M-Vizion Femoral Revision System 01.22.410Recalls & reported problems
Medacta International SA · Proximal Body Ø20mm L 70mm LAT with holes · Class 2 · Implant
All models of M-Vizion Femoral Revision System (30)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07630971263598), received between Feb 24, 2026 and Feb 24, 2026 — classified as 1 malfunction.
The most frequently reported specific device problem is “Mechanical Jam” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Mechanical Jam1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 24, 2026Mechanical Jam
DURING THE ATTEMPTS OF REMOVAL OF THE PROXIMAL BODY FROM THE DISTAL STEM, THE PROXIMAL BODY HANDLE DEFORMED AND IT WAS NOT POSSIBLE TO DISCONNECT THE PROXIMAL BODY FROM THE DISTAL STEM. THE SURGEON LEFT THE CONSTRUCT IN PLACE WITH NO LOCKING SCREW AND PROCEEDED CHANGING ONLY THE HEAD. THIS EVENT HAPPENED DURING A REVISION SURGERY PERFORMED ABOUT 6 MONTHS AFTER THE PRIMARY SURGERY DUE TO INSTABILITY AND DISLOCATION. THE SURGEON WANTED TO CORRECT THE ROTATION OF THE PROXIMAL BODY AND TO IMPLANT A PROXIMAL BODY 10MM LONGER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24429841 ↗
Other Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented devices
- BIOLOX DELTA 1365-32-310Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented551 reports
- PINNACLE ALTRX 1221-36-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented481 reports
- BIOLOX DELTA 1365-32-320Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death314 reports
- BIOLOX DELTA 1365-36-720Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death189 reports
- DJO SURGICAL 400-03-362Encore Medical, L.P. · Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented187 reports
- Anthology 71365705Smith & Nephew, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented176 reports
- BIOLOX DELTA 1365-40-710Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented170 reports
- PINNACLE GRIPTION 1217-32-054Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented169 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page