Shoulder System 04.01.0116Recalls & reported problems
Medacta International SA · Humeral Reverse HC Liner Ø32/+0mm · Class 2 · Implant
All models of Shoulder System (63)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 8
- Deaths reported
- 0
- Injuries reported
- 8
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 07630040706230), received between Dec 5, 2019 and Jul 10, 2026 — classified as 8 injuries.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem4
- Device Dislodged or Dislocated4
Patient problems
- Joint Laxity4
- Joint Dislocation3
- Pain1
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
InjuryJul 10, 2026Adverse Event Without Identified Device or Use Problem
THE PATIENT CAME IN PRESENTING INSTABILITY AND THE CAUSE IS UNKNOWN. THERE WAS NO INDICATION OF TRAUMA OR A FALL. ABOUT 1 YEAR AFTER THE PRIMARY SURGERY, THE SURGEON REVISED THE LAT. GLENOSPHERE 32XD 24.5 TO A LAT. GLENOSPHERE 39XD 24.5 AND REVISED THE REVERSE HC LINER D 32/+0MM TO A CONSTRAINED E-CROSS LINER D 39/+3 TO ADDRESS THE INSTABILITY. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Joint Laxity
MAUDE report 25778121 ↗InjuryJul 8, 2026Adverse Event Without Identified Device or Use Problem
REVISION SURGERY DUE TO JOINT LUXATION BETWEEN LINER AND COMPETITOR GLENOSPHERE AFTER ABOUT 1 YEAR AND 4 MONTHS FROM PRIMARY. THE SURGEON REVISED LINER AND METAPHYSIS.
Patient problems: Joint Dislocation
MAUDE report 25747737 ↗InjuryMar 31, 2026Device Dislodged or Dislocated
REVISION SURGERY DUE TO INSTABILITY ABOUT 8 MONTHS AFTER PRIMARY SURGERY AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED ALL MEDACTA IMPLANTS (METAPHYSIS, LINER, DIAPHYSIS, GLENOSPHERE, AND BASEPLATE) TO COMPETITOR IMPLANTS. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Joint Laxity
MAUDE report 24741263 ↗InjuryFeb 20, 2026Adverse Event Without Identified Device or Use Problem
AT ABOUT ONE MONTH AND A HALF FROM PRIMARY, THE PATIENT CAME IN PRESENTING INSTABILITY, AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE D 32 LINER TO A D 36+6 CONSTRAINED LINER, AND REVISED THE 32XD 24.5 GLENOSPHERE TO A 36XD 24.5 GLENOSPHERE. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Joint Laxity
MAUDE report 24399529 ↗InjuryMar 27, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated
ON THE (B)(6) 2025 THE PATIENT UNDERGONE REVERSE SHOULDER ARTHROPLASTY. ON THE (B)(6) 2025 THE PATIENT UNDERGONE REVISION SURGERY DUE TO JOINT LUXATION, LINER, DIAPHYSIS AND METAPHYSIS REVISED. ON THE (B)(6) 2025 THE PATIENT UNDERGONE A SECOND REVISION SURGERY DUE TO JOINT LUXATION, LINER, METAPHYSIS AND GLENOSPHERE REVISED.
Patient problems: Joint Dislocation
MAUDE report 21709024 ↗InjuryApr 26, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT CAME IN REPORTING PAIN AND INSTABILITY AND THE CAUSE IS UNKNOWN. ABOUT 2 YEARS AFTER THE PRIMARY SURGERY, THE SURGEON REVISED THE PATIENT BY CONVERTING THE REVERSE SHOULDER TO A HEMI-SHOULDER ARTHROPLASTY. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Joint Laxity
MAUDE report 16813631 ↗InjurySep 30, 2022Device Dislodged or Dislocated; Device Dislodged or Dislocated
AT ABOUT 1 MONTH AFTER THE PRIMARY SURGERY, THE PATIENT CAME IN THE EMERGENCY ROOM REPORTING PAIN DUE TO DISLOCATION AND THE CAUSE IS UNKNOWN. THE EMERGENCY ROOM DOCTOR REDUCED THE PATIENT AND PUT HER IN A SHOULDER SLING. WHEN THE PATIENT WENT TO A VISIT WITH THE OPERATING SURGEON, HE WAS PLANNING ON CEMENTING A NEW STEM, BUT AFTER OPENING THE PATIENT HE DECIDED THAT THE STEM WAS SOLID AND WAS NOT GOING TO SUBSIDE. THE SURGEON REVISED LINER FROM A +0 TO +6. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Pain
MAUDE report 15518430 ↗InjuryDec 5, 2019Device Dislodged or Dislocated
THE PATIENT CAME IN COMPLAINING OF PAIN DUE TO A SHOULDER DISLOCATION 1 MONTH AFTER PRIMARY. THE SURGEON REVISED THE LINER AND THE SURGERY WAS COMPLETED SUCCESSFULLY. NEW LINER: HUMERAL REVERSE HC LINER Ø32/+6MM.
Patient problems: Joint Dislocation
MAUDE report 9416218 ↗
Other Shoulder Prosthesis, Reverse Configuration devices
- DJO SURGICAL 508-36-101Encore Medical, L.P. · shoulder prosthesis, reverse configuration508 reports
- DJO SURGICAL 508-32-101Encore Medical, L.P. · shoulder prosthesis, reverse configuration433 reports
- DJO SURGICAL 508-32-103Encore Medical, L.P. · shoulder prosthesis, reverse configuration421 reports
- DJO SURGICAL 509-00-036Encore Medical, L.P. · shoulder prosthesis, reverse configuration1 recall259 reports
- DJO SURGICAL 508-32-104Encore Medical, L.P. · shoulder prosthesis, reverse configuration1 recall203 reports
- DJO SURGICAL 509-00-032Encore Medical, L.P. · shoulder prosthesis, reverse configuration233 reports
- DELTA XTEND 130760000Depuy (Ireland) · shoulder prosthesis, reverse configuration223 reports
- DJO SURGICAL 508-00-032Encore Medical, L.P. · shoulder prosthesis, reverse configuration122 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page