CARBOMEDICS OPTIFORM F7-025Recalls & reported problems
Corcym Srl · Class 3 · Implant
All models of CARBOMEDICS OPTIFORM (6)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 08022057012845), received between Dec 17, 2019 and Aug 26, 2022 — classified as 2 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Difficult or Delayed Positioning” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Difficult or Delayed Positioning2
- Difficult to Open or Close2
Patient problems
- No Information2
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 26, 2022Difficult to Open or Close; Difficult to Open or Close
THE MANUFACTURER WAS INFORMED OF THE FOLLOWING EVENT. BEFORE IMPLANTING THE VALVE, SIZING WAS PERFORMED (USING CORCYM SIZER) WITHOUT ANY PROBLEM AND OPTIFORM PROSTHETIC MITRAL HEART VALVE F7-025 WAS CHOSEN TO BE IMPLANTED. THE VALVE WAS TESTED WITHOUT ANY ISSUE BEING IDENTIFIED. AFTER IMPLANTING THE VALVE, IT WAS DETECTED BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY (TEE) THAT THE VALVE COULD NOT OPEN/CLOSE. REPORTEDLY, THE VALVE COULD NOT MOVE AT ALL. AS SUCH, THE VALVE WAS EXPLANTED. USING ECMO IT HAD TAKEN 100MINS (40 MINS FOR THE NORMAL SITUATION); AND REPLACING IT WITH NON-CORCYM VALVE SIZE 25. PROCEDURE WAS COMPLETED WELL, AND THE PATIENT OUTCOME WAS FINE. BASED ON ADDITIONAL INFORMATION RECEIVED, ALMOST TOTAL RESECTION OF THE NATIVE VALVE WAS PERFORMED, BUT SOME CHORDAE PAPILLARY MUSCLE WAS KEPT. REPORTEDLY, BEFORE CLOSING THE HEART, THE F7-025 VALVE WAS TESTED WITH VALVE DETECTOR AND THE RESULT WAS GOOD. AFTER CLOSING THE HEART, USING ECHOCARDIOGRAPHER, AT THE BEGINNING (ABOUT 10 SECONDS), THE VALVE FUNCTIONALITY WAS OKAY, BUT SUDDENLY THE LEAFLET WAS BLOCKED. THUS, THE DECISION TO REPLACE IT WITH A NON-CORCYM VALVE. THERE WERE NO ABNORMAL PATIENT GEOMETRIES AND NO CONCOMITANT PROCE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15305769 ↗MalfunctionNov 6, 2020Difficult to Open or Close; Difficult to Open or Close
ON (B)(6) 2020, A PATIENT WAS INTENDED TO RECEIVE A CARBOMEDICS OPTIFORM VALVE F7-025 IN MITRAL POSITION. DURING THE PROCEDURE, A POTENTIAL LEAFLET DYSFUNCTION WAS IDENTIFIED DURING THE SUTURING OF THE VALVE (I.E. LEAFLET REPORTEDLY "STUCK") AND THE DEVICE WAS ULTIMATELY REMOVED. A NEW VALVE OF THE SAME MODEL F7-025 WAS IMPLANTED AND THE OPERATION WAS SUCCESSFULLY COMPLETED. IT IS REPORTED THAT THE LEAFLET FUNCTIONALITY WAS TESTED WITH THE DEDICATED LEAFLET TESTER PROVIDED. THERE WAS NO IMPACT FOR THE PATIENT, WHO PERFORMS AND RECOVERS WELL.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10802000 ↗InjuryDec 17, 2019Difficult or Delayed Positioning; Difficult or Delayed Positioning
ON (B)(6) 2019 A PATIENT WAS INTENDED TO RECEIVE A CARBOMEDICS OPTIFORM F7-025 MITRAL VALVE AS PART OF AN MVR. THE MANUFACTURER WAS NOTIFIED THAT AFTER THE IMPLANTATION OF HEART VALVE, WHEN THE SITE TRIED TO ROTATE THE DEVICE, THEY EXPERIENCED DIFFICULTIES AND THE VALVE DIDN'T ROTATED. THE SITE EXPLANTED THE VALVE. NO FURTHER INFORMATION WAS RECEIVED.
Patient problems: No Information
MAUDE report 9485056 ↗InjuryDec 17, 2019Difficult or Delayed Positioning; Difficult or Delayed Positioning
ON (B)(6) 2019 A PATIENT WAS INTENDED TO RECEIVE A CARBOMEDICS OPTIFORM F7-025 MITRAL VALVE AS PART OF AN MVR. THE MANUFACTURER WAS NOTIFIED THAT AFTER THE IMPLANTATION OF HEART VALVE, WHEN THE SITE TRIED TO ROTATE THE DEVICE, THEY EXPERIENCED DIFFICULTIES AND THE VALVE DIDN'T ROTATED. THE SITE EXPLANTED THE VALVE. NO FURTHER INFORMATION WAS RECEIVED.
Patient problems: No Information
MAUDE report 9484910 ↗
Other HEART-VALVE, MECHANICAL devices
- On-X Mitral Heart Valve with Conform-X Sewing Ring ONXMC-25/33On-X Life Technologies, Inc. · Heart-Valve, Mechanical1 recall1 death34 reports
- SJM Regent™ AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths70 reports
- SJM Regent™ AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL5 deaths66 reports
- SJM Regent™ 23AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths44 reports
- CARBOMEDICS SUPRA-ANNULAR (TOP HAT) S5-021Corcym Srl · HEART-VALVE, MECHANICAL7 deaths37 reports
- Regent™ 21AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths35 reports
- Regent™ 23AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL2 deaths33 reports
- Regent™ 19AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL31 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page