Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid TL (REF 043.260S)Recalls & reported problems
Institut Straumann AG · Standard Plus Implant, D 3.3mm RN, SLA® 8mm, Roxolid®, Loxim™ · Class 2 · Implant
All models of Straumann Dental Implant System Roxolid SLA Impl. (80)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
Quick summary
This Straumann Roxolid SLA dental implant is placed in the jawbone. Reports most often describe the implant failing to fuse with the bone, and some mention scar-like tissue, pain, tissue damage and infection. The device appears in 4,726 reports, with 4,726 injuries and no deaths. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 4,767
- Deaths reported
- 0
- Injuries reported
- 4,767
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4,767 adverse event reports that list this exact device (DI 07630031718976), received between Aug 28, 2019 and Sep 28, 2026 — classified as 4,767 injuries.
The most frequently reported specific device problem is “Failure to Osseointegrate” (3,061 reports).
2 other recalls cover devices cleared under the same FDA submission (K150938); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Osseointegrate3,061
- Loss of Osseointegration1,416
- Fracture185
- Adverse Event Without Identified Device or Use Problem105
- Difficult to Insert13
- Unintended Movement5
- Unstable5
- Difficult to Remove3
Patient problems
- No Clinical Signs, Symptoms or Conditions1,959
- Fibrosis1,548
- Pain1,031
- Tissue Damage610
- Unspecified Infection593
- Hemorrhage/Blood Loss/Bleeding277
- Inflammation224
- Swelling/ Edema149
Recent adverse event reports
The 25 most recent of 4,767 reports, in the reporter's own words as published by the FDA.
InjurySep 28, 2026Loss of Osseointegration
The clinician reports the implant was inserted (b)(6)2024 in the patient's mouth. On (b)(6)2026, loss of osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Peri-implantitis and Mobility. No further patient complications were reported.
Patient problems: Fibrosis; Unspecified Infection
MAUDE report 50921582 ↗InjurySep 28, 2026Loss of Osseointegration
The clinician reports the implant was inserted (b)(6) 2025 in the patient's mouth. On (b)(6) 2026, loss of osseointegration was verified. The device was forwarded to the manufacturer. There were no patient operative or post-operative complications reported.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50921155 ↗InjurySep 28, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in FDI 26. Details of surgery: Sinus augmentation. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Infection and Mobility. No further patient complications were reported.
Patient problems: Fibrosis; Unspecified Infection
MAUDE report 50920064 ↗InjurySep 28, 2026Loss of Osseointegration
The clinician reports the implant was inserted (b)(6) 2025 in ADA 13. On (b)(6) 2026, loss of osseointegration was verified. Patient presented with bone type IV and inadequate bone quality/quantity. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.
Patient problems: Fibrosis
MAUDE report 50919899 ↗InjurySep 28, 2026Loss of Osseointegration
The clinician reports the implant was inserted (b)(6) 2025 in ADA 13. On (b)(6) 2026, loss of osseointegration was verified. Patient presented with bone type IV and inadequate bone quality/quantity. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.
Patient problems: Fibrosis
MAUDE report 50918449 ↗InjurySep 25, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. No product was returned to the manufacturer. There were no reported patient injuries or complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50902042 ↗InjurySep 25, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in FDI 45. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50901992 ↗InjurySep 25, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50901329 ↗InjurySep 24, 2026Loss of Osseointegration
The clinician reports the implant was inserted (b)(6) 2004 in the patient's mouth. On (b)(6) 2026, loss of osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Peri-implantitis. No further patient complications were reported.
Patient problems: Unspecified Infection
MAUDE report 50878751 ↗InjurySep 21, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) in FDI 35. On (b)(6), non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Peri-implantitis and Mobility. No further patient complications were reported.
Patient problems: Fibrosis; Unspecified Infection
MAUDE report 50845296 ↗InjurySep 21, 2026Loss of Osseointegration
The clinician reports the implant was inserted (b)(6) 2026 in ADA 28. Details of surgery: Ridge augmentation. On (b)(6) 2026, loss of osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.
Patient problems: Fibrosis
MAUDE report 50845096 ↗InjurySep 21, 2026Loss of Osseointegration
The clinician reports the implant was inserted (b)(6) 2023 in the patient's mouth. On (b)(6) 2026, loss of osseointegration was verified. Patient presented with fair oral hygiene and previous bone augmentation. No product was returned to the manufacturer. At the event the patient experienced: Pain and Mobility. No further patient complications were reported.
