CARBOMEDICS CARBO-SEAL AP-021Recalls & reported problems
Corcym Srl · Class 3 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08022057013460), received between May 23, 2025 and May 23, 2025 — classified as 1 injury.
The most frequently reported specific device problem is “Device Markings/Labelling Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device Markings/Labelling Problem1
- Inadequacy of Device Shape and/or Size1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 23, 2025Inadequacy of Device Shape and/or Size; Device Markings/Labelling Problem; Inadequacy of Device Shape and/or Size; Device Markings/Labelling Problem
THE MANUFACTURER WAS NOTIFIED OF AN INCIDENT INVOLVING A FAILURE TO IMPLANT AND A LABELLING DISCREPANCY ASSOCIATED WITH A CARBOSEAL ASCENDING AORTIC PROSTHESIS, MODEL AP-021. ACCORDING TO THE REPORT, AFTER COMPLETING THE SIZING PROCEDURE USING THE SIZER ACCESSORIES, THE SURGICAL TEAM ENCOUNTERED DIFFICULTIES IN SEATING THE PROSTHESIS INTO POSITION. DURING THE IMPLANTATION ATTEMPT, THE NURSING STAFF OBSERVED A MISMATCH BETWEEN THE SERIAL NUMBER ON THE ID TAG ATTACHED TO THE PROSTHESIS AND THE SERIAL NUMBERS ON THE OUTER PACKAGING LABELS. THIS DISCREPANCY WAS PROMPTLY BROUGHT TO THE SURGEON¿S ATTENTION. DUE TO CONCERNS REGARDING BOTH THE SEATING DIFFICULTY AND THE SERIAL NUMBER MISMATCH, THE DECISION WAS MADE TO ABANDON THE IMPLANTATION OF THE DEVICE. IT WAS REPORTED THAT THE ISSUE RESULTED IN A SIGNIFICANT EXTENSION OF THE SURGICAL PROCEDURE¿ESTIMATED BETWEEN 40 AND 60 MINUTES¿WITHOUT ADVERSE EFFECTS ON THE PATIENT. BASED ON THE MEDICAL ASSESSMENT, THE DIFFICULTY IN POSITIONING THE PROSTHESIS WAS ATTRIBUTED PRIMARILY TO THE PATIENT¿S COMPLEX ANATOMY. HOWEVER, THE LABELLING INCONSISTENCY RAISED CONCERNS ABOUT THE POTENTIAL USE OF AN INCORRECTLY SIZED DEVICE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22078038 ↗
Other HEART-VALVE, MECHANICAL devices
- On-X Mitral Heart Valve with Conform-X Sewing Ring ONXMC-25/33On-X Life Technologies, Inc. · Heart-Valve, Mechanical1 recall1 death34 reports
- SJM Regent™ AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths70 reports
- SJM Regent™ AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL5 deaths66 reports
- SJM Regent™ 23AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths44 reports
- CARBOMEDICS SUPRA-ANNULAR (TOP HAT) S5-021Corcym Srl · HEART-VALVE, MECHANICAL7 deaths37 reports
- Regent™ 21AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths35 reports
- Regent™ 23AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL2 deaths33 reports
- Regent™ 19AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL31 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page