This is a Thomomen Medical SPI Element dental implant, a screw-shaped implant placed into the jawbone. The 47 reports mostly describe the implant failing to fuse with the bone or losing that fusion later, along with loosening and bone loss around the implant. All 47 reports involve injuries, with no deaths mentioned. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 47
- Deaths reported
- 0
- Injuries reported
- 47
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 47 adverse event reports that list this exact device (DI 07640156471397), received between Feb 1, 2018 and Oct 27, 2025 — classified as 47 injuries.
The most frequently reported specific device problem is “Failure to Osseointegrate” (38 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Osseointegrate38
- Loss of Osseointegration9
Patient problems
- Inadequate Osseointegration35
- No Code Available12
Recent adverse event reports
The 25 most recent of 47 reports, in the reporter's own words as published by the FDA.
InjuryOct 27, 2025Loss of Osseointegration; Loss of Osseointegration
LOSS OF OSSEOINTEGRATION, BONE RESORPTION.
Patient problems: Inadequate Osseointegration
MAUDE report 23388811 ↗InjuryMay 2, 2025Failure to Osseointegrate; Failure to Osseointegrate
PRIMARY STABILITY NOT ACHIEVED, MOBILITY - ANOTHER SIZE OF IMPLANT WAS CHOSEN.
Patient problems: Inadequate Osseointegration
MAUDE report 21949089 ↗InjuryMar 27, 2025Failure to Osseointegrate; Failure to Osseointegrate
InjuryNov 12, 2024Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION, SWELLING, INFLAMMATION.
Patient problems: Inadequate Osseointegration
MAUDE report 20665158 ↗InjuryAug 7, 2024Failure to Osseointegrate; Failure to Osseointegrate
PRIMARY STABILITY NOT ACHIEVED, IMPLANT WASN'T COMPLETELY COVERED WITH BONE, NO THREAD TAP USED, RADIATION TX-HEAD / NECK AREA, MOBILITY
Patient problems: Inadequate Osseointegration
MAUDE report 19927243 ↗InjuryAug 3, 2024Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION, MOBILITY.
Patient problems: Inadequate Osseointegration
MAUDE report 19901403 ↗InjuryJul 5, 2024Loss of Osseointegration; Loss of Osseointegration
LOSS OF OSSEOINTEGRATION, IMPLANT ACHIEVED OSSEOINTEGRATION, PRIMARY STABILITY WAS ACHIEVED, IMPLANT WAS COMPLETELY COVERED WITH BONE, NO THREAD TAP USED, BONE RESORPTION, PERI-IMPLANTITIS.
Patient problems: Inadequate Osseointegration
MAUDE report 19678391 ↗InjuryJun 5, 2024Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION, PRIMARY STABILITY WAS ACHIEVED, IMPLANT WAS COMPLETELY COVERED WITH BONE, NO THREAD TAP USED, DIABETES MELLITUS, SMOKER, PRECEDING/SIMULTANEOUS BONE AUGMENTATION, INFLAMMATION.
Patient problems: Inadequate Osseointegration
MAUDE report 19465640 ↗InjuryMay 10, 2024Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION, UNDERBITE TOOTH.
Patient problems: Inadequate Osseointegration
MAUDE report 19283585 ↗InjuryMar 18, 2024Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION, SMOKER, PAIN, INFLAMMATION, MOBILITY ((B)(4) ARE SAME PATIENT).
Patient problems: Inadequate Osseointegration
MAUDE report 18920643 ↗InjuryMar 18, 2024Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION, SMOKER, PAIN, INFLAMMATION, MOBILITY ((B)(4) ARE SAME PATIENT).
Patient problems: Inadequate Osseointegration
MAUDE report 18920634 ↗InjuryFeb 17, 2024Failure to Osseointegrate; Failure to Osseointegrate
PRIMARY STABILITY NOT ACHIEVED, IMPLANT WASN'T COMPLETELY COVERED WITH BONE, NO THREAD TAP USED, MOBILITY.
Patient problems: Inadequate Osseointegration
MAUDE report 18728184 ↗InjuryJul 14, 2023Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION, INADEQUATE BONE QUANTITY.
