Skip to content

Small Diameter Implant System SLActive Roxolid BL (REF 021.0010)Recalls & reported problems

Institut Straumann AG · Bone Level Tapered Implant, Ø 2.9mm SC, SLActive® 10mm, Roxolid®, Loxim™ · Class 2 · Implant

Quick summary

This Straumann small diameter dental implant is placed in the jawbone to support a replacement tooth. Of its 6,858 reports, all are injury reports and none are deaths. Many describe the implant failing to bond with the bone, and some mention patients with scar-like tissue, infection, pain or inflammation, with a few reports of fractures. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
6,898
Deaths reported
0
Injuries reported
6,898
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6,898 adverse event reports that list this exact device (DI 07630031728005), received between Feb 5, 2018 and Sep 28, 2026 — classified as 6,898 injuries.

The most frequently reported specific device problem is “Failure to Osseointegrate” (5,233 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 96 reportsDec 2023: 100 reportsJan 2024: 69 reportsFeb 2024: 84 reportsMar 2024: 93 reportsApr 2024: 152 reportsMay 2024: 80 reportsJun 2024: 72 reportsJul 2024: 49 reportsAug 2024: 66 reportsSep 2024: 75 reportsOct 2024: 111 reportsNov 2024: 97 reportsDec 2024: 49 reportsJan 2025: 68 reportsFeb 2025: 84 reportsMar 2025: 121 reportsApr 2025: 24 reportsMay 2025: 0 reportsJun 2025: 214 reportsJul 2025: 85 reportsAug 2025: 94 reportsSep 2025: 69 reportsOct 2025: 96 reportsNov 2025: 115 reportsDec 2025: 80 reportsJan 2026: 89 reportsFeb 2026: 59 reportsMar 2026: 98 reportsApr 2026: 103 reportsMay 2026: 72 reportsJun 2026: 79 reportsJul 2026: 88 reportsAug 2026: 70 reportsSep 2026: 52 reportsOct 2026: 0 reports202420252026214
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate5,233
  • Loss of Osseointegration1,058
  • Adverse Event Without Identified Device or Use Problem472
  • Difficult to Insert85
  • Fracture53
  • Separation Failure17
  • Difficult to Remove10
  • Unstable3

Patient problems

  • No Clinical Signs, Symptoms or Conditions2,483
  • Fibrosis2,366
  • Pain1,331
  • Unspecified Infection1,003
  • Tissue Damage903
  • Inflammation592
  • Swelling/ Edema390
  • Fistula361

Recent adverse event reports

The 25 most recent of 6,898 reports, in the reporter's own words as published by the FDA.

  • InjurySep 28, 2026Failure to Osseointegrate

    Patient problems: Pain; Swelling/ Edema

    MAUDE report 50921625 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50921594 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2025 in FDI 33. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50920627 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    Patient problems: Fibrosis

    MAUDE report 50920100 ↗
  • InjurySep 28, 2026Loss of Osseointegration

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50919657 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50918762 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    Patient problems: Fibrosis

    MAUDE report 50918549 ↗
  • InjurySep 18, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50826596 ↗
  • InjurySep 18, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50826582 ↗
  • InjurySep 18, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50825298 ↗
  • InjurySep 18, 2026Failure to Osseointegrate

    Patient problems: Fibrosis

    MAUDE report 50825214 ↗
  • InjurySep 18, 2026Loss of Osseointegration

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50825115 ↗
  • InjurySep 18, 2026Loss of Osseointegration

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50825097 ↗
  • InjurySep 18, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50824986 ↗
  • InjurySep 18, 2026Loss of Osseointegration

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50824966 ↗
  • InjurySep 18, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 23. On (b)(6) 2026, non-osseointegration was verified. Patient presented with inadequate bone quality/quantity. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50824548 ↗
  • InjurySep 18, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 26. On (b)(6) 2026, non-osseointegration was verified. Patient presented with inadequate bone quality/quantity. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50824530 ↗
  • InjurySep 18, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50824369 ↗
  • InjurySep 18, 2026Failure to Osseointegrate

    Patient problems: Fibrosis

    MAUDE report 50824330 ↗
  • InjurySep 18, 2026Loss of Osseointegration

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50824243 ↗
  • InjurySep 18, 2026Loss of Osseointegration

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50824241 ↗
  • InjurySep 18, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50824043 ↗
  • InjurySep 18, 2026Loss of Osseointegration

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50823987 ↗
  • InjurySep 17, 2026Failure to Osseointegrate

    Patient problems: Fibrosis

    MAUDE report 50807752 ↗
  • InjurySep 17, 2026Failure to Osseointegrate

    Patient problems: Unspecified Infection

    MAUDE report 50807675 ↗

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.