Skip to content

Straumann BLX Line Extension - Implants, SRAs And Anatomic Abutments SLA Roxolid BL (REF 061.4512)Recalls & reported problems

Institut Straumann AG · BLX Implant, Ø 3.75mm RB, SLA® 12mm, Roxolid® · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Straumann BLX implant is a screw placed in the jawbone to hold a replacement tooth. Of its 1,705 reports, all filed as injuries, most describe the implant failing to fuse with the bone or later losing that bond. Reports also mention scar-like tissue, pain, infection and swelling. There are no deaths reported, and no recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
1,720
Deaths reported
0
Injuries reported
1,720
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1,720 adverse event reports that list this exact device (DI 07630031743466), received between Aug 17, 2020 and Sep 28, 2026 — classified as 1,720 injuries.

The most frequently reported specific device problem is “Failure to Osseointegrate” (1,323 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 26 reportsDec 2023: 34 reportsJan 2024: 32 reportsFeb 2024: 22 reportsMar 2024: 27 reportsApr 2024: 38 reportsMay 2024: 28 reportsJun 2024: 27 reportsJul 2024: 23 reportsAug 2024: 35 reportsSep 2024: 22 reportsOct 2024: 35 reportsNov 2024: 31 reportsDec 2024: 39 reportsJan 2025: 35 reportsFeb 2025: 17 reportsMar 2025: 32 reportsApr 2025: 18 reportsMay 2025: 0 reportsJun 2025: 83 reportsJul 2025: 36 reportsAug 2025: 43 reportsSep 2025: 25 reportsOct 2025: 38 reportsNov 2025: 45 reportsDec 2025: 59 reportsJan 2026: 27 reportsFeb 2026: 31 reportsMar 2026: 52 reportsApr 2026: 34 reportsMay 2026: 51 reportsJun 2026: 44 reportsJul 2026: 34 reportsAug 2026: 30 reportsSep 2026: 25 reportsOct 2026: 0 reports20242025202683
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate1,323
  • Loss of Osseointegration241
  • Adverse Event Without Identified Device or Use Problem135
  • Difficult to Insert18
  • Fracture4
  • Separation Failure1

Patient problems

  • No Clinical Signs, Symptoms or Conditions867
  • Fibrosis590
  • Pain345
  • Unspecified Infection276
  • Inflammation109
  • Swelling/ Edema86
  • Hemorrhage/Blood Loss/Bleeding70
  • Fistula47

Recent adverse event reports

The 25 most recent of 1,720 reports, in the reporter's own words as published by the FDA.

  • InjurySep 28, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2022 in the patient's mouth. On (b)(6) 2026, loss of osseointegration was verified. The device was forwarded to the manufacturer. There were no patient operative or post-operative complications reported.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50921445 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6)2026 in ADA 24. On (b)(6)2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Peri-implantitis, Pain, Swelling and Inflammation. No further patient complications were reported.

    Patient problems: Inflammation; Pain; Swelling/ Edema; Unspecified Infection

    MAUDE report 50920503 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50920453 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    Patient problems: Fibrosis; Unspecified Infection

    MAUDE report 50920311 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50919508 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 24. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Peri-implantitis, Pain, Swelling and Inflammation. No further patient complications were reported.

    Patient problems: Inflammation; Pain; Swelling/ Edema; Unspecified Infection

    MAUDE report 50918709 ↗
  • InjurySep 17, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50806926 ↗
  • InjurySep 16, 2026Adverse Event Without Identified Device or Use Problem

    The clinician reports that the day the implant was placed in FDI 12, failure occurred upon insertion. Details of surgery: Primary stability not achieved and Implant surface not completely covered with bone. Patient presented with bone type IV. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50792067 ↗
  • InjurySep 14, 2026Loss of Osseointegration

    Patient problems: Pain

    MAUDE report 50761031 ↗
  • InjurySep 14, 2026Loss of Osseointegration

    Patient problems: Fibrosis; Hypersensitivity/Allergic reaction; Inflammation; Pain; Unspecified Infection

    MAUDE report 50760492 ↗
  • InjurySep 14, 2026Adverse Event Without Identified Device or Use Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50759270 ↗
  • InjurySep 14, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (B)(6) 2025 in ADA 9. On (B)(6) 2026, loss of osseointegration was verified. Patient presented with fair oral hygiene. The device was forwarded to the manufacturer. At the event the patient experienced: Pain. No further patient complications were reported.

    Patient problems: Pain

    MAUDE report 50758032 ↗
  • InjurySep 14, 2026Loss of Osseointegration

    Patient problems: Fibrosis; Hypersensitivity/Allergic reaction; Inflammation; Pain; Unspecified Infection

    MAUDE report 50757879 ↗
  • InjurySep 11, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50739051 ↗
  • InjurySep 11, 2026Failure to Osseointegrate

    Patient problems: Unspecified Infection

    MAUDE report 50739043 ↗
  • InjurySep 10, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50719089 ↗
  • InjurySep 10, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50718940 ↗
  • InjurySep 7, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50655346 ↗
  • InjurySep 7, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50655344 ↗
  • InjurySep 7, 2026Loss of Osseointegration

    Patient problems: Fibrosis

    MAUDE report 50654084 ↗
  • InjurySep 7, 2026Failure to Osseointegrate

    Patient problems: Unspecified Infection

    MAUDE report 50653945 ↗
  • InjurySep 7, 2026Failure to Osseointegrate

    Patient problems: Pain; Unspecified Infection

    MAUDE report 50653932 ↗
  • InjurySep 7, 2026Loss of Osseointegration

    Patient problems: Fibrosis

    MAUDE report 50653071 ↗
  • InjurySep 7, 2026Failure to Osseointegrate

    Patient problems: Unspecified Infection

    MAUDE report 50652991 ↗
  • InjurySep 7, 2026Failure to Osseointegrate

    Patient problems: Pain; Unspecified Infection

    MAUDE report 50652968 ↗

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page