CARBOMEDICS REDUCED R5-025Recalls & reported problems

Corcym Srl · Class 3 · Implant

All models of CARBOMEDICS REDUCED (6)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
9
Deaths reported
0
Injuries reported
9
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 08022057012791), received between Dec 17, 2019 and Nov 21, 2024 — classified as 9 injuries.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (7 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 2 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information7
  • Detachment of Device or Device Component2
  • Gradient Increase2
  • Adverse Event Without Identified Device or Use Problem1
  • No Apparent Adverse Event1

Patient problems

  • Endocarditis3
  • Aortic Insufficiency2
  • Aortic Valve Stenosis2
  • Embolism2
  • Insufficient Information2
  • No Information2
  • Paresis2
  • Stroke/CVA2

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 21, 2024Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information

    THE MANUFACTURER WAS NOTIFIED BY A CARDIOLOGIST ABOUT A PATIENT WITH A CARBOMEDICS AORTIC MECHANICAL PROSTHESIS EXPERIENCING RECURRENT EMBOLIZATION. AS REPORTED, THE EMBOLIC EVENTS OCCURRED DESPITE EXCELLENT INR AND ABSENCE OF COAGULOPATHY DISORDERS. BASED ON THE INFORMATION RECEIVED, THERE IS NO VISIBLE DYSFUNCTION OF THE PROSTHESIS OR VALVE THROMBOSIS.

    Patient problems: Embolism/Embolus; Endocarditis

    MAUDE report 20746180 ↗
  • InjuryOct 18, 2024No Apparent Adverse Event; Insufficient Device Problem Information; No Apparent Adverse Event; Insufficient Device Problem Information

    THE MANUFACTURER BECAME AWARE THROUGH DEVICE TRACKING INFORMATION THAT ON 29 JAN 2018, A CARBOMEDICS REDUCED AORTIC MECHANICAL HEART VALVE R5-025 WAS IMPLANTED AND THEN EXPLANTED INTRA-OPERATIVELY. AS FURTHER REPORTED, REASON FOR EXPLANT WAS THAT THE DEVICE DIDN'T POSITION WELL. IT WAS CONFIRMED THAT THERE WAS NO DEVICE MALFUNCTION IDENTIFIED AND NO ADDED TIME AS A RESULT OF THE EVENT. FURTHERMORE, THE MANUFACTURER WAS INFORMED THAT THE DECISION TO IMPLANT A BIOPROSTHESIS WAS TAKEN DURING THE SURGERY AND THE CARBOMEDICS VALVE WAS REPLACED WITH A SUTURED PERICARDIAL VALVE FROM A DIFFERENT MANUFACTURER (EDWARDS LIFESCIENCES 25MM 2800TFX). REPORTEDLY, THE PATIENT WAS STABLE THROUGHOUT THE SURGERY, WHICH WAS COMPLETED WITHOUT COMPLICATIONS AND A GOOD OUTCOME.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 20482308 ↗
  • InjuryOct 18, 2024Insufficient Device Problem Information; Insufficient Device Problem Information

    THE MANUFACTURER BECAME AWARE THROUGH DEVICE TRACKING INFORMATION THAT ON (B)(6) 2018, A CARBOMEDICS REDUCED AORTIC MECHANICAL HEART VALVE R5-025 WAS IMPLANTED AND THEN EXPLANTED INTRA-OPERATIVELY. NO ALLEGATION OF DEVICE DYSFUNCTION NOR PATIENT INJURY HAS BEEN RECEIVED FROM THE HEALTHCARE FACILITY. NO FURTHER INFORMATION IS AVAILABLE AT THIS TIME.

    Patient problems: Insufficient Information

    MAUDE report 20482070 ↗
  • InjuryDec 7, 2020Detachment of Device or Device Component; Detachment of Device or Device Component

