M-Vizion Femoral Revision System 01.22.165Recalls & reported problems
Medacta International SA · Distal Stem Ø16mm L 220mm straight · Class 2 · Implant
All models of M-Vizion Femoral Revision System (30)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07630040729116), received between Nov 20, 2024 and Nov 20, 2024 — classified as 1 injury.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device Dislodged or Dislocated1
- Migration1
Patient problems
- Implant Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryNov 20, 2024Device Dislodged or Dislocated; Migration; Device Dislodged or Dislocated; Migration
THE PATIENT HAD A PRIMARY SURGERY WITH A COMPETITOR ON AN UNKNOWN DATE. SUBSEQUENTLY, ON THE (B)(6) 2024, THE COMPETITOR STEM AND HEAD WERE REVISED TO MEDACTA IMPLANTS. PRESENTLY, ON (B)(6) 2024, THE PATIENT CAME IN REPORTING PAIN AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE MEDACTA STEM AND HEAD WITH COMPETITOR IMPLANTS. SURGERY WAS COMPLETED SUCCESSFULLY. NO ISSUES DETECTED WITH IMPLANTS, ONLY PAIN WAS REPORTED. IT IS UNKNOWN WHETHER OR NOT THE COMPETITOR LINER WAS REVISED, BUT A MEDACTA LINER WAS NOT USED IN ANY SURGERY. THE DISTRICT SALES MANAGER DIDN'T HAVE ANY REPS IN THIS HOSPITAL AREA SO NO OTHER INFORMATION IS AVAILABLE. FROM THE ANALYSIS OF THE X-RAYS, IT IS VISIBLE THAT JOINT LUXATION OCCURRED. MOREOVER, THE FEMUR SHAPE APPEARS IRREGULAR, WITH CERCLAGE WIRES AND THE STEM LIKELY SHOWS SIGNS OF SUBSIDENCE, PROBABLY A RESULT OF NON-ADEQUATE PRIMARY STABILITY.
Patient problems: Implant Pain
MAUDE report 20734636 ↗
Other Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented devices
- BIOLOX DELTA 1365-32-310Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented551 reports
- PINNACLE ALTRX 1221-36-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented481 reports
- BIOLOX DELTA 1365-32-320Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death314 reports
- BIOLOX DELTA 1365-36-720Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death189 reports
- DJO SURGICAL 400-03-362Encore Medical, L.P. · Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented187 reports
- Anthology 71365705Smith & Nephew, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented176 reports
- BIOLOX DELTA 1365-40-710Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented170 reports
- PINNACLE GRIPTION 1217-32-054Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented169 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page