Patient problems: Fibrosis; Pain
MAUDE report 50844366 ↗InjurySep 21, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in FDI 13. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type III. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50844099 ↗InjurySep 21, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. Details of surgery: Primary stability not achieved. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type IV. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.
Patient problems: Fibrosis
MAUDE report 50844020 ↗InjurySep 18, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in FDI 42. Details of surgery: Primary stability not achieved and Implant surface not completely covered with bone. On (b)(6) 2026, non-osseointegration was verified. Patient presented with fair oral hygiene. The device was forwarded to the manufacturer. At the event the patient experienced: Increased Sensitivity. No further patient complications were reported.
Patient problems: Hyperresponsive to stimuli
MAUDE report 50825838 ↗InjurySep 18, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50825160 ↗InjurySep 17, 2026Loss of Osseointegration
The clinician reports the implant was inserted (b)(6) 2026 in FDI 44. On (b)(6) 2026, loss of osseointegration was verified. Patient presented with bone type III. The device was forwarded to the manufacturer. At the event the patient experienced: Peri-implantitis and Mobility. No further patient complications were reported.
Patient problems: Fibrosis; Unspecified Infection
MAUDE report 50806882 ↗InjurySep 14, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6)2026 in the patient's mouth. On (b)(6)2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Pain. No further patient complications were reported.
Patient problems: Pain
MAUDE report 50760782 ↗InjurySep 14, 2026Failure to Osseointegrate
The clinician reports the implant was inserted 2026(b)(6) in the patient's mouth. On 2026(b)(6), non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Pain. No further patient complications were reported.
Patient problems: Pain
MAUDE report 50760780 ↗InjurySep 14, 2026Failure to Osseointegrate
The clinician reports the implant was inserted 2026(b)(6) in the patient's mouth. On 2026(b)(6), non-osseointegration was verified. Patient presented with bone type III. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50760698 ↗InjurySep 14, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in FDI 36. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type III and fair oral hygiene. The device was forwarded to the manufacturer. At the event the patient experienced: Pain. No further patient complications were reported.
Patient problems: Pain
MAUDE report 50760330 ↗InjurySep 14, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in FDI 37. On 2026-07-16, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50759675 ↗InjurySep 14, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in FDI 45. Details of surgery: Primary stability not achieved and Implant surface not completely covered with bone. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50759336 ↗InjurySep 14, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50759309 ↗InjurySep 14, 2026Loss of Osseointegration
The clinician reports the implant was inserted (b)(6) 2026 in FDI 46. On (b)(6) 2026, loss of osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Pain and Mobility. No further patient complications were reported.
Patient problems: Fibrosis; Pain
MAUDE report 50759075 ↗
FDA clearance and classification
Cleared through 510(k) K150938 on Jul 24, 2015 (decision: Substantially Equivalent). Submitted by Straumann USA, LLC as “Straumann® Dental Implant System ¿ Roxolid® SLA Implants”. The FDA review took 108 days. FDA record ↗
The FDA regulates product code DZE (implant, endosseous, root-form) under 21 CFR 872.3640 as a Class II device. 21 CFR 872.3640 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K150938. One submission often covers many models, so check the product and lot details in each record.
- Z-2535-2016 · Jul 14, 2016 · TerminatedStraumann Bone Level Implant, 4.1mm RC, SLA 12mm, TiZr, NTP Article Number: 021.4512
- Z-2534-2016 · Jul 14, 2016 · TerminatedStraumann Bone Level Implant, 4.1mm RC, SLA 10mm, TiZr, NTP Article Number: 021.4510
Common questions about the Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid TL
Has the Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid TL been recalled?
No FDA recall record in our data names this exact device identifier (DI 07630031718976), based on the FDA recall file dated Nov 27, 2026. However, 2 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.
What problems have been reported with the Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid TL?
The FDA's MAUDE database lists 4,767 adverse event reports for this device, received between Aug 28, 2019 and Sep 28, 2026. In those reports, the most common specific device problems are “Failure to Osseointegrate” (3,061), “Loss of Osseointegration” (1,416) and “Fracture” (185); the most common patient problems are “Fibrosis” (1,548), “Pain” (1,031) and “Tissue Damage” (610). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid TL?
None of the reports are classified as deaths, 4,767 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid TL FDA approved?
It was cleared through 510(k) K150938 on Jul 24, 2015. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid TL MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid TL, and is it still sold?
The FDA's device database lists Institut Straumann AG as the company responsible for it (brand Straumann® Dental Implant System Roxolid® SLA Impl., model SLA Roxolid TL). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM43,942 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM40,651 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM27,576 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,756 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLA Titanium BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,548 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM23,631 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,501 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,423 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page