    ON (B)(6) 2020, A PATIENT WITH SEVERE AORTIC STENOSIS OF THE BICUSPID AORTIC VALVE AND ASCENDING AORTA DILATATION, RECEIVED A CARBOMEDICS REDUCED R5-025 IN AORTIC POSITION. THE PATIENT ALSO RECEIVED AN ASCENDING AORTA REPLACEMENT WITH A DACRON CONDUIT JOTEC 28MM DURING THE SAME PROCEDURE, WHICH WAS COMPLETED WITHOUT SURGICAL INCIDENTS. AFTER DECLAMPING THE AORTA, WITH THE PATIENT STILL UNDER CARDIOPULMONARY BYPASS (CPB), THE TRANSESOPHAGEAL ECHOCARDIOGRAPHY (TEE) SHOWED A REGULAR FUNCTION OF THE PROTHESIS (MOTION OF BOTH LEAFLETS, NO SIGNIFICANT LEAKS). UPON WEANING FROM CPB, THERE WAS A SIGNIFICANT CLINICAL DETERIORATION. A NEW TEE WAS PERFORMED IN WHICH THERE WAS EVIDENCE OF DYSFUNCTIONAL LV, SEVERELY DILATED WITH SEVERE MI AND SEVERE INTRAPROSTHETIC AORTIC REGURGITATION. THE MOVEMENT OF ONE LEAFLET WAS CORRECTLY VISUALIZED BUT NOT THE OTHER. GIVEN THIS FINDINGS, A LEAFLET BLOCK WAS SUSPECTED. AS SUCH, THE AORTA WAS RE-CLAMPED, THE DACRON GRAFT WAS OPENED FOR EXPLORATION OF THE PROSTHESIS, AND IT WAS IDENTIFIED THAT ONE LEAFLET WAS MISSING. THE PROSTHESIS WAS REMOVED, THE LEFT VENTRICULAR CAVITY WAS CHECKED WITHOUT ANY FINDING, AND A NEW CARBOMEDICS REDUCED R5-025 WAS IMPLANTED.

    Patient problems: Aortic Insufficiency; Embolism

    MAUDE report 10963361 ↗
  • InjuryDec 7, 2020Detachment of Device or Device Component; Detachment of Device or Device Component

    ON (B)(6) 2020, A PATIENT WITH SEVERE AORTIC STENOSIS OF THE BICUSPID AORTIC VALVE AND ASCENDING AORTA DILATATION, RECEIVED A CARBOMEDICS REDUCED R5-025 IN AORTIC POSITION. THE PATIENT ALSO RECEIVED AN ASCENDING AORTA REPLACEMENT WITH A DACRON CONDUIT JOTEC 28MM DURING THE SAME PROCEDURE, WHICH WAS COMPLETED WITHOUT SURGICAL INCIDENTS. AFTER DECLAMPING THE AORTA, WITH THE PATIENT STILL UNDER CARDIOPULMONARY BYPASS (CPB), THE TRANSESOPHAGEAL ECHOCARDIOGRAPHY (TEE) SHOWED A REGULAR FUNCTION OF THE PROTHESIS (MOTION OF BOTH LEAFLETS, NO SIGNIFICANT LEAKS). UPON WEANING FROM CPB, THERE WAS A SIGNIFICANT CLINICAL DETERIORATION. A NEW TEE WAS PERFORMED IN WHICH THERE WAS EVIDENCE OF DYSFUNCTIONAL LV, SEVERELY DILATED WITH SEVERE MI AND SEVERE INTRAPROSTATIC AORTIC REGURGITATION. THE MOVEMENT OF ONE LEAFLET WAS CORRECTLY VISUALIZED BUT NOT THE OTHER. GIVEN THIS FINDINGS, A LEAFLET BLOCK WAS SUSPECTED. AS SUCH, THE AORTA WAS RE-CLAMPED, THE DACRON GRAFT WAS OPENED FOR EXPLORATION OF THE PROSTHESIS, AND IT WAS IDENTIFIED THAT ONE LEAFLET WAS MISSING. THE PROSTHESIS WAS REMOVED, THE LEFT VENTRICULAR CAVITY WAS CHECKED WITHOUT ANY FINDING, AND A NEW CARBOMEDICS REDUCED R5-025 WAS IMPLANTED. T

    Patient problems: Aortic Insufficiency; Embolism

    MAUDE report 10963284 ↗
  • InjuryAug 11, 2020Insufficient Device Problem Information; Insufficient Device Problem Information

    ON (B)(6) 2017, CARBOMEDICS REDUCED VALVE R5-025 WAS IMPLANTED IN AORTIC POSITION. ON (B)(6) 2020, THE DEVICE WAS EXPLANTED AND REPLACED WITH A BICARBON SLIMLINE AORTIC VALVE ART23LSA. NO FURTHER INFORMATION WAS RECEIVED.

