Mpact Double Mobility Shells 01.32.156MBRecalls & reported problems

Medacta International SA · Double Mobility Acetabular shell Ø56 · Class 2 · Implant

Adverse event reports
8
Deaths reported
0
Injuries reported
8
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 07630030860997), received between Jul 21, 2017 and Oct 23, 2024 — classified as 8 injuries.

The most frequently reported specific device problem is “Osseointegration Problem” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Appropriate Device Problem Term/Code Not Available2
  • Osseointegration Problem2
  • Device Slipped1
  • Failure to Osseointegrate1
  • Malposition of Device1
  • Positioning Problem1

Patient problems

  • Inadequate Osseointegration4
  • Joint Disorder2
  • Joint Laxity1
  • Pain1
  • Unspecified Infection1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 23, 2024Osseointegration Problem; Osseointegration Problem

    THE PATIENT HAD HIP INSTABILITY AND THE CAUSE WAS UNKNOWN. AT ABOUT 5 YEARS AND 1 MONTH POST PRIMARY UPON OPENING THE PATIENT, IT WAS OBSERVED THAT THE CUP WAS LOOSE AND THE CAUSE OF THE LOOSE CUP IS UNKNOWN. THE SURGEON REVISED THE CUP, HEAD, AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Inadequate Osseointegration; Joint Laxity

    MAUDE report 20512683 ↗
  • InjuryJun 12, 2024Osseointegration Problem; Osseointegration Problem

    AT ABOUT 4 YEARS AND 4 MONTHS POST PRIMARY REVISION SURGERY FOR MPACT DM LOOSENING. ACETABULAR COMPONENTS AND HEAD WERE REVISED SUCCESSFULLY.

    Patient problems: Inadequate Osseointegration

    MAUDE report 19517427 ↗
  • InjurySep 19, 2023Malposition of Device; Malposition of Device

    AT ABOUT 1 YEAR AND 2 MONTHS FROM THE PRIMARY, THE PATIENT CAME IN REPORTING PAIN DUE TO AN ANTEVERTED CUP AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE MEDACTA CUP AND LINER WITH COMPETITOR COMPONENTS AND REVISED THE MEDACTA HEAD WITH A MEDACTA HEAD. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Pain

    MAUDE report 17773622 ↗
  • InjuryJul 7, 2023Failure to Osseointegrate; Failure to Osseointegrate

    AT ABOUT 1 YEAR AFTER THE PRIMARY, THE PATIENT CAME IN REPORTING PAIN DUE TO A LOOSE CUP AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED SUCCESSFULLY THE MEDACTA CUP, LINER AND HEAD.

    Patient problems: Inadequate Osseointegration

    MAUDE report 17276824 ↗
  • InjuryAug 27, 2020Appropriate Device Problem Term/Code Not Available

    THE PATIENT CAME IN AFTER 1 YEAR AND 5 MONTHS FROM THE PRIMARY FOR A POST-OP APPOINTMENT AND THE SURGEON OBSERVED THAT THE ACETABULAR SHELL WAS NOT WELL FIXED WITHIN THE ACETABULUM. THE SURGEON DECIDED TO REVISE THE PATIENT AND REVISED THE SHELL, LINER, AND FEMORAL CERAMIC HEAD. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Disorder

    MAUDE report 10458657 ↗
  • InjuryOct 31, 2019Positioning Problem

    THE PATIENT CAME IN COMPLAINING OF PAIN, AND THE CAUSE OF THE PAIN WAS A DISLOCATION. POST-OP X-RAYS INDICATED THAT THE CUP WAS PLACED TOO LATERAL WHICH CAUSED A DISLOCATION. THE SURGEON REVISED THE CUP 1 DAY AFTER PRIMARY SURGERY. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Disorder

    MAUDE report 9260078 ↗
  • InjuryJun 14, 2019Device Slipped

    REVISION SURGERY PERFORMED AFTER 1,5 MONTH DUE TO PAIN CAUSED BY A LOOSE CUP. THE SURGEON REVISED THE 56MM MPACT DM CUP WITH A 58MM MPACT TWO HOLE CUP AND ALSO REVISED THE HEAD AND LINER. TE PATIENT WAS DIABETIC. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Inadequate Osseointegration

    MAUDE report 8699599 ↗
  • InjuryJul 21, 2017Appropriate Device Problem Term/Code Not Available

    THE PATIENT WAS REVISED FOR INFECTION. THE SURGEON REVISED ALL MEDACTA COMPONENTS AND IMPLANTED A SPACER. THE SURGERY WAS COMPLETED SUCCESSFULLY. X-RAYS AND EXPLANTS ARE NOT AVAILABLE.

    Patient problems: Unspecified Infection

    MAUDE report 6731941 ↗

Other Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented devices

All Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.