Skip to content

Neodent 109.978Recalls & reported problems

JJGC Indústria e Comércio de Materiais Dentários S/A. · GM HELIX IMPLANT · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Quick summary

This Neodent GM Helix dental implant is placed in the jawbone to support a replacement tooth. Of its 6,220 reports, all are injury reports and none are deaths. Many describe the implant failing to bond with the bone, and some mention patients with scar-like tissue, pain or infection. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
6,402
Deaths reported
0
Injuries reported
6,402
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6,402 adverse event reports that list this exact device (DI 07899878024491), received between Dec 3, 2018 and Sep 28, 2026 — classified as 6,402 injuries.

The most frequently reported specific device problem is “Failure to Osseointegrate” (5,469 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 78 reportsJan 2024: 43 reportsFeb 2024: 77 reportsMar 2024: 59 reportsApr 2024: 88 reportsMay 2024: 106 reportsJun 2024: 90 reportsJul 2024: 77 reportsAug 2024: 136 reportsSep 2024: 109 reportsOct 2024: 136 reportsNov 2024: 132 reportsDec 2024: 92 reportsJan 2025: 127 reportsFeb 2025: 102 reportsMar 2025: 147 reportsApr 2025: 57 reportsMay 2025: 0 reportsJun 2025: 392 reportsJul 2025: 133 reportsAug 2025: 152 reportsSep 2025: 104 reportsOct 2025: 142 reportsNov 2025: 188 reportsDec 2025: 312 reportsJan 2026: 200 reportsFeb 2026: 188 reportsMar 2026: 205 reportsApr 2026: 187 reportsMay 2026: 174 reportsJun 2026: 190 reportsJul 2026: 201 reportsAug 2026: 219 reportsSep 2026: 209 reportsOct 2026: 0 reportsNov 2026: 0 reports202420252026392
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate5,469
  • Loss of Osseointegration611
  • Adverse Event Without Identified Device or Use Problem243
  • Difficult to Insert44
  • Fracture36
  • Separation Failure9

Patient problems

  • No Clinical Signs, Symptoms or Conditions3,879
  • Fibrosis1,314
  • Pain1,199
  • Unspecified Infection1,113
  • Inflammation327
  • Fistula253
  • Swelling/ Edema247
  • Hemorrhage/Blood Loss/Bleeding210

Recent adverse event reports

The 25 most recent of 6,402 reports, in the reporter's own words as published by the FDA.

  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 12. On 2026-09-01, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922983 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 23. On 2026-08-26, non-osseointegration was verified. Patient presented with fair oral hygiene. The device was forwarded to the manufacturer. At the event the patient experienced: Infection and Fistula. No further patient complications were reported.

    Patient problems: Fistula; Unspecified Infection

    MAUDE report 50922954 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 42. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type III. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922940 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6)2026 in ADA 8. Details of surgery: Primary stability not achieved, Implant surface not completely covered with bone, Ridge augmentation and Immediate extraction site. On (b)(6)2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922935 ↗
  • InjurySep 28, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6)2026 in ADA 20. On (b)(6)2026, loss of osseointegration was verified. Patient presented with bone type III. The device was forwarded to the manufacturer. At the event the patient experienced: Pain and Mobility. No further patient complications were reported.

    Patient problems: Fibrosis; Pain

    MAUDE report 50922932 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 5. Details of surgery: Primary stability not achieved, Implant surface not completely covered with bone, Ridge augmentation and Immediate extraction site. On 2026-08-13, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922928 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted 2026(b)(6) in the patient's mouth. On 2026(b)(6), non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922912 ↗
  • InjurySep 28, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 36. Details of surgery: Implant surface not completely covered with bone. On (b)(6) 2026, loss of osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Mobility. No further patient complications were reported.

    Patient problems: Fibrosis

    MAUDE report 50922881 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2025 in FDI 45. On (b)(6) 2026, non-osseointegration was verified. Patient presented with inadequate bone quality/quantity. The device was forwarded to the manufacturer. At the event the patient experienced: Infection, Mobility and Abscess. No further patient complications were reported.

