Shoulder System 04.01.0111Recalls & reported problems
Medacta International SA · Humeral reverse metaphysis +9mm/0° · Class 2 · Implant
All models of Shoulder System (63)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 8
- Deaths reported
- 0
- Injuries reported
- 8
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 07630040706186), received between Dec 15, 2017 and Nov 28, 2025 — classified as 8 injuries.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem3
- Device Dislodged or Dislocated3
- Device Appears to Trigger Rejection1
- Loosening of Implant Not Related to Bone-Ingrowth1
- Unstable1
Patient problems
- Joint Dislocation3
- Joint Laxity3
- Loss of Range of Motion1
- Unspecified Infection1
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
InjuryNov 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ON (B)(6) 2023, THE PATIENT HAD PRIMARY LEFT SHOULDER SURGERY. ON (B)(6) 2025, THE PATIENT CAME IN REPORTING A WITH TIGHT SHOULDER AND LIMITED MOBILITY AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE GLENOSPHERE, LINER, AND METAPHYSIS. THE SURGERY WAS COMPLETED SUCCESSFULLY (B)(4). ON (B)(6) 2025, THE PATIENT CAME IN REPORTING STABILITY ISSUES AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE METAPHYSIS AND UPSIZED THE LINER AND GLENOSPHERE. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Joint Laxity
MAUDE report 23669504 ↗InjuryJul 30, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated
AT ABOUT 5 MONTHS AFTER THE PRIMARY SURGERY, THE PATIENT REPORTED PAIN DUE TO A DISLOCATION OF THE LINER FROM THE GLENOSPHERE. THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE LINER, METAPHYSIS, AND GLENOSPHERE. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Joint Dislocation
MAUDE report 22664404 ↗InjuryApr 4, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT HAD A PRIMARY SHOULDER SURGERY ON (B)(6) 2024. ON (B)(6) 2024, THE PATIENT CAME IN REPORTING PAIN DUE TO A DISLOCATION OF THE LINER FROM THE GLENOSPHERE AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE METAPHYSIS AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY. ON (B)(6) 2025, THE PATIENT CAME IN REPORTING INSTABILITY AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE GLENOSPHERE, METAPHYSIS, AND LINER. THER SURGERY WAS COMPLETE SUCCESSFULLY.
Patient problems: Joint Laxity
MAUDE report 21771468 ↗InjuryMar 17, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AT ABOUT 1 YEAR AND 6 MONTHS AFTER PRIMARY, THE PATIENT CAME IN REPORTING STIFFNESS AND LIMITED MOBILITY AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE GLENOSPHERE, LINER AND METAPHYSIS. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Loss of Range of Motion
MAUDE report 21617414 ↗InjuryApr 8, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated
AT 3 YEARS AND 5 MONTHS FROM THE PRIMARY, THE PATIENT CAME IN REPORTING INSTABILITY AND THE CAUSE IS UNKNOWN. THE SURGEON UPSIZED THE GLENOSPHERE, LINER, AND METAPHYSIS. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Joint Dislocation
MAUDE report 19059643 ↗InjuryMar 23, 2023Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
AT ABOUT 1 MONTH AFTER THE PRIMARY SURGERY, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON REVISED THE COMPETITOR GLENOSPHERE AND MEDACTA METAPHYSIS AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Unspecified Infection
MAUDE report 16596968 ↗InjuryOct 19, 2021Unstable; Loosening of Implant Not Related to Bone-Ingrowth
THE PATIENT CAME IN REPORTING LATERAL INSTABILITY AND THE CAUSE OF THE INSTABILITY IS LAXITY. ABOUT 1 MONTH AND A HALF AFTER THE PRIMARY SURGERY, THE SURGEON REVISED THE GLENOSPHERE, LINER, AND METAPHYSIS. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Joint Laxity
MAUDE report 12655740 ↗InjuryDec 15, 2017Device Dislodged or Dislocated
REVISION SURGERY WAS NECESSARY DUE TO LUXATION.
Patient problems: Joint Dislocation
MAUDE report 7120560 ↗
Other Shoulder Prosthesis, Reverse Configuration devices
- DJO SURGICAL 508-36-101Encore Medical, L.P. · shoulder prosthesis, reverse configuration508 reports
- DJO SURGICAL 508-32-101Encore Medical, L.P. · shoulder prosthesis, reverse configuration433 reports
- DJO SURGICAL 508-32-103Encore Medical, L.P. · shoulder prosthesis, reverse configuration421 reports
- DJO SURGICAL 509-00-036Encore Medical, L.P. · shoulder prosthesis, reverse configuration1 recall259 reports
- DJO SURGICAL 508-32-104Encore Medical, L.P. · shoulder prosthesis, reverse configuration1 recall203 reports
- DJO SURGICAL 509-00-032Encore Medical, L.P. · shoulder prosthesis, reverse configuration233 reports
- DELTA XTEND 130760000Depuy (Ireland) · shoulder prosthesis, reverse configuration223 reports
- DJO SURGICAL 508-00-032Encore Medical, L.P. · shoulder prosthesis, reverse configuration122 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.