GMK Sphere Total Knee System 02.12.E0314FLRecalls & reported problems

Medacta International SA · Tibial Insert Fixed SPHERE FLEX #3/14 mm L E-Cross · Class 2 · Implant

All models of GMK Sphere Total Knee System (209)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 07630971261679), received between Sep 10, 2024 and Aug 3, 2026 — classified as 6 injuries.

The most frequently reported specific device problem is “Device Appears to Trigger Rejection” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Device Appears to Trigger Rejection2
  • Device Dislodged or Dislocated1

Patient problems

  • Joint Laxity3
  • Medical device site infection3
  • Joint Dislocation1
  • Pain1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 3, 2026Device Appears to Trigger Rejection

    The patient had a primary knee surgery on (b)(6) 2019. On (b)(6) 2025, the patient had instability and a & quot; clicking & quot; noise in knee and the cause is unknown. There was no reports of trauma. The surgeon revised the Flex S3L - 10mm insert to a Flex 3L - 14mm insert. The surgery was completed successfully "[MDR 2026-00469]". On (b)(6) 2026, the patient had signs of an infection and the cause is unknown. The surgeon performed a washout and revised the GMK-SPHERE tibial insert E-Cross - Flex 3L - 14mm with a new GMK-SPHERE tibial insert E-Cross - Flex 3L - 14mm. The surgery was completed successfully.

    Patient problems: Medical device site infection

    MAUDE report 50114127 ↗
  • InjuryApr 30, 2026Adverse Event Without Identified Device or Use Problem

    THE PATIENT CAME IN PRESENTING INSTABILITY, THE REASON IS UNKNOWN. AT ABOUT 1 YEAR AND 3 MONTHS POST PRIMARY THE SURGEON PERFORMED A WASHOUT AND REVISED THE 14MM INSERT TO A 17MM INSERT, REVISED THE GMK-SPHERIKA S3 FEMORAL COMPONENT TO A GMK-REVISION S4 FEMORAL COMPONENT, AND REVISED THE PRIMAY L30MM EXTENSION STEM WITH A FLUTED L150MM EXTENSION STEM.

    Patient problems: Joint Laxity

    MAUDE report 25040713 ↗
  • InjuryDec 18, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AT 2 WEEKS FROM THE PRIMARY, THE PATIENT CAME IN DUE TO AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 23838610 ↗
  • InjuryNov 18, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    AT ABOUT 1 YEAR 1 MONTH FROM THE PRIMARY, THE PATIENT CAME IN DUE TO AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND POLY SWAP. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 23579655 ↗
  • InjuryJul 17, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated

    AT ABOUT 3 MONTHS FROM PRIMARY, THE PATIENT CAME IN REPORTING INSTABILITY DUE TO LATERAL DISLOCATION. THE SURGEON REVISED TO A THICKER POLY, 14MM TO 20MM, AND USED SUTURES TO TIGHTEN THE LCL. THE SURGERY WAS COMPLETED SUCCESSFULLY

    Patient problems: Joint Dislocation; Joint Laxity

    MAUDE report 22529149 ↗
  • InjurySep 10, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AT 5 MONTHS FROM THE PRIMARY, THE PATIENT CAME IN REPORTING INSTABILITY AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE LINER (FROM 14 TO 20 MM). THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Laxity; Pain

    MAUDE report 20180516 ↗

Other Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices

All Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices →