Delta Dual Mobility System 5566.50.420Recalls & reported problems
Limacorporate SPA · Mobile Liner Dia. 42 mm for Head Dia. 28 mm · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08033390012447), received between Oct 9, 2024 and Oct 9, 2024 — classified as 1 injury.
The most frequently reported specific device problem is “Degraded” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Degraded1
Patient problems
- Limb Pain1
- Loss of Range of Motion1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 9, 2024Degraded; Degraded
HIP REVISION SURGERY PERFORMED ON (B)(6) 2024, DUE TO WEAR OF THE MOBILE LINER ØINT 28 MM Ø42 MM (PRODUCT CODE 5566.50.420, LOT #1316292 - STER. 1400084). ACCORDING TO THE RECEIVED INFORMATION, THE PATIENT FELT STIFFNESS AND LOSS OF RANGE OF MOTION, AND THE PATIENT WENT FOR A CHECKUP. SHE HAD PAIN FOR A COUPLE OF WEEKS. IT WAS REPORTED THAT SINCE THE SURGEON IMPLANTED A LIMA DUAL MOBILITY LINER INTO A COMPETITOR'S CUP (OFF LABEL PROCEDURE), THE POLY LINER WORN DOWN OVER TIME. THE FOLLOWING DEVICES WERE EXPLANTED: · MOBILE LINER ØINT 28 MM Ø42 MM (PRODUCT CODE 5566.50.420, LOT #1316292 - STER. 1400084) · FEMORAL MODULAR HEAD - M Ø28MM (PRODUCT CODE 5010.42.282, LOT #1480074 - STER. 1400030) THE SURGEON REPLACED THE WORN LINER WITH A NEW COMPETITOR'S LINER AND A SLEEVE AND HEAD FROM ANOTHER COMPETITOR. THE FEMORAL COMPONENTS (LIMA'S REVISION STEM AND NECK) REMAINED IN SITU. PREVIOUS SURGERY TOOK PLACE ON (B)(6) 2014 (IT WAS A PRIMARY). PATIENT IS A FEMALE, 52 YEARS OLD. NO COMORBIDITIES ARE KNOWN. EVENT HAPPENED IN AUSTRALIA.
Patient problems: Limb Pain; Loss of Range of Motion
MAUDE report 20406645 ↗
Other Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented devices
- BIOLOX DELTA 1365-32-310Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented551 reports
- PINNACLE ALTRX 1221-36-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented481 reports
- BIOLOX DELTA 1365-32-320Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death314 reports
- BIOLOX DELTA 1365-36-720Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death189 reports
- DJO SURGICAL 400-03-362Encore Medical, L.P. · Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented187 reports
- Anthology 71365705Smith & Nephew, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented176 reports
- BIOLOX DELTA 1365-40-710Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented170 reports
- PINNACLE GRIPTION 1217-32-054Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented169 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page