CARBOMEDICS STANDARD A5-019Recalls & reported problems
Corcym Srl · Class 3 · Implant
All models of CARBOMEDICS STANDARD (12)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 1
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 08022057012609), received between May 18, 2017 and Oct 20, 2022 — classified as 1 death, 1 injury.
The most frequently reported specific device problem is “Difficult to Open or Close” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Difficult to Open or Close1
- Incomplete Coaptation1
- Material Split, Cut or Torn1
Patient problems
- Death1
- Insufficient Information1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryOct 20, 2022Material Split, Cut or Torn; Material Split, Cut or Torn
ON (B)(6) 2022, DURING THE IMPLANTING PROCEDURE OF A CARBOMEDICS STANDARD AORTIC MECHANICAL HEART VALVE, A5-019, THE DAMAGE OF THE VALVE SEWING RINGS ¿ SLIT WAS NOTED WHICH RESULTED IN FAILURE OF THE SUTURES OF THE VALVE AND WHICH THREATENED THE LIFE OF THE PATIENT. THEREAFTER, A NEW VALVE WAS IMPLANTED IN THE PATIENT. BASED ON THE MEDICAL JUDGEMENT RECEIVED, AT THE BEGINNING OF THE OPERATION, NO UNUSUAL THING WAS NOTICED WITH THE VALVE. THE PROBLEM WAS NOTED DURING THE PROCEDURE, WHEN THE STITCHES WERE PLACED IN THE SEWING RING, SO TEARS ARE CAUSED DURING THE PASSAGE OF THE STITCHES THROUGH THE SEWING RING. THEN, IT WAS DECIDED TO USE ANOTHER VALVE AND PROCEDURE WAS PERFORMED SUCCESSFULLY AND THE PATIENT WAS RELEASED FROM THE HOSPITAL.
Patient problems: Insufficient Information
MAUDE report 15642901 ↗DeathMay 18, 2017Incomplete Coaptation; Difficult to Open or Close; Incomplete Coaptation; Difficult to Open or Close
ON (B)(6) 2017, THE PHYSICIAN IMPLANTED MECHANICAL CARBOMEDICS 19 AORTIC. ON (B)(6) 2017 THE PATIENT DIED.
Patient problems: Death
MAUDE report 6577227 ↗
Other HEART-VALVE, MECHANICAL devices
- On-X Mitral Heart Valve with Conform-X Sewing Ring ONXMC-25/33On-X Life Technologies, Inc. · Heart-Valve, Mechanical1 recall1 death34 reports
- SJM Regent™ AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths70 reports
- SJM Regent™ AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL5 deaths66 reports
- SJM Regent™ 23AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths44 reports
- CARBOMEDICS SUPRA-ANNULAR (TOP HAT) S5-021Corcym Srl · HEART-VALVE, MECHANICAL7 deaths37 reports
- Regent™ 21AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths35 reports
- Regent™ 23AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL2 deaths33 reports
- Regent™ 19AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL31 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page