PHYSICA TT 6521.14.050Recalls & reported problems
Limacorporate SPA · Physica TT - Ti6Al4V EBM - Fixed Tibial Plate #5 Uncemented · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08033390169912), received between May 21, 2026 and May 21, 2026 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Implant Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 21, 2026Adverse Event Without Identified Device or Use Problem
ON (B)(6) 2025 REVISION OF KNEE PROTHESIS DUE TO SINTERING OF PHYSICA TT FIX. TIBIAL TRAY #5 (PRODUCT CODE: 6521.14.050, LOT: 2211436 - STER: (B)(4). DURING REVISION THE TOTAL PRIMARY KNEE HAS BEEN CHANGED TO A ROTATING HINGED KNEE. PREVIOUS SURGERY WAS PERFORMED ON (B)(6) 2023. DURING ONE YEAR-CONTROL ONLY MINOR RADIOLOGIC SIGNS OF SINTERING SHOWED UP. INCREASING SINTERING WITHIN THE SECOND YEAR OF POST-OP. PATIENT DID NOT REPORT ANY TRAUMA. PRODUCT CODES AND LOT NUMBERS OF THE OTHER DEVICES IMPLANTED ON THE FIRST SURGERY ON 2023: PHYSICA TT FIX. TIBIAL TRAY #5 (PRODUCT CODE: 6521.14.050, LOT: 2211436 - STER: (B)(4), PS FEMORAL COMPONENT #5 LEFT (PRODUCT CODE: 6515.10.550, LOT: 2222424 - STER: (B)(4), PHYSICA PS TIBIAL LINER #5 (PRODUCT CODE: 6535.50.511, LOT: 22BC069 - STER: (B)(4), PHYSICA PS - FEMORAL PEG (PRODUCT CODE: 6515.09.900, LOT: 2313310 - STER: (B)(4). PATIENT: FEMALE, 75 YEARS OLD, APPROXIMATE HEIGHT 1.65(M), APPROXIMATE WEIGHT 58 (KG), ACTIVE LEVEL, NO SMOKING. EVENT OCCURRED IN AUSTRIA.
Patient problems: Implant Pain
MAUDE report 25238766 ↗
Other Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices
- ATTUNE 1506-00-005Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER589 reports
- ATTUNE 1506-00-004Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER580 reports
- JOURNEY 74012812Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER502 reports
- JOURNEY 74011856Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER438 reports
- PERSONA™ 42-5099-094-00Zimmer, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER406 reports
- JOURNEY 74011857Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER388 reports
- ATTUNE 1506-00-007Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER288 reports
- ATTUNE 1506-00-003Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page