Straumann® BLC and TLC Implants SLActive Roxolid BL (REF 035.9810S)Recalls & reported problems

Institut Straumann AG · BLC Implant, Ø 6.5mm WB, SLActive® 10mm, Roxolid® · Class 2 · Implant

All models of Straumann BLC and TLC Implants (153)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Quick summary

This Straumann BLC dental implant is a root-form implant placed in the jawbone. The 446 reports often describe implants that did not bond with the bone or did not hold firmly when placed, and some describe bleeding and mobility problems after surgery. There are 446 injuries and no deaths, and no recalls name this device. Reports rose from 174 in the year before to 254 in the most recent year.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
439
Deaths reported
0
Injuries reported
439
Recalls naming it
0

Summary

The FDA's MAUDE database contains 439 adverse event reports that list this exact device (DI 07630031764683), received between Jul 1, 2024 and Sep 28, 2026 — classified as 439 injuries.

The most frequently reported specific device problem is “Failure to Osseointegrate” (218 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 8 reportsSep 2024: 2 reportsOct 2024: 7 reportsNov 2024: 7 reportsDec 2024: 4 reportsJan 2025: 11 reportsFeb 2025: 4 reportsMar 2025: 20 reportsApr 2025: 2 reportsMay 2025: 0 reportsJun 2025: 40 reportsJul 2025: 15 reportsAug 2025: 31 reportsSep 2025: 14 reportsOct 2025: 26 reportsNov 2025: 25 reportsDec 2025: 33 reportsJan 2026: 13 reportsFeb 2026: 14 reportsMar 2026: 40 reportsApr 2026: 27 reportsMay 2026: 35 reportsJun 2026: 15 reportsJul 2026: 18 reportsAug 2026: 22 reportsSep 2026: 5 reportsOct 2026: 0 reports20242025202640
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate218
  • Adverse Event Without Identified Device or Use Problem158
  • Loss of Osseointegration53
  • Difficult to Insert14
  • Separation Failure2

Patient problems

  • No Clinical Signs, Symptoms or Conditions262
  • Fibrosis147
  • Pain58
  • Unspecified Infection42
  • Hemorrhage/Blood Loss/Bleeding12
  • Inflammation12
  • Abscess10
  • Swelling/ Edema9

Recent adverse event reports

The 25 most recent of 439 reports, in the reporter's own words as published by the FDA.

  • InjurySep 28, 2026Difficult to Insert

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50920337 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50919808 ↗
  • InjurySep 28, 2026Difficult to Insert

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50918631 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50918352 ↗
  • InjurySep 7, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50654500 ↗
  • InjuryAug 27, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 19. Details of surgery: Implant surface not completely covered with bone. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type III and inadequate bone quality/quantity. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility and Bleeding. No further patient complications were reported.

    Patient problems: Fibrosis; Hemorrhage/Blood Loss/Bleeding

    MAUDE report 50481398 ↗
  • InjuryAug 27, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted on (b)(6)2026 in ADA 2. Details of surgery: Sinus augmentation and Ridge augmentation. On (b)(6)2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility and Bleeding. No further patient complications were reported.

    Patient problems: Fibrosis; Hemorrhage/Blood Loss/Bleeding

    MAUDE report 50481397 ↗
  • InjuryAug 27, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 19. Details of surgery: Implant surface not completely covered with bone. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type III and inadequate bone quality/quantity. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility and Bleeding. No further patient complications were reported.

    Patient problems: Fibrosis; Hemorrhage/Blood Loss/Bleeding

    MAUDE report 50480372 ↗
  • InjuryAug 27, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 2. Details of surgery: Sinus augmentation and Ridge augmentation. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility and Bleeding. No further patient complications were reported.

    Patient problems: Fibrosis; Hemorrhage/Blood Loss/Bleeding

    MAUDE report 50480371 ↗
  • InjuryAug 24, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6)2026 in ADA 7. On (b)(6)2026, non-osseointegration was verified. No product was returned to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50416932 ↗
  • InjuryAug 24, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 19. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50416783 ↗
  • InjuryAug 24, 2026Failure to Osseointegrate

    Patient problems: Fibrosis; Pain

    MAUDE report 50415991 ↗
  • InjuryAug 24, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 30. Details of surgery: Primary stability not achieved and Implant surface not completely covered with bone. On 2026-07-14, non-osseointegration was verified. Patient presented with bone type III. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50415164 ↗
  • InjuryAug 24, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted on (b)(6) 2026 in ADA 19. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50413641 ↗
  • InjuryAug 24, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (B)(6) 2026 in ADA 7. On (B)(6) 2026 non-osseointegration was verified. No product was returned to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50413632 ↗
  • InjuryAug 24, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 30. Details of surgery: Primary stability not achieved and Implant surface not completely covered with bone. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type III. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50413334 ↗
  • InjuryAug 17, 2026Adverse Event Without Identified Device or Use Problem

    The clinician reports that the day the implant was placed in ADA 19, failure occurred upon insertion. Details of surgery: Primary stability not achieved and Immediate extraction site. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50283727 ↗
  • InjuryAug 17, 2026Adverse Event Without Identified Device or Use Problem

    The clinician reports that the day the implant was placed in ADA 19, failure occurred upon insertion. Details of surgery: Primary stability not achieved, Implant surface not completely covered with bone and Ridge augmentation. Patient presented with inadequate bone quality/quantity and previous bone augmentation. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50283578 ↗
  • InjuryAug 17, 2026Adverse Event Without Identified Device or Use Problem

    The clinician reports that the day the implant was placed in ADA 19, failure occurred upon insertion. Details of surgery: Primary stability not achieved and Immediate extraction site. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50281320 ↗
  • InjuryAug 17, 2026Adverse Event Without Identified Device or Use Problem

    The clinician reports that the day the implant was placed in ADA 19, failure occurred upon insertion. Details of surgery: Primary stability not achieved, Implant surface not completely covered with bone and Ridge augmentation. Patient presented with inadequate bone quality/quantity and previous bone augmentation. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50281232 ↗
  • InjuryAug 14, 2026Difficult to Insert

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50258837 ↗
  • InjuryAug 14, 2026Difficult to Insert

    The clinician reports that the day the implant was placed in ADA 31, failure occurred upon insertion. Details of surgery: Primary stability not achieved and Implant surface not completely covered with bone. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50258254 ↗
  • InjuryAug 7, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 3. On (b)(6) 2026, non-osseointegration was verified. No product was returned to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50179422 ↗
  • InjuryAug 7, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 3. On (b)(6) 2026, non-osseointegration was verified. No product was returned to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50178569 ↗
  • InjuryAug 6, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50162806 ↗