Orsiro Mission 3/15/140Recalls & reported problems

Biotronik AG · Class 3 · Implant

All models of Orsiro Mission (49)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
10
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 07640130455962), received between Mar 3, 2022 and Apr 29, 2026 — classified as 10 malfunctions.

The most frequently reported specific device problem is “Failure to Advance” (7 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 2 reportsMar 2026: 2 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Advance7
  • Material Deformation2
  • Device Dislodged or Dislocated1

Patient problems

  • No Clinical Signs, Symptoms or Conditions10

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 29, 2026Failure to Advance

    THE ORSIRO MISSION DRUG-ELUTING STENT SYSTEM WAS SELECTED FOR TREATMENT OF A MODERATELY TO SEVERELY CALCIFIED LESION (98 % STENOSIS DEGREE) IN A MODERATELY TORTUOUS SEGMENT OF THE MEDIAL LAD. A PRE-DILATION OF THE LESION WAS PERFORMED. THE AFFECTED DEVICE WAS INTRODUCED INTO THE PATIENT'S BODY BUT COULD NOT CROSS THE LESION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25025072 ↗
  • MalfunctionMar 24, 2026Failure to Advance

    THE ORSIRO MISSION DRUG-ELUTING STENT SYSTEM WAS SELECTED FOR TREATMENT OF A SEVERELY CALCIFIED LESION (80 % STENOSIS DEGREE) IN A SEVERELY TORTUOUS SEGMENT OF THE MEDIAL OM1. A PRE-DILATION OF THE LESION WAS PERFORMED. UNDER USE OF A GUIDELINER GUIDING EXTENSION CATHETER AND A BUDDY WIRE THE AFFECTED DEVICE WAS INTRODUCED INTO THE PATIENT'S BODY BUT COULD NOT CROSS THE LESION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24678878 ↗
  • MalfunctionMar 11, 2026Failure to Advance

    THE ORSIRO MISSION DRUG-ELUTING STENT SYSTEM WAS SELECTED FOR TREATMENT OF A SEVERELY CALCIFIED LESION IN A SEGMENT OF THE PROXIMAL LCX. IT IS UNCLEAR IF A PRE-DILATION OF THE LESION WAS PERFORMED. THE AFFECTED DEVICE WAS INTRODUCED INTO THE PATIENT'S BODY BUT COULD NOT CROSS THE LESION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24566322 ↗
  • MalfunctionFeb 20, 2026Failure to Advance

    THE ORSIRO MISSION DRUG-ELUTING STENT SYSTEM WAS SELECTED FOR TREATMENT OF A LESION IN AN UNKNOWN SEGMENT OF A CORONARY ARTERY. IT IS UNCLEAR IF A PRE-DILATION OF THE LESION WAS PERFORMED. THE AFFECTED DEVICE WAS INTRODUCED INTO THE PATIENT'S BODY BUT COULD NOT CROSS THE LESION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24399556 ↗
  • MalfunctionFeb 20, 2026Failure to Advance

    THE ORSIRO MISSION DRUG-ELUTING STENT SYSTEM WAS SELECTED FOR TREATMENT OF A MILDLY CALCIFIED LESION (90 % STENOSIS DEGREE) IN A MILDLY TORTUOUS SEGMENT OF THE MEDIAL LAD. IT IS UNCLEAR IF A PRE-DILATION OF THE LESION WAS PERFORMED. THE AFFECTED DEVICE WAS INTRODUCED INTO THE PATIENT'S BODY BUT COULD NOT CROSS THE LESION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24399555 ↗
  • MalfunctionJan 23, 2026Failure to Advance

    THE ORSIRO MISSION DRUG-ELUTING STENT SYSTEM WAS SELECTED FOR TREATMENT OF A MILDLY CALCIFIED LESION IN A SEGMENT OF THE MEDIAL LAD. THE AFFECTED DEVICE WAS INTRODUCED INTO THE PATIENT'S BODY BUT COULD NOT CROSS THE LESION. IT WAS POSSIBLE TO CROSS THE LESION USING ANOTHER MANUFACTURERS STENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24159220 ↗
  • MalfunctionNov 19, 2025Failure to Advance; Failure to Advance

    THE ORSIRO MISSION DRUG-ELUTING STENT SYSTEM WAS SELECTED FOR TREATMENT OF A MODERATELY CALCIFIED LESION (15% STENOSIS DEGREE) IN A MODERATELY TORTUOUS PART OF THE MID CX. THE DEVICE DID NOT CROSS LEFT MAIN WITH ACUTE ANGLE TO CX WITH TORTUOSITY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23591206 ↗
  • MalfunctionJan 22, 2024Material Deformation; Material Deformation

    AN ORSIRO MISSION DRUG-ELUTING STENT SYSTEM WAS SELECTED FOR TREATMENT. THE DEVICE WAS ADVANCED AND WOULD NOT CROSS A MODERATELY CALCIFIED LESION (90 PERCENT STENOSIS DEGREE) IN A SEVERELY TORTUOUS PART OF THE MID RCA. ADDITIONAL DILATATION WAS PERFORMED. SINCE THE EDGE OF THIS STENT WAS LIFTED UP, ANOTHER 3.0/15 ORSIRO MISSION STENT WAS USED AND WAS SUCCESSFULLY PLACED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18558251 ↗
  • MalfunctionApr 13, 2022Device Dislodged or Dislocated; Device Dislodged or Dislocated

    AN ORSIRO MISSION DRUG-ELUTING STENT SYSTEM WAS SELECTED FOR TREATMENT. THE ORSIRO MISSION US STENT DISLODGED FROM THE BALLOON DURING THE ATTEMPT TO CROSS THE LESION. IT WAS POSSIBLE TO LOCATE THE STENT AND THE DELIVERY BALLOON WAS USED TO GO IN THE STENT AND DEPLOY THE STENT IN PLACE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14103647 ↗
  • MalfunctionMar 3, 2022Material Deformation; Material Deformation

    AN ORSIRO MISSION DRUG-ELUTING STENT SYSTEM WAS SELECTED FOR TREATMENT OF A MILDLY CALCIFIED LESION (90 PERCENT STENOSIS DEGREE) IN THE MILDLY TORTUOUS MID RCA. IT WAS ATTEMPTED TO IMPLANT THE ORSIRO MISSION DISTAL TO A PREVIOUSLY PLACED STENT. BUT DESPITE PRE-DILATATION, THE PREVIOUSLY IMPLANTED STENT COULD NOT BE CROSSED WITH THE DEVICE. AFTER WITHDRAWAL, A STENT DEFORMATION WAS DETECTED AT THE PROXIMAL EDGE. ANOTHER STENT WAS USED TO COMPLETE THE INTERVENTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13660598 ↗

Other Coronary drug-eluting stent devices

All Coronary drug-eluting stent devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page