Passeo-35 8/40/80Recalls & reported problems
Biotronik AG · Class 2
All models of Passeo-35 (24)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07640119558202), received between Feb 7, 2022 and Dec 11, 2024 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fluid/Blood Leak1
- Material Rupture1
Patient problems
- Insufficient Information1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 11, 2024Material Rupture; Material Rupture
THE PASSEO-35 BALLOON RUPTURED DURING THE INTERVENTION. UPON REMOVAL, PART OF THE BALLOON WAS LOST. FURTHER INFORMATION IS REQUESTED.
Patient problems: Insufficient Information
MAUDE report 20906635 ↗MalfunctionFeb 7, 2022Fluid/Blood Leak; Fluid/Blood Leak
A PASSEO-35 BALLOON CATHETER WAS SELECTED FOR TREATMENT OF AN ANEURYSM IN THE OSTIAL SUBCLAVIAN ARTERY. THE DEVICE WAS ADVANCE OVER THE WIRE AND INFLATED AT SUBCLAVIAN ARTERY TO POST DILATE A COVERED STENT. 11 BAR PRESSURE WAS APPLIED. THE BALLOON COULD NOT INFLATE FURTHER AND LEAKING OF CONTRAST WAS OBSERVED IN THE FLUOROSCOPY. BLOOD ALSO OBSERVED IN THE SYRINGE OF THE INFLATION DEVICE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13471102 ↗
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page