GMK Hinge Total Knee System 02.09.TA310Recalls & reported problems
Medacta International SA · Tibial Augmentation # 3/10mm · Class 2 · Implant
All models of GMK Hinge Total Knee System (55)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07630030825705), received between Jul 19, 2017 and Oct 20, 2017 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Packaging Problem” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K130299); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Packaging Problem1
- Tear, Rip or Hole in Device Packaging1
Patient problems
- No Information1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 20, 2017Packaging Problem; Packaging Problem
WHEN THE TIBIAL AUGMENT WAS OPENED, IT WAS NOTICED THAT THE INNER PACKAGING WAS COMPROMISED. THE SURGEON USED A SECONDARY IMPLANT TO COMPLETE THE SURGERY. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: No Information
MAUDE report 6965054 ↗MalfunctionJul 19, 2017Tear, Rip or Hole in Device Packaging; Tear, Rip or Hole in Device Packaging
WHEN THE TIBIAL AUGMENT WAS OPENED, IT WAS NOTICED THAT THE INTERNAL PACKAGING WAS PUNCTURED. THE SURGEON BELIEVED THE STERILITY WAS NOT COMPROMISED SO HE DECIDED TO IMPLANT THE SUBJECT TIBIAL AUGMENT. ALSO, THE PACKAGING OF THE POSTERIOR FEMORAL WEDGE FOUND WAS FOUND TORN. THE SURGEON DID NOT IMPLANT THE SUBJECT POSTERIOR FEMORAL WEDGE AS HE THOUGHT THE STERILITY MAY BE COMPROMISED. THE SURGEON PROCEEDED USING A SECOND IMPLANT (DIFFERENT SIZE) TO COMPLETE THE CASE. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6724704 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K130299. One submission often covers many models, so check the product and lot details in each record.
- Z-2661-2017 · May 19, 2017 · TerminatedMedacta GMK HINGE, Tibial Insert Fixed, SIZE 2, HEIGHT 23 mm, REF 02.09.0223H, STERILE EO
- Z-0275-2016 · Apr 17, 2015 · TerminatedGMK Hinge knee prosthesis; Model Number: 02.09.TA410; Orthopedics and Orthopedic Surgery
Other Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer devices
- ELEOS™ 25001208EOnkos Surgical, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, CONSTRAINED, CEMENTED, METAL/POLYMER3 deaths193 reports
- ELEOS™ THSMWRS01MOnkos Surgical, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, CONSTRAINED, CEMENTED, METAL/POLYMER190 reports
- "UNITED" USTAR II Hip System 1115-1413United Orthopedic Corp. · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer3 recalls3 reports
- "UNITED" USTAR II Hip System 1115-1213United Orthopedic Corp. · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer3 recalls0 reports
- "UNITED" USTAR II Hip System 1115-1417United Orthopedic Corp. · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer3 recalls0 reports
- "UNITED" USTAR II Hip System 1115-1217United Orthopedic Corp. · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer3 recalls0 reports
- Endo-Model Modular Knee Prosthesis System 15-3816/12WALDEMAR LINK GmbH & Co. KG · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer2 recalls6 reports
- Endo-Model Modular Knee Prosthesis System 15-3816/11WALDEMAR LINK GmbH & Co. KG · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer2 recalls6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page