Patient problems: Inadequate Osseointegration
MAUDE report 17323926 ↗InjuryJul 12, 2023Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION, PRIMARY STABILITY WAS ACHIEVED, IMPLANT WAS COMPLETELY COVERED WITH BONE, IMMEDIATE IMPLANTATION, MOBILITY.
Patient problems: Inadequate Osseointegration
MAUDE report 17304653 ↗InjuryJun 30, 2023Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION, PRIMARY STABILITY WAS ACHIEVED.
Patient problems: Inadequate Osseointegration
MAUDE report 17236197 ↗InjuryJun 20, 2023Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION, ((B)(6) ARE SAME PATIENT).
Patient problems: Inadequate Osseointegration
MAUDE report 17160833 ↗InjuryJun 5, 2023Loss of Osseointegration; Loss of Osseointegration
LOSS OF OSSEOINTEGRATION, PERI-IMPLANTITIS, INFLAMMATION, MOBILITY.
Patient problems: Inadequate Osseointegration
MAUDE report 17056747 ↗InjuryApr 23, 2023Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION, PRIMARY STABILITY WAS ACHIEVED, IMPLANT WASN'T COMPLETELY COVERED WITH BONE, NO THREAD TAP USED, IMMEDIATE IMPLANTATION, MOBILITY.
Patient problems: Inadequate Osseointegration
MAUDE report 16792773 ↗InjuryJan 24, 2023Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION.
Patient problems: Inadequate Osseointegration
MAUDE report 16231555 ↗InjuryJan 9, 2023Failure to Osseointegrate; Failure to Osseointegrate
PRIMARY STABILITY NOT ACHIEVED, IMPLANT WASN'T COMPLETELY COVERED WITH BONE, THREAD TAP USED, CHEMOTHERAPY AROUND TIME OF IMPLANT PLACEMENT, DIABETES MELLITUS, COMPLICATION IN SITE PREPARATION, INADEQUATE BONE QUALITY/QUANTITY, MOBILITY.
Patient problems: Inadequate Osseointegration
MAUDE report 16120644 ↗InjuryOct 18, 2022Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION, PRIMARY STABILITY WAS ACHIEVED, IMPLANT WAS COMPLETELY COVERED WITH BONE, THREAD TAP USED, MOBILITY.
Patient problems: Inadequate Osseointegration
MAUDE report 15623447 ↗InjuryOct 17, 2022Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION, PRIMARY STABILITY WAS ACHIEVED, IMPLANT WASN'T COMPLETELY COVERED WITH BONE, NO THREAD TAP USED, PSYCHOLOGICAL DISORDER, SMOKER, BONE RESORPTION, INFECTION, BLEEDING.
Patient problems: Inadequate Osseointegration
MAUDE report 15615351 ↗InjuryOct 10, 2022Failure to Osseointegrate; Failure to Osseointegrate
PRIMARY STABILITY NOT ACHIEVED, IMPLANT WASN'T COMPLETELY COVERED WITH BONE, MOBILITY.
Patient problems: Inadequate Osseointegration
MAUDE report 15572249 ↗InjurySep 6, 2022Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT DIDN'T ACHIEVE OSSEOINTEGRATION, PRIMARY STABILITY WAS ACHIEVED, IMPLANT WAS COMPLETELY COVERED WITH BONE, NO THREAD TAP USED, COMPLICATION IN SITE PREPARATION, INADEQUATE BONE QUALITY/QUANTITY, PAIN, MOBILITY.
Patient problems: Inadequate Osseointegration
MAUDE report 15359811 ↗InjuryAug 6, 2022Loss of Osseointegration; Loss of Osseointegration
LOSS OF OSSEOINTEGRATION, IMPLANT ACHIEVED OSSEOINTEGRATION, PRIMARY STABILITY WAS ACHIEVED, IMPLANT WAS COMPLETELY COVERED WITH BONE, THREAD TAP USED, PAIN, MOBILITY ((B)(6) ARE SAME PATIENT).
Patient problems: Inadequate Osseointegration
MAUDE report 15180525 ↗
Other Implant, Endosseous, Root-Form devices
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM43,616 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM40,404 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM27,400 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,621 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLA Titanium BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,298 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM23,448 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,320 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,267 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page