AMIStem-P 01.18.401Recalls & reported problems
Medacta International SA · AMIStem-P Std. #1 · Class 2 · Implant
All models of AMIStem-P (18)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 11
- Deaths reported
- 0
- Injuries reported
- 11
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 07630040720007), received between May 22, 2019 and Dec 24, 2025 — classified as 11 injuries.
The most frequently reported specific device problem is “Osseointegration Problem” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem3
- Osseointegration Problem3
- Appropriate Device Problem Term/Code Not Available2
- Fracture2
- Loosening of Implant Not Related to Bone-Ingrowth1
- Migration or Expulsion of Device1
Patient problems
- Bone Fracture(s)4
- Pain3
- Implant Pain1
- Inadequate Osseointegration1
- Insufficient Information1
- Unspecified Infection1
Recent adverse event reports
The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.
InjuryDec 24, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AT ABOUT 1 MONTH FROM PRIMARY, THE PATIENT CAME IN PRESENTING PAIN THAT WAS THE RESULT OF A PERIPROSTHETIC FRACTURE. THE SURGEON CABLED THE FRACTURE, AND REVISED THE STEM TO A M-VIZION STEM AND THE HEAD TO AN IDENTICAL ONE. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Bone Fracture(s)
MAUDE report 23886577 ↗InjuryJun 19, 2024Osseointegration Problem; Osseointegration Problem
HIP REVISION DUE TO STEM LOOSENING. THE HEAD AND STEM HAVE BEEN REVISED SUCCESSFULLY. PRIMARY SURGERY DATE IS UNKNOWN.
Patient problems: Implant Pain
MAUDE report 19566893 ↗InjuryJul 31, 2023Osseointegration Problem; Osseointegration Problem
AT ABOUT 2 WEEKS FROM THE PRIMARY, THE PATIENT CAME IN REPORTING PAIN DUE TO A LOOSE STEM AND THE CAUSE OF THE LOOSE STEM IS UNKNOWN. THE SURGEON REVISED THE STEM, HEAD, AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Inadequate Osseointegration
MAUDE report 17424478 ↗InjuryJan 19, 2023Osseointegration Problem; Osseointegration Problem
AT ABOUT 3 MONTHS AFTER THE PRIMARY, THE PATIENT CAME IN REPORTING PAIN DUE TO A LOOSE STEM AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE STEM AND HEAD AND THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Pain
MAUDE report 16204987 ↗InjuryJun 9, 2022Loosening of Implant Not Related to Bone-Ingrowth
THE PATIENT CAME IN REPORTING PAIN DUE TO ASEPTIC LOOSENING OF THE STEM AND THE CAUSE IS UNKNOWN. AT 3 YEARS AND 5 MONTHS FROM PRIMARY THE SURGEON REVISED THE MEDACTA STEM AND HEAD WITH COMPETITOR COMPONENTS AND REVISED THE MEDACTA LINER WITH A MEDACTA LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Pain
MAUDE report 14643331 ↗InjuryNov 17, 2021Appropriate Device Problem Term/Code Not Available
AT 4 MONTHS AFTER PRIMARY THA, REVISION SURGERY FOR STEM SUBSIDENCE. THE REASON OF THE SUBSIDENCE IS UNKNOWN. STEM AND HEAD REVISED SUCCESSFULLY.
Patient problems: Insufficient Information
MAUDE report 12826689 ↗InjuryApr 16, 2021Adverse Event Without Identified Device or Use Problem
THE PATIENT CAME IN 1 MONTH AFTER THE PRIMARY REPORTING PAIN DUE TO FALLING. THE SURGEON OBSERVED REDNESS AND SWELLING AT THE INCISION SITE AND DECIDED TO PERFORM A WASHOUT AND REVISE THE HEAD AND LINER. 1 DAY AFTER THE REVISION THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON REMOVED ALL COMPONENTS AND IMPLANTED AN ANTIBIOTIC SPACER. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Unspecified Infection
MAUDE report 11676929 ↗InjuryFeb 18, 2021Fracture; Appropriate Device Problem Term/Code Not Available
THE PATIENT CAME IN REPORTING PAIN DUE TO A PERIPROSTHETIC FRACTURE 3 MONTHS AFTER THE PRIMARY. THE CAUSE OF THE PERIPROSTHETIC FRACTURE IS UNKNOWN. THE SURGEON CABLED THE FRACTURE, REVISED THE STEM AND HEAD WITH COMPETITOR PRODUCTS, AND REVISED THE MEDACTA LINER WITH A MEDACTA LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Bone Fracture(s)
MAUDE report 11341873 ↗InjuryDec 29, 2020Migration or Expulsion of Device
THE PATIENT CAME IN REPORTING PAIN DUE TO A SUBSIDED STEM, 1 YEAR 4 MONTHS AFTER THE PRIMARY. THE CAUSE OF THE SUBSIDED STEM IS UNKNOWN. THE SURGEON REVISED THE AMISTEM-P STD. #1 WITH A SMS SOLID STEM STD #10 AND REVISED THE 32MM BIOLOX DELTA HEAD S WITH A 32MM BIOLOX DELTA HEAD S.
Patient problems: Pain
MAUDE report 11086056 ↗InjuryMar 4, 2020Fracture
THE PATIENT CAME IN REPORTING PAIN DUE TO A BONE FRACTURE AFTER 1 MONTH AND HALF FROM THE PRIMARY. THE SURGEON CABLED THE FRACTURE AND REVISED THE STEM, HEAD, AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Bone Fracture(s)
MAUDE report 9785156 ↗InjuryMay 22, 2019Adverse Event Without Identified Device or Use Problem
DURING THE PRIMARY HIP SURGERY AND UPON THE SURGEON IMPLANTING THE STEM, THE PATIENT SUSTAINED A PERI-PROSTHETIC FRACTURE OF THE FEMUR, PRIMARY SURGERY WAS PERFORMED USING POSTERIOR APPROACH. THE SURGEON CABLED THE FRACTURE. THE SURGERY WAS COMPLETED SUCCESSFULLY WITH A FEW DELAY OF 4 MINUTES. THE PATIENT WAS OBESE AND SMOKER.
Patient problems: Bone Fracture(s)
MAUDE report 8631625 ↗
Other Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented devices
- PINNACLE 1217-25-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED735 reports
- NA 1365-52-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED683 reports
- APEX 1246-03-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED3 deaths613 reports
- PINNACLE 1217-20-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED2 deaths590 reports
- PINNACLE 1217-30-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED1 death484 reports
- NA 1365-53-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED404 reports
- PINNACLE ALTRX 1221-36-054Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED388 reports
- PINNACLE ALTRX 1221-32-050Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED386 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page