Mpact Acetabular System 01.32.3644HC10ARecalls & reported problems

Medacta International SA · Face-changing 10° PE HC liner Ø36/E · Class 2 · Implant

All models of Mpact Acetabular System (68)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
7
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 07630040731034), received between Jan 21, 2021 and Sep 5, 2025 — classified as 7 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (7 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Dislodged or Dislocated7
  • Appropriate Device Problem Term/Code Not Available1

Patient problems

  • Implant Pain4
  • Joint Dislocation2
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • InjurySep 5, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THE PATIENT HAD A PRIMARY HIP SURGERY ON (B)(6) 2025. ON (B)(6) 2025, THE PATIENT CAME IN REPORTING PAIN DUE TO A DISLOCATION OF THE HEAD FROM THE LINER, AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY. (MDR 2025-00769) ON (B)(6) 2025, THE PATIENT CAME IN REPORTING PAIN DUE TO A DISLOCATION OF THE HEAD FROM THE LINER, AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE MEDACTA HEAD AND LINER TO COMPETITOR COMPONENTS. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Dislocation

    MAUDE report 22977014 ↗
  • InjuryMar 19, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THE PATIENT HAD A PRIMARY HIP SURGERY ON (B)(6) 2021. ON (B)(6) 2021, THE PATIENT CAME IN REPORTING PAIN DUE TO A DISLOCATION OF THE HEAD FROM THE LINER. THE CAUSE OF THE DISLOCATION IS UNKNOWN. THE SURGEON REVISED THE HEAD AND LINER AND THE SURGERY WAS COMPLETED SUCCESSFULLY. PRESENTLY, ON (B)(6) 2025, THE PATIENT CAME IN REPORTING PAIN DUE TO A DISLOCATION OF THE HEAD FROM THE LINER AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE MEDACTA CUP AND LINER TO COMPETITOR COMPONENTS AND REVISED THE MEDACTA HEAD WITH A MEDACTA HEAD. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Implant Pain

    MAUDE report 21642678 ↗
  • InjuryJan 14, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated

    REVISION SURGERY DUE TO A DISLOCATION OF THE HEAD OF THE COMPETITOR FROM THE MEDACTA LINER. AT ABOUT 3 WEEKS FROM PRIMARY, THE SURGEON REVISED THE CUP AND LINER AND THE SURGERY WAS COMPLETED SUCCESSFULLY. A DIRECT ANTERIOR APPROACH WAS UTILIZED IN THE PRIMARY SURGERY.

    Patient problems: Implant Pain

    MAUDE report 21146977 ↗
  • InjuryOct 3, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    AT 4 MONTHS FROM THE PRIMARY, THE PATIENT CAME IN REPORTING PAIN, DUE TO A DISLOCATION OF THE COMPETITOR HEAD FROM THE MEDACTA LINER, AND THE CAUSE OF THE DISLOCATION IS UNKNOWN. THE SURGEON REVISED MEDACTA FLAT LINER WITH A MEDACTA FACE CHANGING LINER AND THE SURGERY WAS COMPLETED SUCCESSFULLY. A DIRECT ANTERIOR APPROACH WAS UTILIZED IN THE PRIMARY SURGERY.

    Patient problems: Implant Pain

    MAUDE report 20359324 ↗
  • InjuryApr 4, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THE PATIENT HAD A PRIMARY HIP SURGERY ON (B)(6) 2018. ON (B)(6) 2023, THE PATIENT CAME IN REPORTING PAIN DUE TO A DISLOCATION OF THE HEAD FROM THE LINER THAT WAS CAUSED FROM FALLING. THE SURGEON REVISED THE HEAD AND LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY. PRESENTLY, ON (B)(6) 2024, THE PATIENT CAME IN REPORTING PAIN DUE TO A DISLOCATION OF THE HEAD FROM THE LINER AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE CUP, LINER, SCREWS AND HEAD. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Implant Pain

    MAUDE report 19039614 ↗
  • InjuryJul 25, 2023Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THE PATIENT HAD A PRIMARY HIP SURGERY ON (B)(6)2023. IMMEDIATELY AFTER THE PRIMARY SURGERY, IN POST-OP RECOVERY ON (B)(6)2023, THE PATIENT'S HEAD DISLOCATED FROM THE LINER. THE SURGEON REVISED THE LINER AND THE SURGERY WAS COMPLETED SUCCESSFULLY. PRESENTLY, ON (B)(6)2023, THE PATIENT CAME IN REPORTING PAIN DUE TO A DISLOCATION OF THE HEAD FROM THE LINER. THE SURGEON REVISED THE MEDACTA CUP AND LINER WITH COMPETITOR COMPONENTS AND REVISED THE MEDACTA HEAD WITH A MEDACTA HEAD. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17389616 ↗
  • InjuryJan 21, 2021Device Dislodged or Dislocated; Appropriate Device Problem Term/Code Not Available

    4 MONTHS AFTER THE PREVIOUS REVISION SURGERY THE PATIENT CAME IN REPORTING PAIN DUE TO A DISLOCATION OF THE HEAD FROM THE LINER. THE SURGEON REVISED THE BIOLOX HEAD AND SLEEVE, AND FACE CHANGING LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY. THE FIRST REVISION SURGERY WAS PERFORMED ALSO DUE TO DISLOCATION (HEAD AND LINER REVISED).

    Patient problems: Joint Dislocation

    MAUDE report 11207698 ↗

Other Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented devices

All Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented devices →