Skip to content

Pulsar-18 T3 6/200/135Recalls & reported problems

Biotronik AG · Class 3 · Implant

All models of Pulsar-18 T3 (52)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 07640130447042), received between Jul 16, 2021 and Dec 15, 2025 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Failure to Advance” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Advance2
  • Material Deformation2
  • Activation Failure1
  • Malposition of Device1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 15, 2025Failure to Advance; Failure to Advance

    THE PULSAR-18 T3 PERIPHERAL SELF-EXPANDABLE STENT SYSTEM WAS SELECTED FOR TREATMENT OF A MODERATELY CALCIFIED LESION (80% STENOSIS DEGREE) IN A MILDLY TORTUOUS PART OF THE PROXIMAL FEMORAL ARTERY. AFTER PRE-DILATATION, THE PULSAR-18 T3 STENT SYSTEM COULD NOT PASS THE LESION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23800884 ↗
  • MalfunctionMar 3, 2025Failure to Advance; Failure to Advance

    THE PULSAR-18 T3 PERIPHERAL SELF-EXPANDABLE STENT SYSTEM WAS SELECTED FOR TREATMENT OF A MODERATELY CALCIFIED LESION (75 PERCENT STENOSIS DEGREE) IN A MODERATELY TORTUOUS PART OF THE MID SFA. DESPITE PRE-DILATATION, THE LESION COULD NOT BE CROSSED WITH THE DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21510753 ↗
  • MalfunctionDec 11, 2024Malposition of Device; Material Deformation; Activation Failure; Malposition of Device; Material Deformation; Activation Failure

    A PULSAR-18 T3 SELF-EXPANDABLE STENT SYSTEM WAS SELECTED FOR TREATMENT FOR A SEVERELY CALCIFIED LESION IN THE SFA. AT THE MOMENT OF THE DEPLOYMENT, AFTER HAVING PULLED BACK THE STENT BECAUSE OF MINOR PHYSIOLOGICAL JUMPING OF THE DEVICE WHEN RELEASING THE FIRST STRUTS, THE SHAFT STARTED MOVING DISTALLY, ENDING UP WITH COMPRESSION OF THE STENT AND PROXIMAL MISALIGNMENT/SHORTENING. THIS 6X200MM STENT WAS FINALLY DEPLOYED AT A LENGTH OF ROUGHLY 170MM. AN ADDITIONAL PULSAR 6X60MM WAS DEPLOYED PROXIMALLY TO COVER THE PROXIMAL DISEASED PART LEFT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20903454 ↗
  • MalfunctionJul 16, 2021Material Deformation; Material Deformation

    A PULSAR-18 T3 6/200/135 PERIPHERAL STENT SYSTEM WAS SELECTED FOR TREATMENT. THE STENT WAS DEPLOYED IN THE POLITEAL P1 AND SFA. HOWEVER, THE STENT SEEMS TO BE MUCH SHORTER THAN THE ACTUAL LENGTH WHICH IS DESCRIBED ON THE PACKAGING. THUS, A PASSEO-18 (6/200) WAS USED TO MEASURE THE STENT LENGTH AND THE STENT WAS FOUND TO BE ABOUT 40MM SHORTER THAT THE PASSEO-18.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12185334 ↗

Other STENT, SUPERFICIAL FEMORAL ARTERY devices

All STENT, SUPERFICIAL FEMORAL ARTERY devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page