GMK Hinge Total Knee System 02.09.2602LRecalls & reported problems
Medacta International SA · Femoral Component Left, size 2 · Class 2 · Implant
All models of GMK Hinge Total Knee System (55)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 07630030825415), received between Jun 16, 2021 and Jun 24, 2026 — classified as 2 injuries, 1 malfunction.
The most frequently reported specific device problem is “Device Appears to Trigger Rejection” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K130299); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Appropriate Device Problem Term/Code Not Available1
- Device Appears to Trigger Rejection1
Patient problems
- Medical device site infection1
- No Clinical Signs, Symptoms or Conditions1
- Unspecified Infection1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 24, 2026Adverse Event Without Identified Device or Use Problem
DURING SURGERY, AT THE BACK-TABLE ASSEMBLY OF THE GMK HINGE FEMORAL COMPONENT WITH THE OFFSET CONNECTOR, THE WHITE PLASTIC BUSHING WAS FOUND TO BE COVERING THE SCREW HOLE. THE SURGICAL TEAM ATTEMPTED TO LOOSEN AND DISENGAGE THE BUSHING, BUT IT COULD NOT BE RELEASED DESPITE CONSIDERABLE EFFORT. CONSEQUENTLY, THE OFFSET CONNECTION SCREW COULD NOT BE INSERTED. THE SURGEON CONSIDERED THE OFFSET CONNECTOR TAPER LOCK TO BE STABLE AND IMPLANTED THE FEMORAL COMPONENT WITHOUT THE SCREW.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25607357 ↗InjuryDec 11, 2024Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
THE PATIENT HAD PRIMARY SURGERY ON (B)(6) 2021 (COMPETITOR KNEE REVISED, GMK HINGE IMPLANTED). SUBSEQUENTLY, ON (B)(6) 2021, REVISION SURGERY FOR INFECTION AND THE PATHOGEN WAS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND POLY SWAP. ON (B)(6) 2024, REVISION SURGERY FOR INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON REVISED THE FEMORAL COMPONENT, INSERT AND TIBIAL TRAY AND THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Medical device site infection
MAUDE report 20899856 ↗InjuryJun 16, 2021Appropriate Device Problem Term/Code Not Available
4 MONTHS AFTER MEDACTA DEVICES IMPLANTATION REVISION SURGERY FOR INFECTION. THE PATHOGEN IS UNKNOWN. THE SURGEON REMOVED ALL THE IMPLANTS.
Patient problems: Unspecified Infection
MAUDE report 12009447 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K130299. One submission often covers many models, so check the product and lot details in each record.
- Z-2661-2017 · May 19, 2017 · TerminatedMedacta GMK HINGE, Tibial Insert Fixed, SIZE 2, HEIGHT 23 mm, REF 02.09.0223H, STERILE EO
- Z-0275-2016 · Apr 17, 2015 · TerminatedGMK Hinge knee prosthesis; Model Number: 02.09.TA410; Orthopedics and Orthopedic Surgery
Other Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer devices
- ELEOS™ 25001208EOnkos Surgical, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, CONSTRAINED, CEMENTED, METAL/POLYMER3 deaths193 reports
- ELEOS™ THSMWRS01MOnkos Surgical, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, CONSTRAINED, CEMENTED, METAL/POLYMER190 reports
- "UNITED" USTAR II Hip System 1115-1413United Orthopedic Corp. · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer3 recalls3 reports
- "UNITED" USTAR II Hip System 1115-1213United Orthopedic Corp. · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer3 recalls0 reports
- "UNITED" USTAR II Hip System 1115-1417United Orthopedic Corp. · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer3 recalls0 reports
- "UNITED" USTAR II Hip System 1115-1217United Orthopedic Corp. · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer3 recalls0 reports
- Endo-Model Modular Knee Prosthesis System 15-3816/12WALDEMAR LINK GmbH & Co. KG · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer2 recalls6 reports
- Endo-Model Modular Knee Prosthesis System 15-3816/11WALDEMAR LINK GmbH & Co. KG · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer2 recalls6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.