Straumann BLX Ø3.5 mm Implants SLActive Roxolid BL (REF 061.3310)Recalls & reported problems

Institut Straumann AG · BLX Implant, Ø 3.5mm RB, SLActive® 10mm, Roxolid® · Class 2 · Implant

All models of Straumann BLX Ø3.5 mm Implants (12)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Quick summary

This Straumann BLX dental implant has 4,216 adverse event reports, all describing injuries and no deaths. The reports mostly describe implants that fail to fuse with the jawbone or later lose their hold, with patients mentioning pain, infection and bleeding. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
4,283
Deaths reported
0
Injuries reported
4,283
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4,283 adverse event reports that list this exact device (DI 07630031743282), received between Jan 28, 2020 and Sep 28, 2026 — classified as 4,283 injuries.

The most frequently reported specific device problem is “Failure to Osseointegrate” (3,152 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 71 reportsJan 2024: 56 reportsFeb 2024: 69 reportsMar 2024: 80 reportsApr 2024: 75 reportsMay 2024: 81 reportsJun 2024: 61 reportsJul 2024: 59 reportsAug 2024: 50 reportsSep 2024: 71 reportsOct 2024: 115 reportsNov 2024: 118 reportsDec 2024: 66 reportsJan 2025: 76 reportsFeb 2025: 54 reportsMar 2025: 74 reportsApr 2025: 33 reportsMay 2025: 0 reportsJun 2025: 194 reportsJul 2025: 79 reportsAug 2025: 71 reportsSep 2025: 65 reportsOct 2025: 91 reportsNov 2025: 81 reportsDec 2025: 99 reportsJan 2026: 79 reportsFeb 2026: 78 reportsMar 2026: 142 reportsApr 2026: 80 reportsMay 2026: 84 reportsJun 2026: 83 reportsJul 2026: 92 reportsAug 2026: 84 reportsSep 2026: 73 reportsOct 2026: 0 reportsNov 2026: 0 reports202420252026194
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate3,152
  • Loss of Osseointegration712
  • Adverse Event Without Identified Device or Use Problem369
  • Difficult to Insert40
  • Fracture11
  • Separation Failure6

Patient problems

  • No Clinical Signs, Symptoms or Conditions2,221
  • Fibrosis1,470
  • Pain818
  • Unspecified Infection490
  • Inflammation260
  • Hemorrhage/Blood Loss/Bleeding197
  • Swelling/ Edema188
  • Hyperresponsive to stimuli141

Recent adverse event reports

The 25 most recent of 4,283 reports, in the reporter's own words as published by the FDA.

  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 23. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50921680 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 5. On (b)(6) 2026, non-osseointegration was verified. No product was returned to the manufacturer. At the event the patient experienced: Pain, Swelling and Fistula. No further patient complications were reported.

    Patient problems: Fistula; Pain; Swelling/ Edema

    MAUDE report 50921634 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 32. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Pain. No further patient complications were reported.

    Patient problems: Pain

    MAUDE report 50921561 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 23. Details of surgery: Implant surface not completely covered with bone. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility and Inflammation. No further patient complications were reported.

    Patient problems: Fibrosis; Inflammation

    MAUDE report 50920704 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2025 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type III, inadequate bone quality/quantity and previous bone augmentation. No product was returned to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50920686 ↗
  • InjurySep 24, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 7. On (b)(6) 2026, loss of osseointegration was verified. Patient presented with bone type III. No product was returned to the manufacturer. At the event the patient experienced: Peri-implantitis and Mobility. No further patient complications were reported.

    Patient problems: Fibrosis; Unspecified Infection

    MAUDE report 50888063 ↗
  • InjurySep 24, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. Patient presented with inadequate bone quality/quantity. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50888024 ↗
  • InjurySep 24, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) in the patient's mouth. On (b)(6), non-osseointegration was verified. Patient presented with inadequate bone quality/quantity. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50888019 ↗
  • InjurySep 24, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 7. On (b)(6) 2026, loss of osseointegration was verified. The device was forwarded to the manufacturer. There were no patient operative or post-operative complications reported.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50887833 ↗
  • InjurySep 24, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2025 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. No product was returned to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50887552 ↗
  • InjurySep 21, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 28. Details of surgery: Implant surface not completely covered with bone. On (b)(6) 2026, non-osseointegration was verified. Patient presented with previous bone augmentation. The device was forwarded to the manufacturer. At the event the patient experienced: Abscess. No further patient complications were reported.

