Skip to content

Pantera Pro 2.00/20/140Recalls & reported problems

Biotronik AG · Class 2

All models of Pantera Pro (13)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07640130437111), received between Oct 27, 2020 and Oct 27, 2020 — classified as 1 malfunction.

The most frequently reported specific device problem is “Material Deformation” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Material Deformation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 27, 2020Material Deformation; Material Deformation

    THE PANTERA PRO BALLOON CATHETER WAS CHOSEN FOR THE TREATMENT. DURING PREPARATION IT WAS NOT POSSIBLE TO INSERT THE GUIDEWIRE INTO THE GUIDEWIRE LUMEN OF THE PANTERA PRO AND THE TIP OF THE BALLOON CATHETER SEEMED TO BE DAMAGED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10740550 ↗

Other Catheters, transluminal coronary angioplasty, percutaneous devices

All Catheters, transluminal coronary angioplasty, percutaneous devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page