M.U.S.T. Polyaxial Pedicle Screw 03.50.093Recalls & reported problems

Medacta International SA · Pedicle screw 10x45mm + Nut (1x) - Sterile · Class 2 · Implant

All models of M.U.S.T. Polyaxial Pedicle Screw (25)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07630030834721), received between May 20, 2025 and May 20, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Use of Device Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Use of Device Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 20, 2025Use of Device Problem; Use of Device Problem

    SPINAL FIXATION WAS PERFORMED AT L3-SAI. AFTER INSERTION OF THE ROD, FINAL TIGHTENING WAS PERFORMED, BUT THE RIGHT SIDE OF L5 COULD NOT BE TORQUED PROPERLY. AN OMINOUS NOISE LED THE SURGEON TO CONCLUDE THAT CROSS-THREADING HAD OCCURRED AND REPLACED THE SET SCREW, THEN REINSERTED THE SET SCREW, BUT CROSS-THREADED OCCURED AGAIN. THE SURGEON CONCLUDED THAT THE PEDICLE SCREW HEAD THREADS WERE FAULTY AND REPLACED IT WITH A NEW SCREW (LOT:2229775), COMPLETING THE SURGERY. DUE TO THIS EVENT THE SURGERY WAS PROLONGED ABOUT 1 HOUR AND 30 MINUTES. THE DELAY WAS DUE TO MULTIPLE ATTEMPTS TO INSERT THE SET SCREW ,AND THE SURGEON ONCE REMOVED THE ROD AND THEN REPLACE THE NEW PEDICLE SCREW.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22051616 ↗

Other Appliance, Fixation, Spinal Intervertebral Body devices

All Appliance, Fixation, Spinal Intervertebral Body devices →