GMK Sphere Total Knee System 02.12.E0314FRRecalls & reported problems
Medacta International SA · Tibial Insert Fixed SPHERE FLEX #3/14 mm R E-Cross · Class 2 · Implant
All models of GMK Sphere Total Knee System (209)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 5
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 07630971261686), received between Aug 26, 2024 and Mar 30, 2026 — classified as 5 injuries, 1 malfunction.
The most frequently reported specific device problem is “Device Appears to Trigger Rejection” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem5
- Device Appears to Trigger Rejection1
Patient problems
- Joint Laxity4
- Implant Pain2
- Damage to Ligament(s)1
- Loss of Range of Motion1
- Medical device site infection1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
InjuryMar 30, 2026Adverse Event Without Identified Device or Use Problem
REVISION SURGERY DUE TO KNEE INSTABILITY ABOUT 1 YEAR AND 5 MONTHS AFTER PRIMARY SURGERY AND THE CAUSE IS UNKNOWN. THERE WAS NO TRAUMA REPORTED. THE SURGEON UPSIZED THE 14MM INSERT TO A 17MM INSERT TO ADDRESS THE INSTABILITY. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Implant Pain; Joint Laxity
MAUDE report 24711041 ↗InjuryFeb 18, 2026Adverse Event Without Identified Device or Use Problem
AT ABOUT 9 MONTHS FROM THE PRIMARY, THE PATIENT CAME IN PRESENTING PAIN AS THE RESULT OF A PATELLA TENDON RUPTURE AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE INSERT FROM A 14MM TO A 17MM DUE TO INSTABILITY. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Damage to Ligament(s); Joint Laxity
MAUDE report 24376299 ↗MalfunctionNov 18, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AT ABOUT 1 YEAR FROM THE PRIMARY, THE PATIENT CAME IN REPORTING INSTABILITY AND THE CAUSE IS UNKNOWN. THE SURGEON WOULD LIKE TO UPSIZE THE POLY (FROM 14 MM TO 15 OR 16 MM) TO GIVE THE PATIENT MORE STABILITY. A COMPASSIONATE USE CASE IS BEING INITIATED TO REQUEST THESE CUSTOM SIZE INSERTS FOR THE PATIENT. A SURGERY HAS NOT BEEN SCHEDULED AT THIS TIME. MORE DETAILS TO FOLLOW ONCE THE SURGERY IS COMPLETE.
Patient problems: Implant Pain; Joint Laxity
MAUDE report 23583091 ↗InjuryMay 21, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AT ABOUT 1 YEAR 1 MONTH AFTER THE PRIMARY, THE PATIENT REPORTED SOME INSTABILITY IN R KNEE. THE SURGEON MADE DECISION TO UPSIZE THE POLY TO ACHIEVE GREATER STABILITY (14 TO 20 MM).
Patient problems: Joint Laxity
MAUDE report 22060082 ↗InjuryMar 19, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AT ABOUT 6 MONTHS AFTER PRIMARY, THE PATIENT CAME IN REPORTING PAIN AND STIFFNESS AND THE CAUSE IS UNKNOWN. THE SURGEON REVISED THE LINER (14MM) WITH A THINNER ONE (10MM) AND THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Loss of Range of Motion
MAUDE report 21642960 ↗InjuryAug 26, 2024Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
AT ABOUT 3 MONTHS AFTER PRIMARY, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Medical device site infection
MAUDE report 20062378 ↗
Other Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices
- ATTUNE 1506-00-005Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER589 reports
- ATTUNE 1506-00-004Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER580 reports
- JOURNEY 74012812Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER502 reports
- JOURNEY 74011856Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER438 reports
- PERSONA™ 42-5099-094-00Zimmer, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER406 reports
- JOURNEY 74011857Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER388 reports
- ATTUNE 1506-00-007Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER288 reports
- ATTUNE 1506-00-003Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page