GMK Sphere Total Knee System 02.12.0310CRRRecalls & reported problems

Medacta International SA · GMK Sphere CR Tibial Insert #3R 10mm · Class 2 · Implant

All models of GMK Sphere Total Knee System (209)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
8
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 07630040707343), received between Aug 5, 2020 and Mar 10, 2026 — classified as 8 injuries.

The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem5
  • Appropriate Device Problem Term/Code Not Available2
  • Patient Device Interaction Problem1

Patient problems

  • Joint Laxity6
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Damage to Ligament(s)1
  • Discomfort1
  • Hypersensitivity/Allergic reaction1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 10, 2026Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY AT ABOUT 3 YEARS AND 2 MONTHS DUE TO PAIN AND INSTABILITY AS A RESULT OF A PCL TEAR. THERE WAS NO INDICATION OF TRAUMA OR A FALL. THE SURGEON REVISED THE PATIENT`S NATURAL PATELLA AND REVISED THE 10MM INSERT TO A 14MM INSERT. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Damage to Ligament(s); Joint Laxity

    MAUDE report 24558215 ↗
  • InjuryMay 12, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AT ABOUT 3 YEARS AFTER THE PRIMARY, THE PATIENT CAME IN REPORTING LATERAL INSTABILITY AND THE CAUSE OF THE INSTABILITY IS UNKNOWN. THE SURGEON REVISED THE LINER (10 TO 12 MM) FOR STABILITY. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Laxity

    MAUDE report 22000386 ↗
  • InjuryDec 30, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AT ABOUT 2 YEARS AND 3 MONTHS FROM THE PRIMARY, THE PATIENT CAME IN REPORTING INSTABILITY AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE LINER (FROM 10 TO 14 MM) AND THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Laxity

    MAUDE report 21033590 ↗
  • InjuryAug 22, 2024Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    THE PATIENT CAME IN REPORTING INSTABILITY AND HAD A BONE SCAN PERFORMED, WHICH INDICATED POSSIBLE LOOSENING OF THE TIBIAL TRAY. AT ABOUT 2 YEARS AND 11 MONTHS POST PRIMARY THE SURGEON OPENED THE KNEE AND FOUND THAT THE TIBIAL TRAY WAS WELL FIXED. THE SURGEON PERFORMED A POLY SWAP (SAME REF BUT E-CROSS) AND THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 20026724 ↗
  • InjuryJun 25, 2024Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    THE PATIENT CAME IN REPORTING INSTABILITY AND THE CAUSE IS UNKNOWN. ABOUT 4 YEARS AND 1 MONTH AFTER THE PRIMARY SURGERY, THE SURGEON REVISED THE INSERT (FROM 10 TO 14 MM) AND THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Laxity

    MAUDE report 19605536 ↗
  • InjuryMay 10, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AT ABOUT 3 YEARS 7 MONTHS AFTER THE PRIMARY, THE PATIENT CAME IN REPORTING INSTABILITY AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE INSERT (10MM TO 12 MM) AND THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Laxity

    MAUDE report 16900771 ↗
  • InjuryOct 14, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AT ABOUT 3 YEARS AFTER THE PRIMARY, THE PATIENT CAME IN REPORTING KNEE INSTABILITY. AFTER AN EXAMINATION, THE SURGEON SPOKE ABOUT THE BENEFITS OF THE MORE CONSTRAINED MEDIAL BALL IN SOCKET (E CROSS FLEX) LINER. THE PATIENT AGREED TO DO A LINER EXCHANGE (FIXED CR 10 MM TO E-CROSS FLEX 13 MM) AND THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Laxity

    MAUDE report 15604928 ↗
  • InjuryAug 5, 2020Patient Device Interaction Problem; Patient Device Interaction Problem

    THE PATIENT CAME IN REPORTING DISCOMFORT DUE TO DEVELOPING AN ALLERGIC REACTION. THE SURGEON REMOVED ALL COMPONENTS AND REPLACE THEM WITH OXINIUM COMPETITOR IMPLANTS. THE SURGERY WAS COMPLETED SUCCESSFULLY 11 MONTHS AFTER PRIMARY.

    Patient problems: Discomfort; Hypersensitivity/Allergic reaction

    MAUDE report 10366325 ↗

Other Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices

All Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices →