GMK Total Knee System 02.12.KA13LRecalls & reported problems

Medacta International SA · Femoral Component SPHERIKA Cemented S3+L · Class 2 · Implant

All models of GMK Total Knee System (31)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 07630345716217), received between Feb 22, 2023 and May 12, 2026 — classified as 6 injuries.

The most frequently reported specific device problem is “Device Appears to Trigger Rejection” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Appears to Trigger Rejection2
  • Adverse Event Without Identified Device or Use Problem1
  • Appropriate Device Problem Term/Code Not Available1
  • Loosening of Implant Not Related to Bone-Ingrowth1
  • Malposition of Device1

Patient problems

  • Joint Laxity2
  • Hypersensitivity/Allergic reaction1
  • Implant Pain1
  • Medical device site infection1
  • Unspecified Infection1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 12, 2026Device Appears to Trigger Rejection

    AT ABOUT 5 MONTHS FROM THE PRIMARY, THE PATIENT CAME IN DUE TO SIGNS OF INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE GMK-SPHERIKA FEMORAL COMPONENT, INSERT, AND TIBIAL TRAY TO A GMK-HINGE SYSTEM. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 25148962 ↗
  • InjuryJan 13, 2026Loosening of Implant Not Related to Bone-Ingrowth

    THE PATIENT HAD KNEE INSTABILITY DUE TO LOOSE IMPLANTS AND THE CAUSE IS UNKNOWN. THE SURGEON SUSPECTED A NICKEL ALLERGY AND AT ABOUT 1 YEAR AND 10 MONTHS POST PRIMARY REVISED THE TIBIAL TRAY AND FEMORAL COMPONENT TO SENSITIN REVISION COMPONENTS. THE SURGEON ALSO REVISED THE INSERT FROM A 10MM TO A 12MM. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Hypersensitivity/Allergic reaction

    MAUDE report 24051152 ↗
  • InjurySep 9, 2024Malposition of Device; Malposition of Device

    PRIMARY KNEE SURGERY PERFORMED ON (B)(6) 2024. X-RAYS TAKEN IMMEDIATELY POST-OP SHOWED THAT THE NEUTRAL ALIGNMENT WAS 187° WITH 13° OF VALGUS ON A FULL LEG. NO ISSUE HAS BEEN FOUND DURING SURGERY WITH NEXTAR. FOR THE MOMENT (B)(6) 2024) THE PATIENT IS DOING WELL AND NO REVISION IS PLANNED.

    Patient problems: Implant Pain

    MAUDE report 20167519 ↗
  • InjuryAug 23, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AT ABOUT 2 MONTHS AFTER PRIMARY, THE PATIENT CAME IN REPORTING INSTABILITY AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED ALL COMPONENTS TO GMK-HINGE COMPONENTS AND THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Laxity

    MAUDE report 20046119 ↗
  • InjuryJan 17, 2024Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    A DAY AFTER THE PRIMARY KNEE SURGERY, THE PATIENT REPORTED INSTABILITY AND THE CAUSE IS UNKNOWN. THE SURGEON DECIDED TO REVISE THE PATIENT TO GMK-HINGE COMPONENTS. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Laxity

    MAUDE report 18524338 ↗
  • InjuryFeb 22, 2023Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    AT ABOUT 3 MONTHS AFTER THE PRIMARY, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT IMPLANTED AN ANTIBIOTIC SPACER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Unspecified Infection

    MAUDE report 16417238 ↗

Other Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices

All Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices →