M-Vizion Femoral Revision System 01.22.408Recalls & reported problems

Medacta International SA · Proximal Body Ø20mm L 50mm LAT with holes · Class 2 · Implant

All models of M-Vizion Femoral Revision System (30)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 07630971263574), received between Mar 27, 2025 and Jul 31, 2025 — classified as 3 injuries.

The most frequently reported specific device problem is “Device Appears to Trigger Rejection” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 2 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Appears to Trigger Rejection1
  • Inadequacy of Device Shape and/or Size1
  • Positioning Problem1

Patient problems

  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Medical device site infection1
  • Pain1
  • Unequal Limb Length1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 31, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection

    AT ABOUT 2 YEARS AND 10 MONTHS FROM PRIMARY SURGERY, THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION, AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT, REMOVED ALL IMPLANTS, AND IMPLANTED AN ANTIBIOTIC SPACER. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Medical device site infection

    MAUDE report 22674986 ↗
  • InjuryJul 29, 2025Positioning Problem; Positioning Problem

    AT ABOUT 1 WEEK FROM PRIMARY THE PATIENT UNDERWENT REVISION SURGERY DUE TO A MALPOSITIONING OF THE DISTAL STEM (FALSA VIA). THE ENTIRE CONSTRUCT HAS BEEN REVISED. THE TWO PARTS COULD NOT BE SEPARATED AS THE TIP OF THE SCREWDRIVER USING DURING PRIMARY BROKE INSIDE THE LOCKING SCREW. DURING THE TIGHTENING OF THE LOCKING SCREW THE SCREW DRIVER TIP BROKE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 22643026 ↗
  • InjuryMar 27, 2025Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size

    M-VIZION STEM WAS IMPLANTED ON (B)(6) 2025. THE PATIENT NEEDED TO BE REVISED BECAUSE WAS EXPERIENCING PAIN, INSTABILITY AND LEG LENGTH DISCREPANCY, DUE TO A TOO SHORT PROXIMAL BODY IMPLANTED AT THE PRIMARY SURGERY. THE REVISION SURGERY TOOK PLACE 1 MONTH AFTER THE PRIMARY SURGERY AND THE PLAN WAS TO REVISE ONLY THE PROXIMAL BODY. HOWEVER, THE DISASSEMBLY ROD BENT DURING PROXIMAL STEM EXTRACTION FROM THE DISTAL BODY. DESPITE THE ATTEMPTS, THE PROXIMAL BODY COULD NOT BE REMOVED FROM THE DISTAL STEM, THEREFORE THE SURGEON DECIDED TO REMOVE THE ENTIRE STEM (PROXIMAL + DISTAL). THE REVISION SURGERY WAS ALSO TREATED WITH AN M-VIZION. HERE, THE SURGEON CHOSE A 16MM 180MM DISTAL STEM WITH A LONGER PROXIMAL BODY 20MM 70MM TO COMPENSATE FOR THE INSTABILITY.

    Patient problems: Pain; Unequal Limb Length

    MAUDE report 21708063 ↗

Other Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented devices

All Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented devices →