use Problem2
  • Appropriate Device Problem Term/Code Not Available1
  • Unstable1

Patient problems

  • Medical device site infection3
  • Joint Laxity2
  • Loss of Range of Motion1
  • Unspecified Infection1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 16, 2026Device Appears to Trigger Rejection

    REVISION SURGERY DUE TO INFECTION 1 MONTH AFTER THE PRIMARY SURGERY. THE SURGEON PERFORMED A WASHOUT, I&D AND REVISED THE 20MM S2 SEMICONSTRAINED INSERT TO A SAME SIZE INSERT. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 24603550 ↗
  • InjuryJan 15, 2026Device Appears to Trigger Rejection

    THE PATIENT UNDERWENT AN INITIAL KNEE REPLACEMENT OF UNKNOWN DETAILS, INCLUDING IMPLANT TYPE AND HOSPITAL. ON (B)(6) 2025, THE SPACER WAS REMOVED AND MEDACTA REVISION IMPLANTS WERE IMPLANTED (REASON UNKNOWN). DUE TO PERSISTENT INFECTION, A FIRST POLY INSERT EXCHANGE SURGERY WAS PERFORMED ON 2(B)(6) 2025 (02.07.0220SCF, LOT 2317384), FOLLOWED BY A SECOND EXCHANGE ON (B)(6) 2026 (LOT 2118827) FOR THE SAME REASON. A NEW INSERT OF THE SAME SIZE WAS IMPLANTED. NO IMPLANT DEFECTS, LOOSENING, OR SIZING ISSUES WERE IDENTIFIED. INFECTION WITH SUSPECTED BIOFILM ON THE LINER. THE PATIENT HAS SEVERE COMORBIDITIES, INCLUDING BMI 44.1, WITH POTENTIAL RISK OF AMPUTATION.

    Patient problems: Medical device site infection

    MAUDE report 24078376 ↗
  • InjuryNov 18, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    THE PATIENT HAD PRIMARY SURGERY USING COMPETITOR IMPLANTS. ON (B)(6) 2023, THE PATIENT WAS REVISED TO A MEDACTA REVISION SYSTEM. THE SURGERY WAS COMPLETED SUCCESSFULLY. ON (B)(6) 2025, THE PATIENT CAME IN DUE TO AN INFECTION. THE SURGEON PERFORMED A WASHOUT AND REVISED THE POLY. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 23579964 ↗
  • InjuryJun 27, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AT ABOUT 2 YEARS 6 MONTHS AFTER THE MEDACTA PRIMARY, THE PATIENT CAME IN REPORTING PAIN DUE TO A DISLOCATING COMPETITOR'S PATELLA IMPLANT AND A VERY LOOSE MEDIAL COLLATERAL LIGAMENT AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE PATIENT FROM GMK-REVISION TO GMK- HINGE. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Laxity

    MAUDE report 19623608 ↗
  • InjuryJul 7, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT HAD A PRIMARY KNEE SURGERY ON (B)(6) 2022. ON (B)(6) 2022, THE PATIENT CAME IN REPORTING PAIN DUE TO A FRACTURED TIBIA AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE TIBIAL TRAY AND INSERT. THE SURGERY WAS COMPLETED SUCCESSFULLY. PRESENTLY, ON (B)(6) 2023, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE FEMUR AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Loss of Range of Motion

    MAUDE report 17276837 ↗
  • InjuryFeb 10, 2022Appropriate Device Problem Term/Code Not Available

    THE PATIENT HAD A PRIMARY KNEE SURGERY ON (B)(6) 2020. ON (B)(6) 2020, THE SURGEON DECIDED TO RESURFACE THE PATIENT'S PATELLA. THE REASON FOR THIS ADDITIONAL PROCEDURE IS UNKNOWN. THE AGENT WAS NOT NOTIFIED OF THIS PROCEDURE UNTIL PRESENT AND A COMPLAINT WAS NOT FILED. ON (B)(6) 2020, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE LINER. IN 2021, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN WAS UNKNOWN. THE SURGEON REMOVED ALL IMPLANTS AND IMPLANTED A SPACER. THE AGENT WAS NOT AWARE OF THIS PROCEDURE AND MEDACTA IMPLANTS WERE NOT NEEDED ON THIS OCCASION DUE TO THE IMPLANTATION OF THE SPACER. ON (B)(6) 2021, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN WAS UNKNOWN. THE SURGEON REMOVED THE SPACER AND IMPLANTED A HINGE KNEE. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Unspecified Infection

    MAUDE report 13505752 ↗
  • InjuryOct 13, 2020Unstable

    THE PATIENT HAD A PRIMARY SURGERY AND WAS IMPLANTED WITH COMPETITOR PRODUCTS. ON (B)(6) 2020, THE PATIENT HAD THE COMPETITOR PRODUCTS REVISED TO MEDATCA PRODUCTS. THE REASON FOR THE REVISION WAS UNKNOWN. PRESENTLY, ON (B)(6) 2020, 7 MONTHS AFTER PREVIOUS SURGERY, THE PATIENT CAME IN REPORTING INSTABILITY AND THE CAUSE OF THE INSTABILITY IS UNKNOWN. THE SURGEON REVISED ALL GMK-REVISION COMPONENTS TO GMK-HINGE COMPONENTS. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Laxity

    MAUDE report 10669527 ↗

Other Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices

All Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices →