Mecta-C Cervical Plate System 03.70.273Recalls & reported problems
Medacta International SA · Fixed self-tapping screw diam. 4x12mm (2x) · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07630030841309), received between May 15, 2019 and May 15, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 15, 2019Break; Break
DURING PRIMARY SPINE SURGERY WAS USED A 2 LEVEL PLATE REQUIRING 6 PIECES OF SCREWS. THE SURGEON PREFERRED THE FIXED SELF-DRILLING SCREWS (LENGTH 12MM, 4,0MM DIAM.). ON THE LEANER SET WERE ONLY 2 X 2 PIECES OF THAT SIZE. THEREFORE HE USED THE SELF-TAPPING SCREWS OF THE SAME LENGTH AND DIAMETER. HE USED THEM IN THE SAME MANNER AS THE SELF-DRILLING SCREWS WITHOUT DRILLING AND TAPPING. WHEN THE SCREW HEAD APPROACHED THE PLATE, THE SURGEON WAS NOT FULLY SATISFIED WITH THE PLACEMENT AND TRIED TO CORRECT THE SCREWS BY USING THE SELF-RETAINING SCREWDRIVER NO.03.70.10.0032. THIS WAS ALSO CAUSED BY THE RETRACTOR IN PLACE INFLUENCING THE ANGULATION OF THE SCREW-INSTRUMENT ASSEMBLY AND THE SCREW TRAJECTORY. BY USING THIS INSTRUMENT HE EXERTED MUCH-BENDING FORCES ON THE ONTO THE SELF-RETAINING SCREWDRIVER THAT RESULTED ON SCREW DAMAGE. THE SURGEON REPLACED THE DAMAGED SCREW BY A 4,5MM RECUE SCREW OF 12MM LENGTH AND THE SURGERY WAS SUCCESSFULLY PERFORMED. THE SURGEON WAS SATISFIED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8612048 ↗
Other Appliance, Fixation, Spinal Intervertebral Body devices
- CD HORIZON® SOLERA® VOYAGER™ Spinal System 6550017Medtronic Sofamor Danek, Inc. · Appliance, fixation, spinal intervertebral body131 reports
- EVEREST® Spinal System 2901-10001VB Spine LLC · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY119 reports
- ZEVO™ Anterior Cervical Plate System 7710015Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall1 report
- XLP 7565050Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- Elegance® Anterior Cervical Plate 53430344Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- ATLANTIS® Anterior Cervical Plate System 876-170Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- XLP 7565060Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- Elegance® Anterior Cervical Plate 53430113Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page