Shoulder System 04.01.0111Recalls & reported problems

Medacta International SA · Humeral reverse metaphysis +9mm/0° · Class 2 · Implant

All models of Shoulder System (63)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
8
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 07630040706186), received between Dec 15, 2017 and Nov 28, 2025 — classified as 8 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Device Dislodged or Dislocated3
  • Device Appears to Trigger Rejection1
  • Loosening of Implant Not Related to Bone-Ingrowth1
  • Unstable1

Patient problems

  • Joint Dislocation3
  • Joint Laxity3
  • Loss of Range of Motion1
  • Unspecified Infection1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ON (B)(6) 2023, THE PATIENT HAD PRIMARY LEFT SHOULDER SURGERY. ON (B)(6) 2025, THE PATIENT CAME IN REPORTING A WITH TIGHT SHOULDER AND LIMITED MOBILITY AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE GLENOSPHERE, LINER, AND METAPHYSIS. THE SURGERY WAS COMPLETED SUCCESSFULLY (B)(4). ON (B)(6) 2025, THE PATIENT CAME IN REPORTING STABILITY ISSUES AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE METAPHYSIS AND UPSIZED THE LINER AND GLENOSPHERE. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Laxity

    MAUDE report 23669504 ↗
  • InjuryJul 30, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated

    AT ABOUT 5 MONTHS AFTER THE PRIMARY SURGERY, THE PATIENT REPORTED PAIN DUE TO A DISLOCATION OF THE LINER FROM THE GLENOSPHERE. THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE LINER, METAPHYSIS, AND GLENOSPHERE. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Dislocation

    MAUDE report 22664404 ↗
  • InjuryApr 4, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT HAD A PRIMARY SHOULDER SURGERY ON (B)(6) 2024. ON (B)(6) 2024, THE PATIENT CAME IN REPORTING PAIN DUE TO A DISLOCATION OF THE LINER FROM THE GLENOSPHERE AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE METAPHYSIS AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY. ON (B)(6) 2025, THE PATIENT CAME IN REPORTING INSTABILITY AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE GLENOSPHERE, METAPHYSIS, AND LINER. THER SURGERY WAS COMPLETE SUCCESSFULLY.

    Patient problems: Joint Laxity

    MAUDE report 21771468 ↗
  • InjuryMar 17, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AT ABOUT 1 YEAR AND 6 MONTHS AFTER PRIMARY, THE PATIENT CAME IN REPORTING STIFFNESS AND LIMITED MOBILITY AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE GLENOSPHERE, LINER AND METAPHYSIS. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Loss of Range of Motion

    MAUDE report 21617414 ↗
  • InjuryApr 8, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    AT 3 YEARS AND 5 MONTHS FROM THE PRIMARY, THE PATIENT CAME IN REPORTING INSTABILITY AND THE CAUSE IS UNKNOWN. THE SURGEON UPSIZED THE GLENOSPHERE, LINER, AND METAPHYSIS. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Dislocation

    MAUDE report 19059643 ↗
  • InjuryMar 23, 2023Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    AT ABOUT 1 MONTH AFTER THE PRIMARY SURGERY, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON REVISED THE COMPETITOR GLENOSPHERE AND MEDACTA METAPHYSIS AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Unspecified Infection

    MAUDE report 16596968 ↗
  • InjuryOct 19, 2021Unstable; Loosening of Implant Not Related to Bone-Ingrowth

    THE PATIENT CAME IN REPORTING LATERAL INSTABILITY AND THE CAUSE OF THE INSTABILITY IS LAXITY. ABOUT 1 MONTH AND A HALF AFTER THE PRIMARY SURGERY, THE SURGEON REVISED THE GLENOSPHERE, LINER, AND METAPHYSIS. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Laxity

    MAUDE report 12655740 ↗
  • InjuryDec 15, 2017Device Dislodged or Dislocated

    REVISION SURGERY WAS NECESSARY DUE TO LUXATION.

    Patient problems: Joint Dislocation

    MAUDE report 7120560 ↗

Other Shoulder Prosthesis, Reverse Configuration devices

All Shoulder Prosthesis, Reverse Configuration devices →