    Patient problems: No Information

    MAUDE report 10393971 ↗
  • InjuryAug 11, 2020Insufficient Device Problem Information; Insufficient Device Problem Information

    ON (B)(6) 2017, CARBOMEDICS REDUCED VALVE R5-025 WAS IMPLANTED IN AORTIC POSITION. ON (B)(6) 2020, THE DEVICE WAS EXPLANTED AND REPLACED WITH A BICARBON SLIMLINE AORTIC VALVE ART23LSA. NO FURTHER INFORMATION WAS RECEIVED.

    Patient problems: No Information

    MAUDE report 10393965 ↗
  • InjuryDec 17, 2019Gradient Increase; Insufficient Device Problem Information; Gradient Increase; Insufficient Device Problem Information

    ON (B)(6) 2013, A PATIENT RECEIVED A CARBOMEDICS REDUCED HEART VALVE R5-025 IN AORTIC POSITION. ON (B)(6) 2017, THE PATIENT EXPERIENCED A STROKE AND THE DEVICE IS REPORTED AS THE SUSPECTED CAUSE. ON (B)(6) 2017, THE DEVICE WAS EXPLANTED. THE PATIENT EXPERIENCED RIGHT HEMIPARESIS AND GLOBAL APHASIA FOLLOWING THIS EVENT. DESPITE THE EVENT REFERS TO A MALFUNCTIONING PROSTHESIS, THESE MALFUNCTIONS ARE NOT FURTHER SPECIFIED.

    Patient problems: Aortic Valve Stenosis; Endocarditis; Paresis; Stroke/CVA; Thromboembolism

    MAUDE report 9485365 ↗
  • InjuryDec 17, 2019Gradient Increase; Insufficient Device Problem Information; Gradient Increase; Insufficient Device Problem Information

    ON (B)(6) 2013, A PATIENT RECEIVED A CARBOMEDICS REDUCED HEART VALVE R5-025 TO REPLACE THE NATIVE BICUSPID VALVE (PRE-OPERATIVE DIAGNOSIS: SEVERE AORTIC INSUFFICIENCY AND ANEURYSM OF THE ASCENDING AORTA). DURING THE SAME PROCEDURE, A LONGITUDINAL REDUCTION OF THE ASCENDING AORTA WAS ALSO PERFORMED. AN UNEVENTFUL POSTOPERATIVE COURSE WAS REPORTED AND AT DISCHARGE, A GOOD DEVICE FUNCTIONALITY WAS DETECTED. THE MANUFACTURER WAS INFORMED THAT ON (B)(6) 2017, THE PATIENT WAS HOSPITALIZED DUE TO STROKE, RIGHT HEMIPARESIS, AND GLOBAL APHASIA. THE EVENT IS REPORTEDLY LIKELY RESULTING FROM THROMBOEMBOLISM ORIGINATING FROM THE MECHANICAL VALVE. THE ECHO PERFORMED IN(B)(6) 2017 DETECTED THE PRESENCE OF PANNUS DEPOSITION ON THE PROSTHESIS, POSSIBLE THROMBUS DEPOSITIONS AND DYSFUNCTION OF THE PROSTHESIS (STENOSIS). ENDOCARDITIS WAS SUSPECTED DUE TO THE REPORTED SYMPTOMS OF FEVER. ON (B)(6) 2017, 4-WEEKS OF ANTIBIOTIC THERAPY WAS INITIATED TO STABILIZE THE CLINIC STATUS OF THE PATIENT. ON (B)(6) 2017, A RE-INTERVENTION WAS PERFORMED TO REPLACE THE MECHANICAL VALVE WITH A BIOLOGICAL PROSTHESIS. DURING THE PROCEDURE, A VENTRICLE-AORTIC DISCONNECTION WAS NOTED, SIMILAR TO PREVIOUS ENDOCARDITIS. THE

    Patient problems: Aortic Valve Stenosis; Endocarditis; Paresis; Stroke/CVA; Thromboembolism

    MAUDE report 9485269 ↗

Other HEART-VALVE, MECHANICAL devices

All HEART-VALVE, MECHANICAL devices →