TL 04.1MM RN,S, SLACTIVE TIZR 6, 8, 10, 12, 14, 16MM DENTAL IMPLANTS SLActive Roxolid TL (REF 033.562S)Recalls & reported problems

Institut Straumann AG · Standard Plus Implant, D 4.1mm RN, SLActive® 10mm, Roxolid®, Loxim™ · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Quick summary

This Straumann SLActive Roxolid dental implant has 13,338 adverse event reports, all counted as injuries, and no deaths. Most describe the implant failing to bond with the jawbone, and patients report pain, tissue scarring, tissue damage, infection or inflammation. A few reports describe fractures or implants that are hard to insert. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
13,470
Deaths reported
0
Injuries reported
13,470
Recalls naming it
0

Summary

The FDA's MAUDE database contains 13,470 adverse event reports that list this exact device (DI 07630031715968), received between Sep 9, 2019 and Sep 28, 2026 — classified as 13,470 injuries.

The most frequently reported specific device problem is “Failure to Osseointegrate” (8,648 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 180 reportsJan 2024: 154 reportsFeb 2024: 155 reportsMar 2024: 147 reportsApr 2024: 215 reportsMay 2024: 135 reportsJun 2024: 154 reportsJul 2024: 177 reportsAug 2024: 154 reportsSep 2024: 159 reportsOct 2024: 231 reportsNov 2024: 329 reportsDec 2024: 122 reportsJan 2025: 168 reportsFeb 2025: 137 reportsMar 2025: 190 reportsApr 2025: 48 reportsMay 2025: 0 reportsJun 2025: 469 reportsJul 2025: 157 reportsAug 2025: 156 reportsSep 2025: 105 reportsOct 2025: 112 reportsNov 2025: 209 reportsDec 2025: 161 reportsJan 2026: 185 reportsFeb 2026: 171 reportsMar 2026: 192 reportsApr 2026: 131 reportsMay 2026: 130 reportsJun 2026: 120 reportsJul 2026: 129 reportsAug 2026: 152 reportsSep 2026: 117 reportsOct 2026: 0 reportsNov 2026: 0 reports202420252026469
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate8,648
  • Loss of Osseointegration4,415
  • Adverse Event Without Identified Device or Use Problem368
  • Fracture54
  • Difficult to Insert39
  • Unintended Movement16
  • Unstable14
  • Separation Failure8

Patient problems

  • No Clinical Signs, Symptoms or Conditions5,917
  • Fibrosis4,250
  • Pain2,390
  • Tissue Damage1,727
  • Unspecified Infection1,626
  • Inflammation828
  • Hemorrhage/Blood Loss/Bleeding557
  • Swelling/ Edema452

Recent adverse event reports

The 25 most recent of 13,470 reports, in the reporter's own words as published by the FDA.

  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2025 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922031 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 43. Details of surgery: Ridge augmentation. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50921728 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6)2026 in FDI 43. On (b)(6)2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50921615 ↗
  • InjurySep 28, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2022 in FDI 15. On (b)(6) 2026, loss of osseointegration was verified. Patient presented with bone type III. The device was forwarded to the manufacturer. At the event the patient experienced: Peri-implantitis, Pain, Bleeding and Inflammation. No further patient complications were reported.

    Patient problems: Hemorrhage/Blood Loss/Bleeding; Inflammation; Pain; Unspecified Infection

    MAUDE report 50921479 ↗
  • InjurySep 28, 2026Loss of Osseointegration

    The clinician reports the implant was inserted 2020(b)(6) in FDI 46. On 2026(b)(6), loss of osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Peri-implantitis, Pain, Mobility and Bleeding. No further patient complications were reported.

    Patient problems: Fibrosis; Hemorrhage/Blood Loss/Bleeding; Pain; Unspecified Infection

    MAUDE report 50921478 ↗
  • InjurySep 28, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2024 in the patient's mouth. On (b)(6) 2026, loss of osseointegration was verified. Patient presented with fair oral hygiene. The device was forwarded to the manufacturer. At the event the patient experienced: Pain, Mobility, Bleeding and Fistula. No further patient complications were reported.

    Patient problems: Fibrosis; Fistula; Hemorrhage/Blood Loss/Bleeding; Pain

    MAUDE report 50921463 ↗
  • InjurySep 28, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2023 in FDI 15. On (b)(6) 2026, loss of osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Peri-implantitis, Pain, Swelling and Hypersensitivity. No further patient complications were reported.

    Patient problems: Hypersensitivity/Allergic reaction; Pain; Swelling/ Edema; Unspecified Infection

    MAUDE report 50921408 ↗
  • InjurySep 28, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2023 in FDI 14. On (b)(6) 2026, loss of osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Peri-implantitis, Pain, Swelling and Hypersensitivity. No further patient complications were reported.

    Patient problems: Hypersensitivity/Allergic reaction; Pain; Swelling/ Edema; Unspecified Infection

    MAUDE report 50921407 ↗
  • InjurySep 28, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 24. On (b)(6) 2026, loss of osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Peri-implantitis. No further patient complications were reported.