    Patient problems: Abscess; Fibrosis; Unspecified Infection

    MAUDE report 50922838 ↗
  • InjurySep 28, 2026Loss of Osseointegration

    The clinician reports the implant was inserted (b)(6) 2025 in FDI 34. On (b)(6) 2026, loss of osseointegration was verified. Patient presented with inadequate bone quality/quantity. The device was forwarded to the manufacturer. At the event the patient experienced: Pain and Mobility. No further patient complications were reported.

    Patient problems: Fibrosis; Pain

    MAUDE report 50922837 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted 2026(b)(6) in the patient's mouth. On 2026-(b)(6), non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922835 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922809 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922774 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted on (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922757 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922756 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 9. On 2026-08-25, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Pain, Mobility and Fistula. No further patient complications were reported.

    Patient problems: Fibrosis; Fistula; Pain

    MAUDE report 50922749 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 29. Details of surgery: Primary stability not achieved. On 2026-08-24, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Infection, Mobility, Bleeding and Inflammation. No further patient complications were reported.

    Patient problems: Fibrosis; Hemorrhage/Blood Loss/Bleeding; Inflammation; Unspecified Infection

    MAUDE report 50922721 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2025 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. At the event the patient experienced: Infection, Bleeding and Fistula. No further patient complications were reported.

    Patient problems: Fistula; Hemorrhage/Blood Loss/Bleeding; Unspecified Infection

    MAUDE report 50922648 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 32. On (b)(6) 2026, non-osseointegration was verified. Patient presented with fair oral hygiene. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922619 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 22. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922611 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in FDI 36. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type III and fair oral hygiene. No product was returned to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922444 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in the patient's mouth. On (b)(6) 2026, non-osseointegration was verified. Patient presented with bone type IV and bruxism. The device was forwarded to the manufacturer. At the event the patient experienced: Fistula. No further patient complications were reported.

    Patient problems: Fistula

    MAUDE report 50922271 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2026 in ADA 7. Details of surgery: Primary stability not achieved, Implant surface not completely covered with bone, Ridge augmentation and Immediate extraction site. On (b)(6) 2026, non-osseointegration was verified. The device was forwarded to the manufacturer. There were no reported patient injuries or complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50922221 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2025 in FDI 26. On (b)(6) 2026, non-osseointegration was verified. Patient presented with inadequate bone quality/quantity. The device was forwarded to the manufacturer. At the event the patient experienced: Abscess. No further patient complications were reported.

    Patient problems: Abscess

    MAUDE report 50922201 ↗
  • InjurySep 28, 2026Failure to Osseointegrate

    The clinician reports the implant was inserted (b)(6) 2025 in FDI 25. On 2026-09-03, non-osseointegration was verified. Patient presented with inadequate bone quality/quantity. The device was forwarded to the manufacturer. At the event the patient experienced: Pain and Mobility. No further patient complications were reported.

    Patient problems: Fibrosis; Pain

    MAUDE report 50922198 ↗

FDA clearance and classification

The FDA regulates product code DZE (implant, endosseous, root-form) under 21 CFR 872.3640 as a Class II device. 21 CFR 872.3640 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Neodent 109.978

Has the Neodent 109.978 been recalled?

No FDA recall record in our data names this exact device identifier (DI 07899878024491), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Neodent 109.978?

The FDA's MAUDE database lists 6,402 adverse event reports for this device, received between Dec 3, 2018 and Sep 28, 2026. In those reports, the most common specific device problems are “Failure to Osseointegrate” (5,469), “Loss of Osseointegration” (611) and “Difficult to Insert” (44); the most common patient problems are “Fibrosis” (1,314), “Pain” (1,199) and “Unspecified Infection” (1,113). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Neodent 109.978?

None of the reports are classified as deaths, 6,402 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Neodent 109.978 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the Neodent 109.978, and is it still sold?

The FDA's device database lists JJGC Indústria e Comércio de Materiais Dentários S/A. as the company responsible for it (brand Neodent, model 109.978). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page