Straumann BLX Implant System SLA Roxolid BL (REF 061.5514)Recalls & reported problems
Institut Straumann AG · BLX Implant, Ø 4.0mm RB, SLA® 14mm, Roxolid® · Class 2 · Implant
All models of Straumann BLX Implant System (60)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
Quick summary
This Straumann BLX dental implant is a post placed in the jawbone to hold a replacement tooth. Most of its 470 reports describe implants that failed to bond with the bone or later lost that bond, with patients also mentioning pain, infection and swelling. All 470 are injury reports, and there are no deaths. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 481
- Deaths reported
- 0
- Injuries reported
- 481
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 481 adverse event reports that list this exact device (DI 07630031743619), received between Jan 4, 2021 and Sep 28, 2026 — classified as 481 injuries.
The most frequently reported specific device problem is “Failure to Osseointegrate” (326 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Osseointegrate326
- Loss of Osseointegration80
- Adverse Event Without Identified Device or Use Problem65
- Difficult to Insert10
Patient problems
- No Clinical Signs, Symptoms or Conditions245
- Fibrosis175
- Pain74
- Unspecified Infection64
- Inflammation28
- Swelling/ Edema26
- Hemorrhage/Blood Loss/Bleeding19
- Fistula10
Recent adverse event reports
The 25 most recent of 481 reports, in the reporter's own words as published by the FDA.
InjurySep 28, 2026Adverse Event Without Identified Device or Use Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50921243 ↗InjurySep 17, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (B)(6) 2025 in FDI 22. Details of surgery: Ridge augmentation. On (B)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Peri-implantitis and Mobility. No further patient complications were reported.
Patient problems: Fibrosis; Unspecified Infection
MAUDE report 50806913 ↗InjurySep 10, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (B)(6) 2025 in the patient's mouth. On (B)(6) 2026, non-osseointegration was verified. No product was returned to the manufacturer. There were no reported patient injuries or complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50719034 ↗InjurySep 7, 2026Failure to Osseointegrate
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50654726 ↗InjurySep 7, 2026Failure to Osseointegrate
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50654572 ↗InjurySep 7, 2026Adverse Event Without Identified Device or Use Problem
Patient problems: Fibrosis
MAUDE report 50654079 ↗InjurySep 7, 2026Adverse Event Without Identified Device or Use Problem
Patient problems: Fibrosis
MAUDE report 50653079 ↗InjuryAug 24, 2026Failure to Osseointegrate
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50414220 ↗InjuryAug 17, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in FDI 22. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50284170 ↗InjuryAug 17, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. No product was returned to the manufacturer. There were no reported patient injuries or complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50283380 ↗InjuryAug 17, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (B)(6) 2025 in the patient's mouth. Details of surgery: Implant surface not completely covered with bone, Ridge augmentation and Immediate extraction site. On (B)(6) 2026, non-osseointegration was verified. Patient presented with bone type III and inadequate bone quality/quantity. No product was returned to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.
Patient problems: Fibrosis
MAUDE report 50282272 ↗InjuryAug 3, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. No product was returned to the manufacturer. At the event the patient experienced: Infection, Peri-implantitis and Mobility. No further patient complications were reported.
Patient problems: Fibrosis; Unspecified Infection
MAUDE report 50120299 ↗InjuryAug 3, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in FDI 14. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type III. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.
Patient problems: Fibrosis
MAUDE report 50119288 ↗InjuryJul 31, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (B)(6) 2026 in the patient's mouth. On (B)(6) 2026, non-osseointegration was verified. No product was returned to the manufacturer. There were no reported patient injuries or complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50103074 ↗InjuryJul 31, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in ADA 10. Details of surgery: Implant surface not completely covered with bone. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type III. The device was forwarded to the manufacturer. At the event the patient experienced: Infection and Mobility. No further patient complications were reported.
Patient problems: Fibrosis; Unspecified Infection
MAUDE report 50102967 ↗InjuryJul 31, 2026Loss of Osseointegration
The clinician reports the implant was inserted (b)(6) 2025 in ADA 3. On (b)(6) 2026, loss of osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.
Patient problems: Fibrosis
MAUDE report 50102764 ↗InjuryJul 31, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in ADA 10. Details of surgery: Implant surface not completely covered with bone. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type III. The device was forwarded to the manufacturer. At the event the patient experienced: Infection and Mobility. No further patient complications were reported.
Patient problems: Fibrosis; Unspecified Infection
MAUDE report 50102267 ↗InjuryJul 31, 2026Loss of Osseointegration
The clinician reports the implant was inserted (b)(6) 2025 in ADA 3. On (b)(6) 2026, loss of osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.
Patient problems: Fibrosis
MAUDE report 50102118 ↗InjuryJul 30, 2026Failure to Osseointegrate
The clinician reports the implant was inserted on (b)(6)2026 in FDI 16. On 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50088056 ↗InjuryJul 27, 2026Adverse Event Without Identified Device or Use Problem
The clinician reports that the day the implant was placed in ADA 3, failure occurred upon insertion. Details of surgery: Primary stability not achieved and Immediate extraction site. Patient presented with bone type III and inadequate bone quality/quantity. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.
Patient problems: Fibrosis
MAUDE report 50040961 ↗InjuryJul 27, 2026Failure to Osseointegrate
The clinician reports the implant was inserted (b)(6) 2026 in ADA 13. Details of surgery: Implant surface not completely covered with bone and Ridge augmentation. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Peri-implantitis. No further patient complications were reported.
Patient problems: Unspecified Infection
MAUDE report 50040929 ↗InjuryJul 27, 2026Failure to Osseointegrate
The clinician reports the implant was inserted 2026 (b)(6) in ADA 13. Details of surgery: Implant surface not completely covered with bone and Ridge augmentation. On 2026 (b)(6), non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Peri-implantitis. No further patient complications were reported.
Patient problems: Unspecified Infection
MAUDE report 50039500 ↗InjuryJul 9, 2026Failure to Osseointegrate
THE CLINICIAN REPORTS THE IMPLANT WAS INSERTED ON (B)(6) 2025 IN THE PATIENT'S MOUTH. ON (B)(6) 2026, NON-OSSEOINTEGRATION WAS VERIFIED. NO PRODUCT WAS RETURNED TO THE MANUFACTURER. THERE WERE NO REPORTED PATIENT INJURIES OR COMPLICATIONS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25768494 ↗InjuryJul 8, 2026Failure to Osseointegrate
THE CLINICIAN REPORTS THE IMPLANT WAS INSERTED (B)(6) 2026 IN THE PATIENT'S MOUTH. ON (B)(6) 2026, NON-OSSEOINTEGRATION WAS VERIFIED. NO PRODUCT WAS RETURNED TO THE MANUFACTURER. THERE WERE NO REPORTED PATIENT INJURIES OR COMPLICATIONS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25751519 ↗InjuryJul 6, 2026Failure to Osseointegrate
THE CLINICIAN REPORTS THE IMPLANT WAS INSERTED (B)(6) 2026 IN THE PATIENT'S MOUTH. ON (B)(6) 2026 NON-OSSEOINTEGRATION WAS VERIFIED. THE DEVICE WAS FORWARDED TO THE MANUFACTURER. THERE WERE NO REPORTED PATIENT INJURIES OR COMPLICATIONS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25721574 ↗
Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM43,616 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM40,404 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM27,400 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,621 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLA Titanium BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,298 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM23,448 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,320 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,267 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026