Straight Broach HandleRecalls & reported problems
Limacorporate SPA · Straight Broach Handle M2 Connection · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08033390098311), received between May 30, 2024 and May 30, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Mechanical Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Mechanical Problem1
Patient problems
- Bone Fracture(s)1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 30, 2024Mechanical Problem; Mechanical Problem
DURING A HIP SURGERY PERFORMED ON (B)(6) 2024, IT WAS REPORTED THAT THERE WAS NO HANDLE IN THE INSTRUMENT SET FOR THE DIRECT ANTERIOR APPROACH (DAA). THE SURGEON DECIDED TO USE THE STRAIGHT BROACH HANDLE (PRODUCT CODE 9095.11.005, LOT #21AE019) FOR RASPING. DURING THE RASPING, THE HANDLE WAS REMOVED TO SEE IF THE RASP SIZE WAS APPROPRIATE, AND IMAGES WERE CHECKED. WHEN HE TRIED TO ENGAGE THE HANDLE INTO THE RASP TO REMOVE IT, DIFFICULTIES WERE EXPERIENCED, AND THE CALCAR AREA WAS OVERLOADED RESULTING IN BONE FRACTURE. INSTEAD OF THE PLANNED MASTER SL FEMORAL STEM, THE H-MAX C IMPLANT WAS USED TO COMPLETE THE SURGERY. THE CEMENTED STEM WAS FIXED WITHOUT PROBLEM ON THE FRACTURE AREA, AND A BIPOLAR HEAD WAS THEN IMPLANTED. THE SURGERY WAS COMPLETED WITHOUT PROBLEM ON FIXATION, BUT DUE TO THE EVENT THE SURGICAL TIME WAS EXTENDED FOR ABOUT 20 MINUTES. EVENT HAPPENED IN JAPAN.
Patient problems: Bone Fracture(s)
MAUDE report 19422446 ↗
Other Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented devices
- BIOLOX DELTA 1365-32-310Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented551 reports
- PINNACLE ALTRX 1221-36-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented481 reports
- BIOLOX DELTA 1365-32-320Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death314 reports
- BIOLOX DELTA 1365-36-720Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death189 reports
- DJO SURGICAL 400-03-362Encore Medical, L.P. · Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented187 reports
- Anthology 71365705Smith & Nephew, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented176 reports
- BIOLOX DELTA 1365-40-710Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented170 reports
- PINNACLE GRIPTION 1217-32-054Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented169 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page