    Patient problems: Unspecified Infection

    MAUDE report 50921385 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. No product was returned to the manufacturer. At the event the patient experienced: Infection. No further patient complications were reported.

    Patient problems: Unspecified Infection

    MAUDE report 50921219 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6)2026 in the patient's mouth. On (b)(6)2026, non-osseointegration was verified. No product was returned to the manufacturer. At the event the patient experienced: Infection. No further patient complications were reported.

    Patient problems: Unspecified Infection

    MAUDE report 50921218 ↗
  • InjurySep 28, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2010 in FDI 15. On (b)(6) 2026, loss of osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50921199 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 26. Details of surgery: Primary stability not achieved, Implant surface not completely covered with bone and Sinus augmentation. On (b)(6) 2026, non-osseointegration was verified. Patient presented with inadequate bone quality/quantity. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility and Swelling. No further patient complications were reported.

    Patient problems: Fibrosis; Swelling/ Edema

    MAUDE report 50920693 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 15. Details of surgery: Primary stability not achieved, Implant surface not completely covered with bone and Sinus augmentation. On (b)(6) 2026, non-osseointegration was verified. Patient presented with inadequate bone quality/quantity. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility and Swelling. No further patient complications were reported.

    Patient problems: Fibrosis; Swelling/ Edema

    MAUDE report 50920680 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted 2026(b)(6) in FDI 46. On 2026(b)(6), non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50920656 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 34. On 2026-07-21, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50920637 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 25. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50920634 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 36. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50920633 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 47. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50920631 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 15. Details of surgery: Immediate extraction site. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type III. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50920588 ↗
  • InjurySep 28, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2024 in ADA 24. On (b)(6) 2026, loss of osseointegration was verified. No product was returned to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50920569 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 36. On 2026-08-19, non-osseointegration was verified. Patient presented with bone type IV. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50920539 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 16. On (b)(6) 2026, non-osseointegration was verified. Patient presented with fair oral hygiene. No product was returned to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50920531 ↗
  • InjurySep 28, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2022 in FDI 24. On (b)(6) 2026, loss of osseointegration was verified. Patient presented with fair oral hygiene. No product was returned to the manufacturer. There were no patient operative or post-operative complications reported.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50920528 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 46. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type IV. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50920512 ↗

FDA clearance and classification

Cleared through 510(k) K122855 on Dec 12, 2012 (decision: Substantially Equivalent). Submitted by Straumann USA as “Tl 04.1mm Rn,S, Slactive Tizr 6, 8, 10, 12, 14, 16mm Dental Implants”. The FDA review took 85 days. FDA record ↗

The FDA regulates product code DZE (implant, endosseous, root-form) under 21 CFR 872.3640 as a Class II device. 21 CFR 872.3640 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the TL 04.1MM RN,S, SLACTIVE TIZR 6, 8, 10, 12, 14, 16MM DENTAL IMPLANTS SLActive Roxolid TL

Has the TL 04.1MM RN,S, SLACTIVE TIZR 6, 8, 10, 12, 14, 16MM DENTAL IMPLANTS SLActive Roxolid TL been recalled?

No FDA recall record in our data names this exact device identifier (DI 07630031715968), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the TL 04.1MM RN,S, SLACTIVE TIZR 6, 8, 10, 12, 14, 16MM DENTAL IMPLANTS SLActive Roxolid TL?

The FDA's MAUDE database lists 13,470 adverse event reports for this device, received between Sep 9, 2019 and Sep 28, 2026. In those reports, the most common specific device problems are “Failure to Osseointegrate” (8,648), “Loss of Osseointegration” (4,415) and “Fracture” (54); the most common patient problems are “Fibrosis” (4,250), “Pain” (2,390) and “Tissue Damage” (1,727). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the TL 04.1MM RN,S, SLACTIVE TIZR 6, 8, 10, 12, 14, 16MM DENTAL IMPLANTS SLActive Roxolid TL?

None of the reports are classified as deaths, 13,470 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the TL 04.1MM RN,S, SLACTIVE TIZR 6, 8, 10, 12, 14, 16MM DENTAL IMPLANTS SLActive Roxolid TL FDA approved?

It was cleared through 510(k) K122855 on Dec 12, 2012. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the TL 04.1MM RN,S, SLACTIVE TIZR 6, 8, 10, 12, 14, 16MM DENTAL IMPLANTS SLActive Roxolid TL MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the TL 04.1MM RN,S, SLACTIVE TIZR 6, 8, 10, 12, 14, 16MM DENTAL IMPLANTS SLActive Roxolid TL, and is it still sold?

The FDA's device database lists Institut Straumann AG as the company responsible for it (brand TL 04.1MM RN,S, SLACTIVE TIZR 6, 8, 10, 12, 14, 16MM DENTAL IMPLANTS, model SLActive Roxolid TL). Its record shows it as in commercial distribution.