Skip to content

Mectalif Oblique 03.26.044Recalls & reported problems

Medacta International SA · Oblique Interbody Fusion Device 12x28x9 L5° · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 07630030830631), received between Mar 22, 2019 and Sep 11, 2020 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Device Dislodged or Dislocated1
  • Difficult to Insert1
  • Loose or Intermittent Connection1
  • Migration1

Patient problems

  • Insufficient Information1
  • No Code Available1
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjurySep 11, 2020Loose or Intermittent Connection; Device Dislodged or Dislocated

    PRIMARY SURGERY WAS PERFORMED ON (B)(6) 2020. TLIF SURGERY WAS PERFORMED WITH THE MECTALIF OBLIQUE CAGE AND COMPETITOR'S PEDICLE SCREWS AT L3-L5. PEDICLE SCREW 7MM WAS INSERTED INTO THE L3-L5, AND THE MECTALIF OBLIQUE CAGE H10MM WAS INSERTED INTO THE L3-L5, AND THE MECTALIF OBLIQUE CAGE H9MM WAS INSERTED INTO THE L4-L5. 2 WEEKS AFTER THE PRIMARY SURGERY, THE SURGEON DISCOVERED THE BACK OUT OF THE MECTALIF OBLIQUE CAGE AND THE LOOSENING OF THE PEDICLE SCREW AT L4-L5 BY CT SCAN. REVISION SURGERY WAS PERFORMED ON (B)(6) 2020 (1 MONTH AFTER PRIMARY SURGERY). THE SURGEON REPLACED WITH THE ONE MORE BIGGER SIZE WITH THE ALL PEDICLE SCREWS. THE SURGEON REMOVED THE MECTALIF OBLIQUE CAGE H9M FROM THE PATIENT VERTEBRA, AND INSERTED THE MECTALIF OBLIQUE CAGE 12X28X12 L5°. THE SURGEON IMPACTED THE MECTALIF OBLIQUE CAGE WITH THE HAMMER IN ORDER NOT TO BE BACK OUT AGAIN.

    Patient problems: Insufficient Information

    MAUDE report 10519959 ↗
  • InjuryDec 4, 2019Migration; Migration

    THE SURGEON DISCOVERED THE BACK OUT OF THE OBLIQUE INTERBODY FUSION DEVICE PEEK/TI AT L5-S1. THE PATIENT HAD 2 SURGERIES BEFORE. THIS IS THE SECOND EXPERIENCE OF THE BACK OUT FOR THE SAME PATIENT. THE FIRST SURGERY DATE IS UNKNOWN. THE SECOND SURGERY WAS PERFORMED ON AUGUST 23. NO ADDITIONAL INFO IS AVAILABLE AT THE MOMENT. THE SURGEON SUCCESSFULLY REVISED THE IMPLANT.

    Patient problems: No Code Available

    MAUDE report 9408357 ↗
  • MalfunctionMar 22, 2019Difficult to Insert

    THE NURSE WAS NOT ABLE TO INSERT THE CAGE STRAIGHT WITH THE HANDLE. THE SURGERY WAS FINISHED WITH A BACK UP IMPLANT. 5 MINUTES OF DELAY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8443624 ↗

Other Intervertebral Fusion Device With Bone Graft, Lumbar devices

All Intervertebral Fusion Device With Bone Graft, Lumbar devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page