    Patient problems: Abscess

    MAUDE report 50845229 ↗
  • InjurySep 21, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2025 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50844384 ↗
  • InjurySep 21, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2025 in FDI 15. On (b)(6) 2026, loss of osseointegration was verified. No product was returned to the manufacturer. There were no patient operative or post-operative complications reported.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50844043 ↗
  • InjurySep 21, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2025 in FDI 14. On (b)(6) 2026, loss of osseointegration was verified. No product was returned to the manufacturer. There were no patient operative or post-operative complications reported.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50844039 ↗
  • InjurySep 18, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 12. Details of surgery: Ridge augmentation. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50826527 ↗
  • InjurySep 18, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 32. On (b)(6) 2026, non-osseointegration was verified. Patient presented with fair oral hygiene. The device was forwarded to the manufacturer. At the event the patient experienced: Pain, Mobility and Inflammation. No further patient complications were reported.

    Patient problems: Fibrosis; Inflammation; Pain

    MAUDE report 50826137 ↗
  • InjurySep 18, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted(b)(6)2025 in FDI 12. On(b)(6)2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50824898 ↗
  • InjurySep 17, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type III. No product was returned to the manufacturer. At the event the patient experienced: Pain and Mobility. No further patient complications were reported.

    Patient problems: Fibrosis; Pain

    MAUDE report 50807807 ↗
  • InjurySep 14, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 26. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50760523 ↗
  • InjurySep 14, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted 2026(b)(6) in the patient's mouth. On 2026(b)(6), non-osseointegration was verified. Patient presented with bone type III. The device was forwarded to the manufacturer. At the event the patient experienced: Pain and Increased Sensitivity. No further patient complications were reported.

    Patient problems: Hyperresponsive to stimuli; Pain

    MAUDE report 50760427 ↗
  • InjurySep 14, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 46. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Infection, Peri-implantitis, Pain, Mobility, Fistula and Inflammation. No further patient complications were reported.

    Patient problems: Fibrosis; Fistula; Inflammation; Pain; Unspecified Infection

    MAUDE report 50760416 ↗
  • InjurySep 14, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted 2026(b)(6) in ADA 12. On 2026(b)(6), non-osseointegration was verified. Patient presented with inadequate bone quality/quantity. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50759732 ↗
  • InjurySep 14, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 7. Details of surgery: Primary stability not achieved and Immediate extraction site. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type IV and fair oral hygiene. The device was forwarded to the manufacturer. At the event the patient experienced: Pain and Mobility. No further patient complications were reported.

    Patient problems: Fibrosis; Pain

    MAUDE report 50759566 ↗
  • InjurySep 14, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 28. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type III. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50759556 ↗
  • InjurySep 14, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted 2026(b)(6) in the patient's mouth. On 2026(b)(6), non-osseointegration was verified. No product was returned to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50759407 ↗

FDA clearance and classification

Cleared through 510(k) K191256 on Dec 27, 2019 (decision: Substantially Equivalent). Submitted by Institut Straumann AG as “Straumann BLX Ø3.5 mm Implants”. The FDA review took 231 days. FDA record ↗

The FDA regulates product code DZE (implant, endosseous, root-form) under 21 CFR 872.3640 as a Class II device. 21 CFR 872.3640 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Straumann BLX Ø3.5 mm Implants SLActive Roxolid BL

Has the Straumann BLX Ø3.5 mm Implants SLActive Roxolid BL been recalled?

No FDA recall record in our data names this exact device identifier (DI 07630031743282), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Straumann BLX Ø3.5 mm Implants SLActive Roxolid BL?

The FDA's MAUDE database lists 4,283 adverse event reports for this device, received between Jan 28, 2020 and Sep 28, 2026. In those reports, the most common specific device problems are “Failure to Osseointegrate” (3,152), “Loss of Osseointegration” (712) and “Difficult to Insert” (40); the most common patient problems are “Fibrosis” (1,470), “Pain” (818) and “Unspecified Infection” (490). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Straumann BLX Ø3.5 mm Implants SLActive Roxolid BL?

None of the reports are classified as deaths, 4,283 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Straumann BLX Ø3.5 mm Implants SLActive Roxolid BL FDA approved?

It was cleared through 510(k) K191256 on Dec 27, 2019. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the Straumann BLX Ø3.5 mm Implants SLActive Roxolid BL MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the Straumann BLX Ø3.5 mm Implants SLActive Roxolid BL, and is it still sold?

The FDA's device database lists Institut Straumann AG as the company responsible for it (brand Straumann BLX Ø3.5 mm Implants, model SLActive Roxolid BL). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →